The article introduces the µTongue (microfluidics-on-a-tongue) device for functional taste cell imaging in vivo by integrating microfluidics into an intravital imaging window on the tongue.
Intravital fluorescence microscopy is a tool used widely to study multicellular dynamics in a live animal. However, it has not been successfully used in the taste sensory organ. By integrating microfluidics into the intravital tongue imaging window, the µTongue provides reliable functional images of taste cells in vivo under controlled exposure to multiple tastants. In this paper, a detailed step-by-step procedure to utilize the µTongue system is presented. There are five subsections: preparing of tastant solutions, setting up of a microfluidic module, sample mounting, acquiring functional image data, and data analysis. Some tips and techniques to solve the practical issues that may arise when using the µTongue are also presented.
The intravital fluorescence microscope is used widely to study the spatiotemporal dynamics on living tissues. Researchers are rapidly developing genetically encoded sensors that provide specific and sensitive transformations of the biological processes into fluorescence signals – which can be recorded readily using fluorescence microscopes that are widely available1,2. Although most internal organs in rodents have been investigated using the microscope, its successful application to the tongue has not yet been successful3.
Previous studies on the calcium imaging of taste cells were conducted ex vivo by thin-sectioning a tongue tissue to obtain circumvallate taste buds4,5,6 or by peeling off the taste epithelium to obtain fungiform taste buds7,8. The preparation of these samples was inevitably invasive, thus the natural microenvironments such as nerves innervation, permeability barriers, and blood circulation, were largely perturbed. The first intravital tongue imaging window was reported in 2015 by Choi et al., but reliable functional recording was not achievable because of the movement and optical artifacts caused by fluidic tastant stimuli9.
Recently, microfluidics-on-a-tongue (µTongue) was introduced10. This device integrates a microfluidic system with an imaging window on the mouse tongue. By attaining a quasi-steady-state flow of tastant stimuli throughout the imaging period, artifacts from fluidic motion could be minimized (Figure 1). The input port is fed by a series of multichannel pressure controllers, whereas the output port is connected to a syringe pump, which maintains 0.3 mL/min. Additionally, optical artifacts caused by the difference in refractive indices of tastant solutions were minimized by ratiometric analysis introducing a calcium-insensitive indicator (tdTomato) as well as the calcium indicator (GCaMP6)11. This design provided microscopic stability of taste cells in vivo even with abrupt switching between fluidic channels. Consequently, the µTongue implement a reliable functional screening of multiple tastants to the mouse taste buds in vivo.
In this protocol, the experimental procedures are explained in detail for calcium imaging of the mouse fungiform taste buds in vivo using µTongue. First, the preparation of artificial saliva and tastant solutions is described. Second, the setting up of the microfluidic system to achieve the quasi-steady-state flow is introduced. Third, the procedures used to mount the mouse tongue on the µTongue to permit image acquisition are delineated. Lastly, each step for image analysis, including correction of lateral motion artifacts and ratiometry, is specified. This protocol can be adapted readily to any research laboratory with a mouse facility and a two-photon microscope or equivalent equipment.
All surgical procedures were approved by the Institutional Animal Care and Use Committee (IACUC) of Sungkyunkwan University and Seoul National University.
1. Preparation of solutions: artificial saliva and tastants
2. Preparation of the microfluidic system
NOTE: Tastants were delivered to the mouse tongue using a pressurized multichannel fluidic delivery system (refer Figure 1 and Table of Materials).
3. Mouse preparation for in vivo imaging (Figure 2).
NOTE: All animal preparations were carried out during the daytime under aseptic conditions on a laboratory workbench.
4. Imaging acquisition
5. Image analysis (Figure 3)
The Pirt-GCaMP6f-tdTomato mouse was used to obtain a taste bud image. The surface of the mouse tongue was covered with autofluorescent filiform papillae. Taste buds are spread sparsely over the surface of the tongue (Figure 4A). The images of the taste bud and its structure were acquired using three different filter detectors. Using the 607/70 nm filter set, the tdTomato signal from the taste cells was obtained for ratiometric analysis (Figure 4B). Using the 525/50 nm filter set, the GCaMP signal from the taste cells and blood vessels that surround the taste bud were acquired (Figure 4B). Using the 447/60 nm filter set, the collagen connective tissue, which structurally supports the taste bud, was acquired (Figure 4B).
After acquiring the images of the taste bud and relative structures, in vivo calcium imaging was carried out using the protocol. The Pirt-GCaMP6f-tdTomato mouse was used to screen on taste cells (Figure 5A)16. Taste cells responded repeatedly to their respective taste stimuli (Figure 5B). Taste cells were considered to have reacted to the tastant when they met the conditions presented in protocol 5.1.4. In this trial, cell 2 responded to both sweet and umami tastants. The result is consistent with previous research observing cellular activity using electrophysiology17. Cell 3 responded to both 400 mM NaCl and 400 mM NaCl under amiloride. It implicates that cell 3 have used an ENaC independent pathway for the response to salty taste. The taste bud in this experiment did not include a cell responding to sour tastes. The screening of taste cells was carried out under stable imaging conditions, and each taste cell showed a repeatable response to a distinct type of taste.
Figure 1: The µTongue, a microfluidics-based functional imaging platform. (A) Pressurized fluidic delivery system. (i) The pressure regulator of the fluidic system is connected to the external air source. The pressure of the air source is adjusted between 30-50 psi before entering the pressure regulator. (ii) Air pressure from the regulator is approximately 0.4 psi. (iii) Reservoirs containing artificial saliva and different taste solutions are connected to the output of the air pressure regulator. (iv) Each reservoir converges to a manifold that is connected to the input port of the µTongue. (v) A syringe pump is connected to the output of the µTongue and controls the flow. (B) The µTongue, a microfluidics-based functional imaging platform. The name of each part is specified in the figure. (i) Mouse preparation board. (ii) Fluidic system setup board. Please click here to view a larger version of this figure.
Figure 2: Sequential description of mouse preparation. Important steps in the mouse preparation are shown. (A) Retro-orbital injection of TRITC-dextran. (B) Process of attachment of a head fixer to the mouse skull is shown. The head skin and periosteum are cleared. Adhesive glue and dental glue are used for attachment. (C) The head fixer on the mouse skull is screwed onto the mouse preparation board. (D) Procedure of mounting a tongue on the bottom unit of the µTongue. An instant adhesive is used for tongue fixation. The tongue is cleaned using a wet cotton swab and covered with wet paper tissues to prevent dryness. (E) Curved washers are applied to both ends of the bottom unit of the µTongue. (F) A piece of twisted paper tissue is placed in the mouse oral cavity. (G) Mouse preparation board is mounted on the microscope stage and screwed tightly to ensure stable imaging conditions. (H) The µTongue is placed on the tongue. An objective lens is adjusted over the imaging window. Please click here to view a larger version of this figure.
Figure 3: Image analysis. (A) An RGB image is converted from each single-color image. Scale bar, 10 µm. (B) Image registration using a conducted custom code. (C) GUI of the custom code. (i) Input location for the frame rate. The default frame rate is 0.16 s/frame. (ii) Buttons to draw ROIs. (iii) The area in which the loaded image is shown. (iv) The calcium signal of the ROI selected is shown as a green trace, whereas the calcium-insensitive signal of the ROI selected is shown as a red trace. (v) Ratiometric analysis and ΔF/F are calculated automatically. The ΔF/F graph is presented in magenta. (vi) Buttons for image loading. New Analysis is for loading an RGB converted image. Load Data is for loading an image that has already undergone registration. (vii) The Save Trace button is to keep the ΔF/F graph and the ROI selected at viii. The Delete Trace button is to remove ΔF/F graph from viii. (viii) Saved calcium traces are shown. (ix) Area to fill in the file name. The Finish button is to extract data and save them in the same directory of the code. Please click here to view a larger version of this figure.
Figure 4: The surface of the mouse tongue and a taste bud in the fungiform papillae. (A) The surface of the mouse tongue is captured in a large field. A taste bud keratinized filiform papillae, and the collagen structure are shown. Each structure is indicated using different colors: magenta, yellow, and green, respectively. Scale bar, 100 µm. (B) A taste bud from (A) is magnified in and captured using three different emission filter detectors. The filiform papillae, in yellow, are captured using a 525/50 nm detector. This structure is observed from the very surface of the tongue up to ~25 µm in depth. GCaMP signals in green and tdTomato signals in red represent the taste cells. These signals are detected by 525/50 and 607/70 nm detectors, respectively. Rhodamine dextran representing blood circulation is captured at both 525/50 and 607/70 nm detectors. The collagen structure shown in cyan blue is acquired by 447/60 nm detectors. The last picture shows all the previous images merged. Scale bar, 20 µm. Please click here to view a larger version of this figure.
Figure 5: Taste screeningof a Pirt-GCaMP6f-tdTomato mouse in vivo. (A) A representative taste bud of the Pirt-GCaMP6f-tdTomato mouse. The image is shown as an intensity-based pseudo-color. Dashed lines demarcate each taste cell. The brightness of each taste cell depends on the expression of the fluorescent protein and the depth of the taste cell location. Scale bar, 10 µm. (B) The calcium trace of each taste cell for the five basic taste stimuli. Every repeated trial is shown in gray on the back and the averaged trace is presented above each trial. Colored traces are defined as responsive whereas black traces are defined as non-responsive. Each color represents a different taste. Salty(L) represents low salty, with a mixture of 400 mM NaCl and 50 µM amiloride used for taste stimulation. Salty(H) represents high salty, with 400 mM NaCl used for stimulation. Taste stimulation is shown as a gray box on the back of each calcium trace. Please click here to view a larger version of this figure.
Described here is a detailed protocol to apply µTongue to the investigation of functional activities of taste cells in vivo. In this protocol, the functional imaging on the taste cells using genetically encoded calcium indicators is performed. In addition to the use of transgenic mice, the electrophoretic loading of calcium dyes (or voltage sensing dyes) onto the taste cells can be an alternative option.
All the taste solutions less than 1.336 of refractive index were used in this experiment. Although µTongue provides a stable fluidic delivery and the ratiometric analysis ameliorates imaging artifacts, it will be challenging for the researchers to use a higher concentration of tastant (e.g., >100 mM sucrose with refractive index in 1.338). The large difference in refractive index between artificial saliva and taste solution shifts the image focal plane more than the compensation range by the post-image process. Empirically, a certain range of refractive index of taste solution (less than 1.336) that allows stable cellular imaging in real-time is obtained.
For researchers experienced in fluorescence imaging and animal handling, this protocol can be learned readily over repeated practice. However, it contains critical steps, which often impede successful data acquisition. First, once externalized from the oral civility, the tongue should be kept moist with artificial saliva to preserve the natural mucosal microenvironment. Second, blood circulation around the taste bud should be intact, to maintain a physiologic supply of oxygen, nutrients, and blood-borne factors.
The authors have nothing to disclose.
This work was supported by the Institute of Basic Science (IBS-R015-D1), the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (No. 2019M3A9E2061789), and by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (No. 2019M3E5D2A01058329). We are grateful to Eunsoo Kim and Eugene Lee for their technical assistance.
acesulfame K | Sigma Aldrich | 04054-25G | Artificial saliva / tastant |
calcium chloride solution | Sigma Aldrich | 21115-100ML | Artificial saliva / tastant |
citric acid | Sigma Aldrich | C0759-100G | Artificial saliva / tastant |
cycloheximide | Sigma Aldrich | 01810-5G | Artificial saliva / tastant |
denatonium | Sigma Aldrich | D5765-5G | Artificial saliva / tastant |
Dental glue | Denkist | P0000CJT-A2 | Animal preparation |
Image J | NIH | ImageJ | Data analysis |
IMP | Sigma Aldrich | 57510-5G | Artificial saliva / tastant |
Instant adhesive | Loctite | Loctite 4161, Henkel | Animal preparation |
K2HPO4 | Sigma Aldrich | P3786-100G | Artificial saliva / tastant |
KCl | Sigma Aldrich | P9541-500G | Artificial saliva / tastant |
Ketamine | Yuhan | Ketamine 50 | Animal preparation |
KH2PO4 | Sigma Aldrich | P0662-25G | Artificial saliva / tastant |
KHCO3 | Sigma Aldrich | 237205-500G | Artificial saliva / tastant |
MATLAB | Mathwork | MATLAB | Data analysis |
MgCl2 | Sigma Aldrich | M8266-100G | Artificial saliva / tastant |
MPG | Sigma Aldrich | 49601-100G | Artificial saliva / tastant |
Mutiphoton microscope | Thorlab | Bergamo II | Microscope |
NaCl | Sigma Aldrich | S3014-500G | Artificial saliva / tastant |
NaHCO3 | Sigma Aldrich | 792519-500G | Artificial saliva / tastant |
Objective | Nikon | N16XLWD-PF | Microscope |
Octaflow | ALA Scientific Instruments | OCTAFLOW II | Fluidic control |
PC | LG | Lg15N54 | Fluidic control |
PH meter | Thermoscientific | ORION STAR AZ11 | Artificial saliva / tastant |
Phosphate-buffered saline | Sigma Aldrich | 806562 | Artificial saliva / tastant |
quinine | Sigma Aldrich | Q1125-5G | Artificial saliva / tastant |
Syringe pump | Havard Apparatus | PHD ULTRA 4400 | Fluidic control |
TRITC-dextran | Sigma Aldrich | 52194-1G | Animal preparation |
Ultrafast fiber laser | Toptica | FFultra920 01042 | Microscope |
Xylazine | Bayer Korea | Rompun | Animal preparation |