Özet

Caratterizzare lontano infrarosso Emissioni laser e la misurazione delle loro frequenze

Published: December 18, 2015
doi:

Özet

We describe the generation of far-infrared radiation using an optically pumped molecular laser along with the measurement of their frequencies with heterodyne techniques. The experimental system and techniques are demonstrated using difluoromethane (CH2F2) as the laser medium whose results include three new laser emissions and eight measured laser frequencies.

Abstract

La generazione e successiva misura della radiazione all'infrarosso lontano ha trovato numerose applicazioni in spettroscopia ad alta risoluzione, radio astronomia, e di imaging Terahertz. Per circa 45 anni, la generazione di coerenza, radiazioni all'infrarosso lontano è stato realizzato utilizzando il laser molecolare pompaggio ottico. Una volta rilevata la radiazione laser all'infrarosso lontano, le frequenze di queste emissioni laser sono misurate usando una tecnica eterodina tre laser. Con questa tecnica, la frequenza sconosciuta del laser molecolare pompaggio ottico è mescolato con la differenza di frequenza tra due frequenze di riferimento, stabilizzati infrarossi. Queste frequenze di riferimento vengono generati da laser di biossido di carbonio indipendenti, ciascuna stabilizzato utilizzando il segnale di fluorescenza da una cella di riferimento bassa pressione esterna. Il battito risultante tra le note e sconosciute frequenze laser è monitorato da un punto di contatto diodo rivelatore metallo-isolante-metallo la cui uscita è osservato su una specificaanalizzatore trum. La frequenza di battimento tra queste emissioni laser viene successivamente misurata e combinato con le frequenze di riferimento noti per estrapolare la frequenza del laser lontano infrarosso sconosciuta. La risultante di un sigma incertezza frazionata per frequenze laser misurata con questa tecnica è di ± 5 parti in 10 7. Determinare accuratamente la frequenza delle emissioni laser lontano infrarosso è critico in quanto sono spesso utilizzati come riferimento per altre misure, come in alto indagini spettroscopiche -Risoluzione dei radicali liberi con laser a risonanza magnetica. Nell'ambito di questa indagine, difluorometano, CH 2 F 2, è stato utilizzato come mezzo di laser lontano infrarosso. In tutto, otto frequenze laser lontano infrarosso sono stati misurati per la prima volta con frequenze che vanno da 0.359 al 1.273 THz. Tre di queste emissioni laser sono stati scoperti durante questa indagine e presentate con la loro pressione di esercizio ottimale, polarizzazione rispetto al CO 2 </sub> pompa di laser, e la forza.

Introduction

La misurazione delle frequenze laser lontano infrarosso fu eseguita da Hocker e collaboratori nel 1967. Hanno misurato le frequenze per i 311 e 337 micron emissioni dal-scarico diretto laser acido cianidrico mescolandoli con armoniche di ordine elevato di un segnale a microonde in un diodo al silicio 1. Per misurare frequenze superiori, una catena di laser e dispositivi di miscelazione armonici sono stati utilizzati per generare le armoniche laser 2. Alla fine due stabilizzato anidride carbonica (CO 2) laser sono stati scelti per sintetizzare la differenza necessaria frequenze 3,4. Oggi, frequenze laser all'infrarosso lontano fino a 4 THz può essere misurata con questa tecnica utilizzando solo la prima armonica della frequenza differenza generato da due stabilizzate CO 2 laser di riferimento. Elevate emissioni laser frequenza possono anche essere misurati usando la seconda armonica, come le emissioni laser 9 THz dal isotopologhi metanolo CHD 2 OH e CH 3 </sub> 18 OH. 5,6 Nel corso degli anni, la misurazione accurata delle frequenze laser ha inciso una serie di esperimenti scientifici 7,8 e permesso l'adozione di una nuova definizione del metro dalla Conferenza Generale dei Pesi e delle Misure a Parigi nel 1983. 9 11

Eterodina tecniche, come quelle descritte, sono state estremamente utile nella misurazione delle frequenze laser lontano infrarosso generati dai laser pompati otticamente molecolari. Dalla scoperta del laser molecolare pompaggio ottico da Chang e ponti 12, migliaia di pompaggio ottico emissioni laser lontano infrarosso sono stati generati con una varietà di mezzi laser. Ad esempio, difluorometano (CH 2 F 2) e suoi isotopologhi generano oltre 250 emissioni laser quando pompaggio ottico da un laser CO 2. Loro lunghezze d'onda vanno da circa 95,6-1714,1 micron 13. </sup> 15 Quasi il 75% di queste emissioni laser hanno avuto le loro frequenze misurate, mentre molti sono stati assegnati spettroscopicamente 16-18.

Questi laser, e le loro frequenze, esattamente misurata, hanno svolto un ruolo cruciale nel progresso della spettroscopia ad alta risoluzione. Essi forniscono informazioni importanti per gli studi spettrali infrarossi dei gas laser. Spesso queste frequenze laser sono utilizzati per verificare l'analisi degli spettri infrarossi e lontano infrarosso perché forniscono connessioni tra i livelli eccitati stato vibrazionale che spesso sono direttamente accessibili da spettri di assorbimento 19. Essi servono anche come fonte di radiazione primaria per gli studi che indagano transitori, i radicali liberi di breve durata con la tecnica laser a risonanza magnetica 20. Con questa tecnica estremamente sensibile, rotazione e ro-vibrazionale spettri Zeeman negli atomi paramagnetici, molecole e ioni molecolari può essere recorded e analizzato con la capacità di indagare le velocità di reazione utilizzate per creare questi radicali liberi.

In questo lavoro, un laser molecolare pompaggio ottico, mostrato videodan figura 1, è stato utilizzato per generare radiazione laser all'infrarosso lontano da difluorometano. Questo sistema è composto da un onda continua (cw) CO 2 laser di pompa ed una cavità laser lontano infrarosso. Uno specchio interna alla cavità laser lontano infrarosso reindirizza la radiazione laser CO 2 nel tubo di rame lucido, subendo ventisei riflessioni prima di terminare alla fine della cavità, spargendo qualsiasi radiazione di pompa residua. Pertanto, il mezzo di laser lontano infrarosso è eccitato con una geometria di pompaggio trasversale. Per generare azione del laser, diverse variabili vengono regolati, alcuni simultaneamente, e tutte sono poi ottimizzati volta radiazione laser è osservata.

In questo esperimento, la radiazione laser all'infrarosso lontano è monitorata da un metallo-insutore-metallo (MIM) punto di contatto diodo rivelatore. Il rivelatore diodo MIM è stato usato per misure di frequenza laser dal 1969. 21 23 In misure di frequenza laser, il rivelatore diodo MIM è un mixer armonico tra due o più sorgenti di radiazione incidente sul diodo. Il rivelatore diodo MIM è costituito da un filo di tungsteno affilato contatto con un base di nickel otticamente lucidato 24. La base nichel ha un naturale strato di ossido sottile che è lo strato isolante.

Una volta che una emissione laser è stato rilevato, la sua lunghezza d'onda, polarizzazione, forza e pressione di esercizio ottimizzati sono stati registrati mentre la sua frequenza è stata misurata utilizzando tre laser eterodina tecnica 25 27 secondo il metodo descritto originariamente in Ref. 4. La Figura 2 mostra il laser molecolare pompaggio ottico con due ulteriori cw CO 2 laser di riferimento avente sta frequenza indipendentisistemi bilization che utilizzano il tuffo Agnello nel segnale di fluorescenza 4.3 micron da una cella di riferimento, a bassa pressione esterna 28. Questo manoscritto descrive il processo utilizzato per la ricerca di emissioni laser all'infrarosso lontano e metodo per la stima loro lunghezza d'onda e nel determinare con precisione la loro frequenza. Specifiche relative alla tecnica eterodina tre laser così come i vari componenti ei parametri operativi del sistema possono essere trovati in riferimento Tabella A con riferimenti 4, 25-27, 29 e 30.

Protocol

1. Pianificazione di Esperimenti Condurre uno studio della letteratura per valutare il lavoro preliminare eseguito utilizzando il mezzo di laser di interessi, che per questo esperimento è CH 2 F 2. Identificare tutte le emissioni laser noti insieme a tutte le informazioni sulle linee, come la loro lunghezza d'onda e la frequenza. Diverse indagini di emissioni laser noti sono disponibili 13,31 – 37. Compilare tutte le indagini spettroscopich…

Representative Results

Come accennato, la frequenza riportata di emissione laser lontano infrarosso è una media di almeno dodici misure effettuate con almeno due diversi insiemi di CO linee laser 2 di riferimento. La Tabella 2 illustra i dati registrati per l'emissione 235.5 micron laser utilizzando la 9 P 04 CO 2 laser della pompa. Per questa emissione laser lontano infrarosso, sono state registrate quattordici misurazioni individuali della frequenza di battimento. La prima serie di misure…

Discussion

Ci sono diversi passaggi critici all'interno del protocollo che richiedono una discussione supplementare. Quando si misura la lunghezza d'onda del laser all'infrarosso lontano, come descritto nel passaggio 2.5.3, è importante garantire la stessa modalità dell'emissione laser lontano infrarosso viene utilizzato. Modalità multiple di una lunghezza d'onda laser lontano infrarosso (cioè, TEM 00, TEM 01, etc.) possono essere generati all'interno della cavità laser e…

Açıklamalar

The authors have nothing to disclose.

Acknowledgements

This work was supported in part by the Washington Space Grant Consortium under Award NNX10AK64H.

Materials

Vacuum pump Leybold Trivac D4A HE-175 oil; Quantity = 3
Vacuum pump Leybold Trivac D8B or D16B Fomblin Fluid; Quantity = 1 of each
Vacuum pump Leybold Trivac D25B HE-175 oil; Quantity = 1
Optical chopper with controller Stanford Research Systems SR540
Lock-in amplifier Stanford Research Systems SR830
Spectrum analyzer Agilent E4407B ESA-E Series, 9 kHz to 26.5 GHz Spectrum Analyzer
Amplifier  Miteq AFS-44 Provides amplification of signals between 2 and 18 GHz. The amplifier is powered by a Hewlett Packard triple output DC power supply, model E3630A.
Amplifier  Avantek AWL-1200B Provides amplification of signals less than 1.2 GHz.
Power supply Hewlett Packard E3630A Low voltage DC power supply for amplifier.
Power supply Glassman KL Series High voltage power supply for the CO2 lasers; Quantity = 2; negative polarity
Power supply Fluke 412B High voltage power supply used with the NIST Asymmetric HV Amp
Detector Judson Infrared Inc J10D For fluorescence cell; Quantity = 2
CO2 laser spectrum analyzer Optical Engineering  16-A Currently sold by Macken Instruments Inc.
Thermal imaging plates with UV light Optical Engineering  Primarily used for aligning the CO2 reference lasers. Currently sold by Macken Instruments Inc.
Resistors Ohmite  L225J100K 100 kW, 225 W. Between 4 to 6 resistors are used in each ballast system. Each CO2 laser has its own ballast system. Fans are used to cool the resistors.
HV relay, SPDT CII Technologies H-17 Quantity = 3; one for each CO2 laser
Amplifier  Princeton Applied Research PAR 113 Used with fluorescence cell; Quantity = 2
Oscilloscope Tektronix 2235A Similar models are also used; Quantity = 2
Oscilloscope/Differential amplifier Tektronix 7903 oscilloscope with 7A22 differential amplifier
Power meter with sensor Coherent 200 For use below 10 W.  This is the power meter shown in Figure 2.
Power meter with sensor Scientech, Inc Vector S310 For use below 30 W
Multimeter Fluke 73III Similar models are also used; Quantity = 3
Data acquisition National Instruments NI cDAQ 9174 chassis with NI 9223 input module Uses LabVIEW software
Simichrome polish Happich GmbH Polish for the Nickel base used in the MIM diode detector. Although the Nickel base can be used immediately after polishing, a 12 hour lead time is typically recommended.
Pressure gauge Wallace and Tiernan 61C-1D-0050 Series 300; for CO2 laser; Quantity = 3
Pressure gauge with controller Granville Phillips Series 375 For far-infrared laser
Zirconium Oxide felt Zircar Zirconia ZYF felt Used as a beam stop
Zirconium Oxide board Zircar Zirconia ZYZ-3 board Used as a beam stop; Quantity = 4
Teflon sheet Scientific Commodities, Inc BB96312-1248 1/32 inch thick; used for the far-infrared laser output window
Polypropylene C-Line sheet protectors 61003 used for the far-infrared laser output window
Vacuum grease Apiezon
Power supply Kepco NTC 2000 PZT power supply
PZT tube Morgan Advanced Materials 1 inch length, 1 inch outer diameter, 0.062 inch thickness, reverse polarity (positive voltage on outside); Quantity = 3
ZnSe (AR coated) II-VI Inc CO2 laser window (Quantity = 3), lens, and beam splitter (Quantity 3)
NaCl window Edmond Optics Quantity = 1
CaF window Edmond Optics Quantity = 2
Laser mirrors and gratings Hyperfine, Inc Gold-coated; includes positioning mirrors
Glass laser tubes and reference cells Allen Scientific Glass
MIM diode detector Custom Microwave, Inc
Diğer Other materials include magnetic bases, base plates, base clamps, XYZ translation stage, etc.

Referanslar

  1. Hocker, L. O., Javan, A., Ramachandra Rao, D., Frenkel, L., Sullivan, T. Absolute frequency measurement and spectroscopy of gas laser transitions in the far infrared. Appl. Phys. Lett. 10 (5), 147-149 (1967).
  2. Wells, J. S., Evenson, K. M., Day, G. W., Halford, D. Role of infrared frequency synthesis in metrology. Proc. IEEE. 60 (5), 621-623 (1972).
  3. Whitford, B. G., Siemsen, K. J., Riccius, H. D., Baird, K. A. New frequency measurements and techniques in the 30-THz region. IEEE Trans. Instrum. Meas. 23 (4), 535-539 (1974).
  4. Petersen, F. R., et al. Far infrared frequency synthesis with stabilized CO2 lasers: Accurate measurements of the water vapor and methyl alcohol laser frequencies. IEEE J. Quantum Elect. 11 (10), 838-843 (1975).
  5. Uranga, C., Connell, C., Borstad, G. M., Zink, L. R., Jackson, M. Discovery and frequency measurement of short-wavelength far-infrared laser emissions from optically pumped 13CD3OH and CHD2OH. Appl. Phys. B. 88 (4), 503-505 (2007).
  6. Jackson, M., Milne, J. A., Zink, L. R. Measurement of optically pumped CH318OH laser frequencies between 3 and 9 THz. IEEE J. Quantum Elect. 47 (3), 386-389 (2011).
  7. Evenson, K. M., et al. Optically pumped FIR lasers: Frequency and power measurements and laser magnetic resonance spectroscopy. IEEE J. Quantum Elect. 13 (6), 442-444 (1977).
  8. Evenson, K. M., Jennings, D. A., Petersen, F. R. Tunable far-infrared spectroscopy. Appl. Phys. Lett. 44 (6), 576-577 (1984).
  9. Evenson, K. M., et al. Speed of light from direct frequency and wavelength measurements of the methane-stabilized laser. Phys. Rev. Lett. 29 (19), 1346-1349 (1972).
  10. BIPM. . Resolution 1. , 97-98 (1983).
  11. Giacomo, P. News from the BIPM. Metrol. 20 (1), 25-30 (1984).
  12. Chang, T. Y., Bridges, T. J. Laser action at 452, 496 and 541 µm in optically pumped CH3F. Opt. Commun. 1 (9), 423-426 (1970).
  13. Douglas, N. G., Walter, H. . Millimetre and Submillimetre Wavelength Lasers: A Handbook of CW Measurements. 61, (1989).
  14. Zerbetto, S. C., Vasconcellos, E. C. C., Zink, L. R., Evenson, K. M. 12CH2F2 and 13CH2F2 far-infrared lasers: New lines and frequency measurements. Int. J. Infrared Millim. Waves. 18 (12), 2301-2306 (1997).
  15. Jackson, M., Alves, H., Holman, R., Minton, R., Zink, L. R. New cw optically pumped far-infrared laser emissions generated with a transverse or ‘zig-zag’ pumping geometry. J. Infrared, Millim., Terahertz Waves. 35 (3), 282-287 (2014).
  16. Danielewicz, E. J., Button, K. J., Inguscio, M., Strumia, F. . The optically pumped difluoromethane far-infrared laser. Reviews of Infrared and Millimeter Waves. 2, 223-250 (1983).
  17. Deroche, J. C., Benichou, E. K., Guelachvili, G., Demaison, J. Assignments of submillimeter emissions in difluoromethane pumped by 12C18O2 and 12C18O2 lasers. Int. J. Infrared Millim. Waves. 7 (10), 1653-1675 (1986).
  18. Jackson, M., Zink, L. R., McCarthy, M. C., Perez, L., Brown, J. M. The far-infrared and microwave spectra of the CH radical in the v = 1 level of the X2Π. J. Mol. Spectrosc. 247 (2), 128-139 (2008).
  19. Zhao, S., Lees, R. M. CH318OH: Assignment of FIR laser lines optically pumped in the in-plane CH3-rocking band. J. Mol. Spectrosc. 168 (1), 67-81 (1994).
  20. Evenson, K. M., Saykally, R. J., Jennings, D. A., Curl, R. F., Brown, J. M. Far infrared laser magnetic resonance. Chemical and Biochemical Applications of Lasers. 5, 95-138 (1980).
  21. Hocker, L. O., Sokoloff, D. R., Daneu, V., Szoke, A., Javan, A. Frequency mixing in the infrared and far-infrared using a metal-to-metal point contact diode. Appl. Phys. Lett. 12 (12), 401-402 (1968).
  22. Daneu, V., Sokoloff, D., Sanchez, A., Javan, A. Extension of laser harmonic-frequency mixing techniques into the 9 μ region with an infrared metal-metal point-contact diode. Appl. Phys. Lett. 15 (12), 398-400 (1969).
  23. Jennings, D. A., Evenson, K. M., Knight, D. J. E. Optical Frequency Measurements. Proc. IEEE. 74 (1), 168-179 (1986).
  24. Zink, L. R. . Highly accurate molecular constants for CO, HF, HCl, OH, NaH, MgH, and O2: Rotational transition frequencies measured with tunable far infrared radiation [thesis]. , (1986).
  25. Xu, L. -. H., et al. Methanol and the optically pumped far-infrared laser. IEEE J. Quantum Elect. 32 (3), 392-399 (1996).
  26. Jackson, M., Zink, L. R., Garrod, T. J., Petersen, S., Stokes, A., Theisen, M. The generation and frequency measurement of short-wavelength far-infrared laser emissions. IEEE J. Quantum Elect. 41 (12), 1528-1532 (2005).
  27. Jackson, M., Smith, M., Gerke, C., Barajas, J. M. Measurement of far-infrared laser frequencies from methanol isotopologues. IEEE J. Quantum Elect. 51 (4), 1500105 (2015).
  28. Freed, C., Javan, A. Standing-wave saturation resonances in the CO2 10.6 μ transitions observed in a low-pressure room-temperature absorber gas. Appl. Phys. Lett. 17 (2), 53-56 (1970).
  29. DeShano, B., Olivier, K., Cain, B., Zink, L. R., Jackson, M. Using guide wavelengths to assess far-infrared laser emissions. J. Infrared, Millim., Terahertz Waves. 36 (1), 13-30 (2015).
  30. Jackson, M., Nichols, A. J., Womack, D. R., Zink, L. R. First laser action observed from optically pumped CH317OH. IEEE J. Quantum Elect. 48 (3), 303-306 (2012).
  31. Inguscio, M., Moruzzi, G., Evenson, K. M., Jennings, D. A. A review of frequency measurements of optically pumped lasers from 0.1 to 8 THz. J. Appl. Phys. 60 (12), R161-R191 (1986).
  32. Pereira, D., et al. A review of optically pumped far-infrared laser lines from methanol isotopes. Int. J. Infrared Millim. Waves. 15 (1), 1-44 (1994).
  33. Zerbetto, S. C., Vasconcellos, E. C. C. Far infrared laser lines produced by methanol and its isotopic species: A review. Int. J. Infrared Millim. Waves. 15 (5), 889-933 (1994).
  34. Moruzzi, G., Winnewisser, B. P., Winnewisser, M., Mukhopadhyay, I., Strumia, F. . Microwave, Infrared and Laser Transitions of Methanol: Atlas of Assigned Lines from 0 to 1258 cm-1. , (1995).
  35. Weber, M. J. . Handbook of Laser Wavelengths. , (1999).
  36. De Michele, A., et al. FIR laser lines from CH3OD: A review. Int. J. Infrared Millim. Waves. 25 (5), 725-734 (2004).
  37. De Michele, A., Carelli, G., Moruzzi, G., Moretti, A. Hydrazine far-infrared laser lines and assignments: a review. J. Opt. Soc. Am. B. 22 (7), 1461-1470 (2005).
  38. Moraes, J. C. S., et al. Experimental investigation of 13CD3OH infrared transitions by means of optoacoustic spectroscopy. Int. J. Infrared Millim. Waves. 13 (11), 1801-1823 (1992).
  39. Viscovini, R. C., Scalabrin, A., Pereira, D. Infrared optoacoustic spectroscopy of 13CD3OD around the 10R and 10P CO2 laser lines. Int. J. Infrared Millim. Waves. 17 (11), 1821-1838 (1996).
  40. Maki, A. G., Chou, C. C., Evenson, K. M., Zink, L. R., Shy, J. T. Improved molecular constants and frequencies for the CO2 laser from new high-J regular and hot-band frequency measurements. J. Mol. Spectrosc. 167 (1), 211-224 (1994).
  41. Douglas, N. G., Krug, P. A. CW laser action in ethyl chloride. IEEE J. Quantum Elect. 18 (10), 1409-1410 (1982).
  42. Schwaller, P., Steffen, H., Moser, J. F., Kneubühl, F. K. Interferometry of resonator modes in submillimeter wave lasers. Appl. Opt. 6 (5), 827-829 (1967).
  43. Steffen, H., Kneubühl, F. K. Resonator interferometry of pulsed submillimeter-wave lasers. IEEE J. Quantum Elect. 4 (12), 992-1008 (1968).
  44. Whitbourn, L. B., Macfarlane, J. C., Stimson, P. A., James, B. W., Falconer, I. S. An experimental study of a cw optically pumped far infrared formic acid vapour laser. Infrared Phys. 28 (1), 7-20 (1988).
  45. Belland, P., Véron, D., Whitbourn, L. B. Mode study, beam characteristics and output power of a cw 337 μm HCN waveguide laser. J. Phys. D: Appl. Phys. 8 (18), 2113-2122 (1975).
  46. Inguscio, M., Ioli, N., Moretti, A., Strumia, F., D’Amato, F. Heterodyne of optically pumped FIR molecular lasers and direct frequency measurement of new lines. Appl. Phys. B. 40 (3), 165-169 (1986).
  47. Carelli, G., et al. CH318OH: FIR laser line frequency measurements and assignments. Infrared Phys. Technol. 35 (6), 743-755 (1994).
  48. Pearson, J. C., Müller, H. S. P., Pickett, H. M., Cohen, E. A., Drouin, B. J. Introduction to submillimeter, millimeter and microwave spectral line catalog. J. Quant. Spectrosc. Radiat. Transf. 111 (11), 1614-1616 (2010).
  49. Ehasz, E. J., Goyette, T. M., Giles, R. H., Nixon, W. E. High-resolution frequency measurements of far-infrared laser lines. IEEE J. Quantum Elect. 46 (4), 474-477 (2010).
  50. Pearson, J. C., Drouin, B. J., Yu, S., Gupta, H. Microwave spectroscopy of methanol between 2.48 and 2.77 THz. J. Opt. Soc. Am. B. 28 (10), 2549-2577 (2011).
  51. Consolino, L., et al. Phase-locking to a free-space terahertz comb for metrological-grade terahertz lasers. Nat. Commun. 3, Article No. 1040 (2012).
  52. Bartalini, S., et al. Frequency-comb-assisted terahertz quantum cascade laser spectroscopy. Phys. Rev. X. 4 (2), 021006 (2014).
  53. Finneran, I. A., Good, J. T., Holland, D. B., Carroll, P. B., Allodi, M. A., Blake, G. A. Decade-spanning high-precision terahertz frequency comb. Phys. Rev. Lett. 114 (16), Article No. 163902 (2015).
  54. De Natale, P., et al. Quantum cascade laser THz metrology. Proc. SPIE.. , 93701D (2015).
  55. Dickinson, J. C., Goyette, T. M., Waldman, J. . High resolution imaging using 325 GHz and 1.5 THz transceivers. , 373-380 (2004).
  56. Vasconcellos, E. C. C., Zerbetto, S. C., Holecek, J. C., Evenson, K. M. Short-wavelength far-infrared laser cavity yielding new lines in methanol. Opt. Lett. 20 (12), 1392-1393 (1995).

Play Video

Bu Makaleden Alıntı Yapın
Jackson, M., Zink, L. R. Characterizing Far-infrared Laser Emissions and the Measurement of Their Frequencies. J. Vis. Exp. (106), e53399, doi:10.3791/53399 (2015).

View Video