Source: Pollari, E. et al., In Vivo Electrophysiological Measurement of Compound Muscle Action Potential from the Forelimbs in Mouse Models of Motor Neuron Degeneration. J. Vis. Exp. (2018).
This video demonstrates an in vivo technique for measuring compound muscle action potential (CMAP) in mice. It outlines the steps for setting up electrodes, stimulating forelimb neurons that innervate muscle fibers, and recording muscle responses. The technique assesses neuronal demyelination and functional neuron loss.
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Animal Preparation and Anesthesia
2. Measurement of CMAP in Forelimbs
3. Data Acquisition
Figure 1. Positioning of the electrodes for CMAP measurements. The position of the electrodes is presented for hind- (A) and forelimbs (B). The electrodes are numbered as follows: 1: anode and 2: cathode stimulating electrodes, 3: active recording electrode, 4: reference electrode, and 5: grounding electrode.
Figure 2. Representative image of CMAP response. A descriptive CMAP response indicating the points used for calculating the amplitude and latency (A). Latency is determined by the delay from the stimulation to the onset of the CMAP response. Peak-to-peak amplitude is measured from the maximum negative to the maximum positive peak of the biphasic wave. Representative recordings of a healthy non-transgenic animal (B) and a diseased animal with prolonged latency and reduced amplitude (C).
The authors have nothing to disclose.
Resuable subdermal needle electrode, Pl/Ir | Technomed | TE/S61-434 | The Needle is 13 mm (0.51") in length, 0.4 mm (27G) in diameter |
Natus electrodiagnostic system | Natus Neurology | UltraPro S100 | EMG device |
Synergy | Natus Neurology | version 20.1.0.100 | EMG software for UltraPro S100 |
Physitem Controller | Rothacher-Medical GmbH | TCAT-2LV | Heating pad |
combi-vet Base Anesthesia System Digital Flowmeter with TEC 3 Vaporize | Rothacher & Partner | CV 30-301-D | Isoflurane Vaporizer and flowmeter |
Iso-Vet 1000 mg/g | Piramal Healthcare UK Limited | AP/DRUGS/220/96 | Isoflurane |
SOD1-G93A mice | The Jackson Laboratory | #002726 | ALS tg and non-tg control littermates, only females |
PrP-hFUS-WT3 mice | The Jackson Laboratory | #017916 | ALS tg and non-tg control littermates, all groups balanced for males and females |
C57BL/6Jax mice | The Jackson Laboratory | #000664 | Non-tg mice for axotomy, male and female |
C61-PMP22 mice | Mouse line was generously donated by Prof. M. Sereda (The Max Planck Institute of Experimental Medicine, Göttingen, Germany). | CMT tg and non-tg control littermates, all groups balanced for males and female |