This article describes a method for sterilizing worm picks, spatulas, and scalpels using a micro-incinerator in place of an open flame.
Caenorhabtidis elegans (C. elegans) is an optimal model organism for research and education at primarily undergraduate institutions. Undergraduates can quickly learn the sterile technique required to maintain C. elegans cultures. Sterilization of platinum picks used to transfer worms from one plate to another is traditionally done by holding the pick in a flame from a Bunsen burner or ethanol lantern. However, Bunsen burners require a gas source, and both pieces of equipment pose the risk of accidental fire associated with an open flame. Demonstrated here is a technique for sterilizing worm picks, spatulas, and scalpels using an infrared bacteriological loop micro-incinerator. This equipment requires only an electrical outlet and minimizes potential fire hazards. By lowering risk and gas requirements, this technique is well suited for research and teaching in an undergraduate setting.
The model organism C. elegans is well-suited for both research and education at primarily undergraduate institutions (PUIs) due to the low cost, ease of maintenance, and range of applications1,2,3,4. In order to handle worms – for example, to move a worm from one plate to another, experimenters can use a worm pick. A variety of picks can be made or purchased for use with C. elegans. Picks are most commonly made using a platinum or platinum/iridium tip, mounted in a glass, metal, or wooden handle. Glass handles can be made in-house by melting a Pasteur pipette around a platinum wire until the wire is secure. Additional information on C. elegans husbandry, including how to grow and maintain worms and their food sources, can be found in WormBook5 and other sources6,7,8.
When working with C. elegans, aseptic techniques are typically used to prevent contamination with microbes and fungi. Examples of aseptic techniques include sterilization of instruments, autoclaving of reagents, and conducting work in sterile fields. Worm picks are typically sterilized using an open flame9. Additionally, sterilization of the worm pick incinerates worms, thus preventing accidental mix-ups of strains when working with multiple worm strains. Typical methods for sterilizing worm picks involve an open flame from either a Bunsen burner, ethanol lantern, or standard lighter (Table 1). We were motivated to seek safer alternatives to existing methods in the laboratory when an undergraduate student unknowingly spilled ethanol while filling an ethanol lantern and accidentally started a small fire when igniting the lantern. Unfortunately, many accidents have been reported using ethanol lanterns10,11,12. Fortunately, alternative sterilization methods have been validated for use in microbiology, and the purpose of this article is to demonstrate how to use this equipment to sterilize instruments for use with C. elegans.
In microbiology laboratories, the aseptic technique is also critical. Serological loops and wires made of platinum are sterilized either using an open flame13 or a micro-incinerator14,15,16. Other names for micro-incinerators include micro-sterilizers or bacto-incinerators. Advantages of the micro-incinerator over traditional flame methods include reduced fire hazard, elimination of spattering of incinerated materials, and ability to work in a laminar flow hood/biosafety cabinet16,17,18. In fact, both the American Society of Microbiology and the World Health Organization recommends using micro-incinerators over the use of an open flame17,19,20. In comparison with Bunsen burners, micro-incinerators also do not require a gas line, which some laboratories might not have, or might not have located at each bench for students to use. Inspired by these advantages, a protocol was developed to replace the use of flame with micro-incinerators for sterilization of commonly used instruments such as picks, spatulas, and scalpels in the C. elegans laboratory. This method may be appropriate for instructors and researchers seeking to enhance safety and/or flexibility when working with C. elegans.
1. Prepare the micro-incinerator
2. Sterilize the pick, spatula, or scalpel
3. Comparative method – sterilization of instruments using a Bunsen burner
4. Experiment
A simple experiment (section 4) was devised to demonstrate the relative contamination rates using a micro-incinerator versus a flame (Figure 1, Table 2). While these results represent contamination rates across methods, it would not be necessary to repeat this method to use the micro-incinerator technique. The experiment was run in triplicate. Negative control was sterile water with no bacteria. The positive control used neither sterilization technique: the pick was dipped in the diluted OP50 culture then transferred directly to the sterile water. All replicates and conditions were run in parallel on the same day. In all three negative control plates, zero colonies were counted. A mean count of 4.7 (± 0.3 SEM) colonies was obtained when the Bunsen burner was used to sterilize picks. A mean count of 3.3 (±1.2 SEM) colonies was observed in the micro-incinerator condition. However, a mean count of 298.3 (±17.9 SEM) colonies was obtained in the positive control condition. A 2-tailed t-test assuming equal variance comparing the Bunsen burner to micro-incinerator yielded no statistically significant difference, p = 0.35. Thus, the micro-incinerator achieved sterility results equally effective to the Bunsen burner.
Figure 1: Bacterial counts across sterilization methods. Picks were dipped in 1:100 OP50 culture in sterile water and then sterilized using a Bunsen burner or micro-incinerator. Picks were then dipped in sterile water, plated on LB agar22,23, and incubated for 24 h at room temperature, and colonies were counted manually. Positive control had no sterilization, and negative control used sterile water with no bacteria. n = 3 replicates per condition. Note: y-axis is broken to allow separation of data points in relevant portions of the graph. Please click here to view a larger version of this figure.
Sterilization Method | Cost | Lab Requirements | Advantages | Disadvantages | |||
Micro-incinerator | $365–530 | 120 V or 230 V outlet | • Portable • No open flame or exposed heating element • Useable in laminar flow hoods and biological safety cabinets |
• Warm up time • Higher cost |
|||
Bunsen Burner | $24–169 | Gas Line | • Fast set up • Low cost |
• Open Flame • Not recommended for use in laminar flow hood or biological safety cabinet |
|||
Ethanol Lamp | $11 | None | • Fast set up • Low cost • Refillable |
• Open Flame • Safety hazard when refilling • Not recommended for use in laminar flow hood or biological safety cabinet • Not allowed at certain institutions |
|||
Lighter | $5–8 | None | • Low cost • Accessible • Disposable • Refillable |
• Open Flame • Hand operated • Not recommended for use in laminar flow hood or biological safety cabinet |
Table 1: Comparison of methods for sterilizing instruments. Four methods for sterilizing instruments were compared based on advantages, disadvantages, costs, and laboratory requirements.
Replicate | Condition | |||
Micro-incinerator | Bunsen Burner | Negative Control | Positve Control | |
1 | 1 | 5 | 0 | 278 |
2 | 4 | 4 | 0 | 334 |
3 | 5 | 5 | 0 | 283 |
Mean | 3.3 | 4.7 | 0.0 | 298.3 |
SEM | 1.2 | 0.3 | 0.0 | 17.9 |
Table 2: Raw data of bacterial counts across sterilization methods. Picks were dipped in 1:100 OP50 culture in sterile water and then sterilized using a Bunsen burner or micro-incinerator. Picks were then dipped in sterile water, plated on LB agar22,23, and incubated for 24 h at room temperature, and colonies were counted manually. Positive control had no sterilization, and negative control used sterile water with no bacteria. n = 3 replicates per condition. Mean and SEM reported below individual counts.
C. elegans is a model organism well suited for exercises in undergraduate teaching laboratories. The use of micro-incinerators in place of open flames provides benefits in both research laboratories and classroom laboratories. In fact, undergraduate laboratory courses may pose a higher risk of accidental fires given the number of newly trained scientists in the room. In addition, the risk of fire increases when ethanol is used to sterilize instruments near the source of flame as ethanol vapors are ignitable. The portability also confers an advantage for classrooms where gas lines are not installed at each bench. This method has been employed in teaching and research laboratories at our institution, resulting in no increases in contamination and zero laboratory safety accidents since its incorporation in 2016.
To ensure compatibility with micro-incinerators, a range of picks with different mountings, wire compositions, and wire gauges were tested. Wire composition included 100% platinum as well as 90% platinum/10% iridium with a wire thickness of 30-32 G, and regardless of thickness and composition, the heating method did not compromise wire integrity. Mountings included two different types of commercially available pick handles and in-house-made glass mountings from Pasteur pipettes. Note that picks do not glow red-hot as they do in the flame. However, sufficient sterilization is still achieved as long as the sterilizer has reached the proper temperature. Thus, it is critical to allow the micro-incinerator to warm up for 10 or 20 min, as indicated in the manufacturer’s instructions. Keeping the instrument in the chamber for at least 5 s to achieve sterilization is also critical. Leaving the instrument in the chamber longer than 7 s will not cause harm to the instrument but is unnecessary. While this is a relatively straightforward procedure with minimal steps and is unlikely to need troubleshooting, it may take some practice to learn to steady the instrument in the barrel without touching the sides.
In order to replace an open flame, a sterilization method must cover all of the applications used in a laboratory. In addition to sterilizing instruments, C. elegans laboratories may also use Bunsen burners to create a sterile field to do other tasks such as pouring plates or inoculating cultures13. However, whether this creates a sterile field or draws in still-viable contaminants remains controversial14. Although not an option at all institutions, a biosafety cabinet or laminar flow hood can be used for these purposes, allowing a laboratory to function without the use of open flames. Instruction manuals for most micro-incinerators recommend against use for sterilization of scalpel blades because scraping of the inner walls damages the sterilizer. However, if carefully using a guide, one can sterilize a scalpel blade or spatula without touching the inner walls. This extends the use of the technique to allow for chunking without using a flame and allows a C. elegans laboratory to function without switching techniques between sterilizing different objects.
As outlined in Table 1, micro-incinerators offer increased safety, increased compatibility with laminar flow hoods, and increased portability over flame-based methods but have limitations. They are more costly than the other methods and require a warm-up time before sterilization temperatures are achieved. In conclusion, this method which is routinely used in many microbiology laboratories, may be applicable in some C. elegans research and teaching laboratories seeking to improve laboratory safety without compromising sterility.
The authors have nothing to disclose.
The authors would like to acknowledge Suzanne Howard and Justin Finne. This work was funded by the Wellesley College Neuroscience Department. N2 worms were provided by the CGC which is funded by the NIH Office of Research Infrastructure Programs (P40 OD010440). The publication fees for this article were supported by the Wellesley College Library and Technology Services Open Access Fund.
90% platinum 10% iridium wire | Tritech | PT-9010 | Other sources and wire compositions may be used. |
Agarose | Sigma Aldrich | A6013 | LB agar ingredient |
Bunsen burner | Fisher Scientific | 50-110-1225 | Other Bunsen burners may be used |
Ethanol Lamp | Carolina | 706604 | Included here as a reference to Table 1 |
Lighter | Carolina | 706636 | Included here as a reference to Table 1 |
Loop holder accessory | Fisher | 22-630-002 | Referred to in the manuscript as "guide" |
Micro-incinerator | Thomas Scientific | 1154J15 | There are many companies that sell similar equipment. Similar models also sold by Benchmark Scientific (B1001), Fisher Scientific (22-630-001), Carolina (703400), and BT Lab Systems (BT1702). |
N2 worms | CGC | N2 | |
NaCl | Sigma Aldrich | S5886 | LB ingredient |
OP50 E. coli | CGC | OP50 | |
Petri dish | Fisher | 08-772B | |
Pick handle | Tritech | TWPH1 | |
Scalpel blade | Fisher | 12-000-161 | |
Scalpel handle | Fisher | 12-000-164 | |
Spatula | Fisher | 14-374 | Other spatulas will work |
Sterile cell spreaders | VWR | 76206-438 | Other cell spreaders may be used as long as they are sterile |
Tryptone | Sigma Aldrich | T7293 | LB ingredient |
Yeast Extract | Sigma Aldrich | Y1625 | LB ingredient |