Here, we present the fabrication protocol of an organic charge-modulated field-effect transistor (OCMFET)-based device for in vitro cellular interfacing. The device, called a micro OCMFET array, is a flexible, low-cost, and reference-less device, which will enable the monitoring of the electrical and metabolic activities of electroactive cell cultures.
Modern electrophysiology has been constantly fueled by the parallel development of increasingly sophisticated tools and materials. In turn, discoveries in this field have driven technological progress in a back-and-forth process that ultimately determined the impressive achievements of the past 50 years. However, the most employed devices used for cellular interfacing (namely, the microelectrode arrays and microelectronic devices based on transistors) still present several limitations such as high cost, the rigidity of the materials, and the presence of an external reference electrode. To partially overcome these issues, there have been developments in a new scientific field called organic bioelectronics, resulting in advantages such as lower cost, more convenient materials, and innovative fabrication techniques.
Several interesting new organic devices have been proposed during the past decade to conveniently interface with cell cultures. This paper presents the protocol for the fabrication of devices for cellular interfacing based on the organic charge-modulated field-effect transistor (OCMFET). These devices, called micro OCMFET arrays (MOAs), combine the advantages of organic electronics and the peculiar features of the OCMFET to prepare transparent, flexible, and reference-less tools with which it is possible to monitor both the electrical and the metabolic activities of cardiomyocytes and neurons in vitro, thus allowing a multiparametric evaluation of electrogenic cell models.
In vivo monitoring of electroactive cells, such as neurons and cardiomyocytes, represents a valid and powerful approach in fundamental research applications for the human brain, functional connectivity studies, pharmacology, and toxicology. The tools usually employed for such studies are mainly based on microelectrode arrays (MEAs)1,2,3,4,5 and increasingly more efficient and powerful field-effect devices (FEDs)6,7,8,9,10,11,12. These two families of devices allow the real-time monitoring and stimulation of the electrical activity of neurons and cardiomyocytes and are usually characterized by robustness, ease of use, and reliability. These features make MEAs and FEDs the gold standard for electrophysiological applications, being currently employed to interface with standard cellular cultures, organotypic brain slices, and tridimensional organoids13,14,15,16. Despite their widespread use and their impressive features, MEAs and FEDs present some limitations such as high cost, the rigidity of the materials, and the presence of a usually bulky reference electrode, which has to be placed in the measurement liquid environment and is necessary for proper operation of the devices.
To explore alternative solutions for cellular interfacing, much effort has been invested in the past decade into the study of electronic devices based on organic materials and innovative fabrication techniques17. Among the several organic devices studied to address the aforementioned limitations, a peculiar organic transistor called OCMFET has been recently proposed as a valid alternative to MEAs and FEDs18. In addition to the standard features offered by the organic electronics technology, such as low-cost materials and fabrication techniques, optimal mechanical and chemical properties, optical transparency, and biocompatibility, the OCMFET also offers an ultra-high charge sensitivity (due to its double-gated structure) without the need of an external reference electrode. Moreover, this organic sensor has the remarkable capability of sensing different analyte/physical parameters, depending on the specific functionalization of its sensing area, which is separated from the transistor area19,20. All these features can be conveniently exploited for the acquisition of different parameters within a cellular culture. In particular, in addition to being able to detect the neuronal/cardiac electrical activity, it is also possible to exploit the ultra-high pH sensitivity offered by the peculiar double-gated structure of the OCMFET by using a simple physical functionalization21 to reliably monitor the slight local pH variations caused by cellular metabolic activity.
In in vitro cell biosensing, the monitoring of cellular metabolic activity is a powerful indicator of the state of the culture and can be used to assess the cellular response to various stimuli, such as drug administration and electrical stimulation22,23. Moreover, in the specific case of neural applications, monitoring both the electrical and the metabolic activities is of great interest, particularly in pharmacology and toxicology24. With the intent of conveniently addressing the requirements of modern in vitro electrophysiology while at the same time offering all the advantages of the OCMFET, a device called Micro OCMFET Array (MOA) has been recently introduced. The MOA is an OCMFET-based array with specialized sensing areas specifically designed for in vitro cellular interfacing, enabling the multiparametric analysis of electrogenic cells cultures. In particular, two MOA channels have bigger sensing areas to maximize their sensitivity and can be selectively functionalized to monitor specific parameters of interest, such as the pH variations of the culture medium. The other OCMFETs in the structure act as extracellular electrical activity sensors. Figure 1 shows the structure of a 16 channel MOA. This capability, combined with the absence of an external reference electrode, makes the MOA a very interesting tool for in vitro applications. This work presents the step-by-step fabrication protocol of a multisensing MOA for the in vitro detection of the electrical and metabolic activities of neurons and cardiomyocytes. Figure 2 shows the main fabrication steps, the materials used, and the device structure.
All applicable international, national, and/or institutional guidelines for the care and use of animals were followed. All efforts were made to reduce the number of animals for the project and to minimize their suffering.
1. Preparation of the developing solution, the etching solutions, the organic semiconductor solution, and the photolithographic masks
2. Substrate selection and preparation
3. FG: titanium deposition
4. FG patterning
5. Gate dielectric deposition
6. Opening of the sensing areas of the OCMFET for electrical activity recording and formation of the vias to access the back of the FGs
7. Self-alignment of source and drain with the FG
8. Gold deposition, channel formation, and patterning of the sources, drains, and control gates
9. Deposition and activation of the Parylene C for pH sensing
10. Semiconductor deposition, culturing chamber placing, and final cut-out of the device from the PET
11. Electrical characterization of transistors
The potential of the MOA has been validated here for both electrical activity recordings and metabolic activity monitoring. The precise estimation of the capabilities of the device to detect extracellular action potentials was based on a thorough characterization with rat cardiomyocytes cultures (particularly in primary rat cardiomyocytes measured at 8 days in vitro [DIV])18. Figure 3A shows a complete MOA with 16 OCMFETs. The top inset shows an example of a confluent rat cardiomyocyte culture adhering to the surface of the MOA. To highlight their health, the cells have been immunostained for the sarcomeric protein, tropomyosin, after the recording session. The bottom inset shows a single cardiomyocyte signal measured with an OCMFET.
Interestingly, the device could detect spontaneous electrical activity and the activity induced upon the administration of different chemicals, as shown in Figure 3B. This validation was crucial to demonstrate the feasibility of using this approach for electrogenic cell interfacing. Because of the array configuration, the MOA also allowed for the reconstruction of the propagation velocity of the cardiac signal, thus demonstrating the suitability of the system for the study of cellular networks (Figure 3C). For further validation to determine the actual detection limit of the device, the MOA was also tested with striatal neurons (21 DIV)18, with interesting results in terms of signal amplitude and the reliability of the recordings. As seen in Figure 3D, the OCMFET could amplify neuronal field potentials with remarkable stability, showing signal-to-noise ratios (SNRS) of up to 3.2 (in the same range as that of SNRs obtained with standard MEAs25). The recording setup consisted of custom multichannel electronics for the transistor biasing and the signal readout and conditioning. Each channel for the electrical recording has a first stage consisting of an I/V converter with a 1 MΩ feedback resistor and a 150 Hz-1.3 kHz bandpass filter with a voltage gain of 110. For all the presented measurements, the transistors were biased with VDS = VGS = -1 V. The A/D conversion and the data visualization and storing were performed using a data acquisition board (see the Table of Materials). All the measurement sessions were conducted inside a Faraday cage to minimize the electrical, environmental noise on the system.
As previously mentioned, by exploiting the simple physical functionalization presented in the protocol, it was possible to prepare highly sensitive pH sensors with a supernernstian response. Because of the presented fabrication approach, these pH devices could be integrated into an MOA and used to monitor the slight pH variations induced by the metabolic activity of primary hippocampal rat neurons26. In particular, as shown in Figure 4, only one of the two OCMFETs dedicated to low-frequency sensing was selectively functionalized to demonstrate the feasibility of the approach. This selective functionalization allowed the evaluation of the response of the two OCMFETs to chemically induced metabolic variations: in particular, a high metabolic state can be obtained using bicuculline (BIC), an inhibitor of GABA A receptors27, while a low metabolic state can be induced by the addition of tetrodotoxin (TTX), which eventually causes cellular death28. The recording setup consisted of the same custom multichannel electronics used for the electronic activity measurements.
Unlike the previous case, two dedicated channels were used to record the slow variations induced by the cellular metabolic activity. Each channel consisted of a simple circuit composed of two main blocks: an I/V converter with a 1 MΩ feedback resistor and a low-pass filter with a cut-off frequency of 10 Hz. The transistors were biased with VDS = VGS = -1 V, and all the measurements were carried out inside a Faraday cage to minimize the impact of external noise on the recordings (this is a particularly important aspect considering the low current fluctuations induced by the cellular metabolic activity). During the experiments, the cultures were maintained in a low-buffered culture medium, and the whole system was placed in a controlled environment (37 °C and a continuous CO2/air flux). As expected, only the current of the pH-sensitive OCMFET could be modulated by the addition of 25 µM BIC. This was further confirmed by the induction of the current variation by the corresponding variation of the cellular metabolic activity.
The same experiment was repeated after the addition of 10 µM TTX, which resulted in a gradual slowing down of the cellular metabolism. Following the addition of the TTX, neither the pH-sensitive OCMFET nor the pH-insensitive one showed any response, thus demonstrating the efficacy of the approach. These results demonstrate the effectiveness of the proposed functionalization and its relative stability for up to 2 weeks. An important conclusion that can be drawn from the proposed experiments (both the electrical activity and the metabolic activity) is that it is possible to prepare different kinds of sensors by selectively functionalizing different OCMFETs within the same culturing area. This aspect represents a non-trivial achievement in biosensing for cellular applications because being able to monitor different parameters within the same cell culture is crucial for better characterization of the complexity of those biological systems.
Figure 1: Top view of a 16 channel MOA for metabolic and electrical monitoring of electroactive cells. Scale bar = 1 cm. Abbreviations: OCMFETs = organic charge-modulated field-effect transistors; FG = floating gate; S/D = source/drain; MOA = micro OCMFET array. Please click here to view a larger version of this figure.
Figure 2: Main fabrication steps of an MOA for metabolic and electrical monitoring of electroactive cells. (A and B) The evaporated Ti film is patterned using a standard photolithographic process to prepare the floating gate of the OCMFETs. (C) Deposition of 15 nm of Parylene C. This layer, together with the native Ti oxide, acts as the gate dielectric of the transistors. (D and E) The Parylene C layer is patterned using plasma oxygen treatment. A patterned photoresist layer is used to selectively expose the sensing areas for the electrical recordings and the floating gate back contacts. (F) Patterning of the Au top contacts, namely the source, drain, control gate, and floating gate back contact. A self-alignment technique is used to improve the electrical performance of the device. (G–I) Deposition of the second layer of Parylene C on the sensing area of the OCMFETs for metabolic activity monitoring. After the oxygen plasma exposure, this layer will act as the pH-sensitive membrane (J). (K) Cross-section of a complete MOA (with materials) after the deposition of the organic semiconductor (TIPS Pentacene) and the culture chamber positioning. Abbreviations: OCMFETs = organic charge-modulated field-effect transistors; FG = floating gate; S/D = source/drain; MOA = micro OCMFET array; CG = control gate; PET = polyethylene terephthalate; Par C = Parylene C; TIPS = 6,13-bis(triisopropylsilylethynyl) pentacene; ABS = acrylonitrile butadiene styrene. Please click here to view a larger version of this figure.
Figure 3: Cellular electrical activity recordings with an MOA. (A) A confluent culture of rat cardiomyocytes (8 DIV) adhering to the surface of an MOA, fixed after a recording session and immunostained for the sarcomeric protein, tropomyosin (upper inset). Bottom inset: example of a single cardiomyocyte signal measured with an OCMFET. Scale bar = 150 µm. (B) Chemical tuning of the electrical activity of a cardiomyocyte culture. The activity acceleration resulted from the addition of 100 mM norepinephrine, while suppression resulted from the addition of 100 mM verapamil. Left: beating frequency modulation; right: statistics on 5 OCMFETs-average and standard deviation: spike-count on 4 min of basal (129 ± 4.6), norepinephrine-mediated (280 ± 28.6) and verapamil-mediated activity (15 ± 1.9). (C) Reconstruction of the propagation of a cardiac signal. Right: raster plot of the spontaneous activity of the culture indicating the propagation of the signal from site 14 to site 41 (right). (D) Action potentials of striatal cells from rat embryo (21 DIV). This figure has been modified from 18. Abbreviations: OCMFET = organic charge-modulated field-effect transistor; MOA = micro OCMFET array; NE = norepinephrine; VER = verapamil; DIV = days in vitro. Please click here to view a larger version of this figure.
Figure 4: Metabolic activity recordings with an MOA. Response of the (A) pH-sensitive and (B) pH-insensitive channels of an MOA to the addition of 25 µM BIC before and after the addition of 10 µM of TTX. After the TTX addition, the behavior of the pH-sensitive channel becomes similar to that of the pH-insensitive one. In particular, no current variation can be observed after the BIC addition due to the TTX-induced cellular death. (C) MOA for metabolic activity recordings. The pH-sensitive and the pH-insensitive OCMFETs are outlined in green and red, respectively. Inset: healthy hippocampal neurons cultured onto the device after 15 DIV. Scale bar = 50 µm. This figure has been modified from 26. Abbreviations: OCMFET = organic charge-modulated field-effect transistor; MOA = micro OCMFET array; BIC = bicuculline; TTX = tetrodotoxin; DIV = days in vitro. Please click here to view a larger version of this figure.
Unlike previous methods for the fabrication of OCMFETs for cellular applications18,29, the proposed method is specifically designed to prepare MOAs that can simultaneously detect electrical and metabolic cellular activity. Moreover, this approach to achieve pH sensitivity has the advantage of being compatible with standard fabrication protocols and does not involve any chemical modification of the sensing area (this aspect ensures the biocompatibility of the whole device). The pH sensitivity is achieved using the same material used as a gate dielectric (i.e., the biocompatible Parylene C), making this approach fast and reproducible.
The final result of this approach is a flexible, transparent, low-cost, and multisensing organic tool for in vitro cellular applications. The fact that this can be obtained using a single transistor structure and a simple physical modification of the sensing area adds to the advantages offered by the use of organic electronic materials and methods. Moreover, because the transduction principle of the OCMFET does not strictly depend on the specific semiconductor or FG material, the whole process can be modified and upscaled depending on the specific application.
A critical aspect of the proposed technique is related to the reproducibility of the plasma activation technique. To obtain consistent results, both the Parylene C thickness and its etching rate must be controlled. Frequent calibration of the Parylene C deposition process and the plasma cleaner are absolutely necessary. Other critical aspects, which also contribute to the reproducibility of the process, are the careful handling of the device and the deposition of the organic semiconductor. A simple drop-casting technique was used here, which intrinsically poses reproducibility limitations. To minimize those issues, as described in protocol step 10.1, the same amount of semiconductor solution should be used every time, and the solvent evaporation should be standardized as much as possible. Keeping a constant temperature using a hot plate and covering the substrate after each droplet deposition will help in slowing down the evaporation process. To further minimize this problem, the deposition technique (e.g., using an inkjet printing method) could be switched30.
A limitation of the proposed protocol stems from the nature of the functionalization of the OCMFET for pH sensing. The stability of the pH sensors is limited to a few weeks26. However, the stability window of the proposed approach is sufficiently large to cover the standard incubation times needed for neuronal culture growth (2-3 weeks). Other types of sensing area functionalization should be considered for longer experiments. The fabrication protocol uses a dedicated back contact, allowing electrical access to the FGs. This contact, which is left floating during the normal operation of the device, can be exploited for the electrical characterization of the device and the functionalization of the sensing areas using different techniques (e.g., electrodeposition).
This procedure represents a convenient way to prepare a multi-sensing device for cellular applications without the need for expansive materials or cleanroom facilities. Despite the performance and stability limitations due to the employment of an organic semiconductor and physical (not chemical) functionalization of the sensing area, similar approaches could be used to prepare low-cost (and potentially disposable), mechanically flexible, and optically transparent sensors and biosensors, which can provide researchers in cellular biology, tissue engineering, and neuroscience with novel specialized tools for studying cellular systems in vitro.
The authors have nothing to disclose.
The authors acknowledge funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No. 882897-Search&Rescue project and the PON project "TEX-STYLE" ARS01_00996, PNR 2015-2020.
3-(Trimethoxysilyl)propyl methacrylate | Sigma Aldrich | 440159 | |
3D printer Makerbot Replicator 2x | Makerbot | https://www.makerbot.gr/. Estimated price: 2k-3k euros. | |
ABS filament | |||
Anisole | Sigma Aldrich | 296295 | |
Bromograph model Hellas | Bungard | https://www.bungard.de/. Estimated price: 1k-2k euros. | |
Gold | Local seller | ||
Hydrofluoric acid | Sigma Aldrich | 695068 | |
Iodine | Sigma Aldrich | 207772 | |
Kapton tape | polyimide insulation tape | ||
Laser cutter VLS2.30 | Universal Laser Systems | https://www.ulsinc.com/it. Estimated price: 20k euros. | |
Multichannel Systems acquisition board | www.multichannelsystems.com | ||
NaOH pellets | Sigma Aldrich | 567530 | |
Parylene C dimer | SCS special coating systems coating | ||
PDMS Silgard 184 | Sigma Aldrich | 761036 | |
PDS 2010 LABCOATER 2 Parylene Deposition System | SCS special coating systems | https://scscoatings.com/. Estimated price: 50k euros | |
PET film biaxially oriented (thickness 0.25 mm) | Goodfellow | ES301450 | |
Petri dishes | |||
Plasma cleaner Gambetti "Tucano" | Gambetti | https://www.gambetti.it/. Estimated price: 20k euros. | |
Positive photoresist AZ1518 | MicroChemicals | ||
Potassium iodide KI | Sigma Aldrich | 221945 | |
Source Meter 2636 | Keithley | https://it.farnell.com/. Estimated price: 18k euros | |
Spin coater unit | Ossila | https://www.ossila.com/. Estimated price: 2.5k euros. | |
Stereoscopic microscope SMZ745T | Nikon | https://www.microscope.healthcare.nikon. com/. Estimated price: 2k-3k euros. |
|
Thermal evaporator unit | |||
TIPS pentacene (6,13-Bis(triisopropylsilylethynyl)-pentacene) | Sigma Aldrich | 716006 | |
Titanium wire | Goodfellow | TI005129 | |
Ultrasonic bath | Falc Instruments | https://www.falcinstruments.it/. Estimated price: 1k euro. |