Here we describe an appropriate electrophysiological technique to diagnose and treat patients with erectile dysfunction.
Erectile dysfunction (ED) is a common disease in males. In the past, the first-line treatment of ED was mainly noninvasive-psychotherapy and oral phosphodiesterase 5 (PDE5) inhibitors. Oral PDE5 inhibitors often need to be used before sexual intercourse and do not repair the pathological damage; hence, the therapeutic effect for secondary ED caused by neurological or endocrine disorders is poor. Second-line treatments mainly include penile corpus cavernosum injection of alprostadil, transurethral administration, vacuum negative pressure devices, and other methods, with obvious side effects such as local pain.
The third-line treatment mainly refers to penile prosthesis implantation. Indications of this treatment are strict, complications such as mechanical failure and infection may occur after operation, and it is expensive. Other treatments such as stem cell therapy and gene therapy are still in the experimental research stage and have not been used in clinics. A new treatment based on an electrophysiological technique combines a medical infrared thermal imager with low-frequency (20-50 Hz) neuromuscular electrical stimulation, which has achieved good results in the prevention and treatment of female pelvic floor dysfunction.
Male generative organs are located in the pelvic floor area, and their normal function not only depends on the integrity of the structure and function of the male generative organs, but is also closely related to the blood vessels, nerves, muscles, and other pelvic floor organs. Therefore, this electrophysiological technique was applied to male ED, focusing on the observation of the penis, groin, and hypogastrium for accurate diagnosis and treatment. This demonstrated effective improvement in the conscious erectile status and erectile function scores of patients suffering from ED.
Erectile dysfunction (ED) refers to the male inability to achieve and/or maintain a satisfactory erection during sexual behavior1. The common etiologies of ED are psychological, neurotic, anatomical, vascular, and drug-induced. Worldwide, the prevalence of ED in men is high and increases with age2. ED can affect a patient’s self-confidence, quality of life, and the stability of family relations. In addition, research shows that ED increases the risk of cardiovascular disease in patients in the future3. Therefore, once ED is diagnosed, it should be treated as soon as possible. At present, the main therapies for ED are oral PDE5 inhibitors and surgeries. Studies show that PDE5 inhibitors are ineffective in up to 35% of patients suffering from ED4, resulting in a discontinuation rate between 35% and 45%5. The reasons for the discontinuation of PDE5 inhibitors include concerns about possible side effects and high drug costs6. Additionally, surgical treatment could cause complications such as infection and pain. However, electrophysiological technology can be used to analyze the temperature of patients in different positions under different movements by using medical infrared thermal imaging visual thermography to identify the abnormal parts of the human body, and then patients can be treated with low-frequency (20-50 Hz) neuromuscular electrical stimulation.
The low-frequency nerve and muscle electrical stimulator is a continuous activation instrument with simple and effective operation and a wide range of indications, which has been widely used in obstetrics and gynecology7, cardiovascular diseases8, and perioperative rapid rehabilitation9. In particular, it has achieved good results in the prevention and treatment of female pelvic floor dysfunction diseases and female pelvic floor discipline construction10. It is noteworthy that this electrophysiological technology has not yet been applied in andrology. The medical infrared thermal imager can produce infrared wave images emitted by humans. As a part of the temperature regulation process, the intensity can be changed according to the health status of the patients11, and the physiological and pathological reactions of diseases can be studied from the cell metabolism and human functional changes to provide a specific auxiliary diagnostic method for clinical research. There are temperature differences between individuals due to the differences in human anatomy, tissue metabolism, blood circulation, nerve function, and blood states.
Moreover, different images can be formed by medical infrared thermal image scanning. Comparisons of the similarities and differences between the images of the normal state of the body and abnormal states can help diagnose the nature and degree of the disease in combination with clinical diagnosis. These comparisons can also help accomplish accurate diagnoses of related diseases under the infrared visible state by combining these data with the low-frequency (20-50 Hz) neuromuscular therapy instrument. Accurate electrophysiological diagnosis and treatment parameters, including treatment sites, blood vessels, muscles, and nerves, are determined using computer software supporting the low-frequency neuromuscular therapy instrument, and individualized treatment plans are formulated to achieve immediate and precise treatment. Moreover, related parameters can be seen simultaneously, and it is convenient for the observation and evaluation of the curative effect.
Male pelvic floor muscles can promote erection and ejaculation12. By monitoring intracavernous pressure, spontaneous contraction and electrical stimulation increase muscle strength in the sciatic cavernous body13. Although patients suffering from ED have potential pelvic floor muscle dysfunction, the treatment of ED is still based on drug treatment and lifestyle improvement. In this study, electrophysiological technology, including medical infrared thermal imaging and low-frequency neuromuscular electrical stimulation, provides a new method for the treatment of ED patients through the diagnosis and treatment of nerves, muscles, and blood vessels in abnormal parts of patients suffering from ED.
During sex, penile erection is largely dependent upon sufficient blood flow into the corpus cavernosum, which requires the coordination of arterial endothelium-dependent vasodilation and sinus endothelium-dependent cavernous smooth muscle relaxation14. Nitric oxide (NO) is the primary neurotransmitter of the peripheral erectile-promoting nerves, released by parasympathetic autonomic nerves and sinus endothelium to produce cyclic guanosine monophosphate (cGMP). This cGMP relaxes the cavernous smooth muscle, resulting in increased pressure in the cavernous body to achieve erection15. By monitoring the formation of NO and cGMP, it was confirmed that electrical stimulation could lead to the formation of NO and cGMP in the penile cavernous smooth muscle16.
From the perspective of anatomical structure, male reproductive organs are located in the pelvic floor-related areas, and their normal function depends not only on their structural and functional integrity but also on the blood vessels, nerves, muscles, and other organs associated with the pelvic floor. Studies have shown that contraction of the superficial pelvic floor musculature can increase intracavernous pressure by restricting venous return to the base of the penis to produce an erection17. In addition, neural, endocrine, immune regulatory networks, and psychophysiological factors also play important roles. Problems in any one or more of the above areas will promote the occurrence and development of male diseases. Previous studies have shown that male pelvic floor muscle training, including electrical stimulation, can improve stress urinary incontinence, overactive bladder, ED, premature ejaculation, lower urinary tract syndrome, and muscle-related pelvic pain12. Further, physical exercise therapy and electrical stimulation can effectively treat premature ejaculation with an effective rate of 64%18.
Although functional electrical stimulation therapy is widely used in sexual dysfunction19, there are few studies on the treatment of ED. There are many advantages of the described electrophysiological technique; it is suitable for a variety of diseases caused by nerve and muscle damage, including pelvic floor dysfunction diseases, motor system injury diseases, nervous system diseases, digestive system diseases, and endocrine diseases. Additionally, it has no side effects, is easy for patients to accept, and has been used in clinical practice for many years because of its stable, safe, and reliable features.
This study draws lessons from this electrophysiological technique that has achieved good results in the prevention and treatment of female pelvic floor dysfunction. Medical thermal imaging is used to detect, before low-frequency neuromuscular electrical stimulation is used to accurately treat, abnormal sites through blood vessels, muscles, and nerves.
We use a medical thermal imager to find the abnormal parts and then treat them with low-frequency neuromuscular current stimulated by blood vessels, muscles, and nerves, which provides a new method for the diagnosis and treatment of patients suffering from ED. However, due to the short duration of this study and the small number of samples, we will continue to increase the number of cases to observe the recovery of patients suffering from ED treated with this electrophysiological technique. In addition, compared with the current ED treatment methods, this method has the disadvantages of a slow effect and long therapeutic time.
The authors have nothing to disclose.
This research was supported by a grant from the National Health Commission Science and Technology Plan Project, funded by the Medical and Health Science and Technology Development Research Center of the National Health Commission (grant number: HDSL202001051).
Low-frequency nerve and muscle electrical stimulator | Foshan Shanshan Datang Medical Technology Company | 20182260716 | |
RigiScan Plus Monitor | GOTOP Medical | 20162211942 |
.