This method involves utilization of clinical diagnostic data for prostate cancer patients in order to guide sampling procedures, when biobanking tissue following radical prostatectomy. This overcomes issues with previously published methods around efficiency and availability of fresh tissue for a wider range of downstream applications.
Previous methods for biobanking prostate tissue, following radical prostatectomy, generally involved random sampling. In order to increase efficiency, and enable a greater range of downstream applications, a more targeted method of sampling prostate tissue was developed. Here we use both magnetic resonance imaging (MRI) and biopsy data to target specific areas of the organ for sampling. The method involves use of a previously published prostate slicing device which removes a 5 mm transverse slice from a predetermined region of the prostate, followed by the removal of 6 mm punch biopsies from predetermined areas of this slice. These samples can be stored frozen or fixed for biobanking purposes, or used fresh immediately with 70% confidence of tumor content, as compared with 10% confidence from the random sampling approach. This enables the use of all standard downstream techniques such as genomics, proteomics or histological work, but also work that requires fresh tissue such as live tissue imaging or ex vivo culture.
Access to high quality human prostate cancer tissue is a key requirement for driving effective research in the field. There are a number of existing methods to sample prostate tissue following radical prostatectomy for research. Typically these involve using punch biopsies to take random samples from a fresh, frozen or fixed slice of prostate tissue, and retrospectively confirming whether or not tumor is present in each sample by hematoxylin & eosin (H&E) as assessed by a uropathologist1,2,3,4,5. A recent review has compiled an overview of these existing methods6. These methods are useful for certain downstream applications, where tissue can be stored and assessed for tumor content at a later date, such as large scale genomic analyses like the International Cancer Genome Consortium (ICGC) and The Cancer Genome Atlas (TCGA)4,7. However, these methods could be improved upon in if we were to use magnetic resonance imaging (MRI) and/or biopsy data to target specific areas of the prostate for sampling. This would improve the methodology in two ways; firstly, by reducing the number of tissue samples collected, increasing efficiency and reducing pressure on pathology departments and cost of storage, and secondly, by allowing fresh tissue to be used immediately without the need for immediate confirmation of tumor content, for new state of the art downstream technologies such as live tissue imaging, organoid generation or ex vivo culture. This research need has led to the development of the PEOPLE (PatiEnt prOstate samPLes for rEsearch) method, and the results from the first 84 cases biobanked using PEOPLE were recently published8. A variation of this method has also been published with a three-dimensional (3D) printed slicing apparatus and patient-specific mold, in order to facilitate ex vivo MRI on pre- and post-fixation tissue9,10.
The protocol adheres to local guidelines and is approved by the UCL/UCLC Biobank Research Ethics Committee (Reference 15/YH/0311).
NOTE: As this method involves the sampling of human tissue, all local procedures regarding ethics and consent must be observed in advance of beginning the protocol. Radical prostatectomy cases may be included if both MRI and biopsy data are available in advance of surgery, with tumor diameter ≥5 mm. Cases should be excluded if the index lesion is not well defined, i.e., only diffuse changes are visible by MRI.
1. Prostate Slicing Apparatus
2. Tumor Targeting
3. Collection of pProstate
4. Specimen Preparation
5. Prostate Slicing
6. Tissue Sampling
7. Submission of Prostate for Local Diagnostics
8. Decontamination of Apparatus
Fresh prostate tissue sampled using the PEOPLE method can be used for a variety of downstream techniques, including genomic sequencing and ex vivo culture. The first 59 cases sampled using this method have been previously published in comparison with an earlier version of the method, along with initial downstream data8. The time from first slicing the prostate to freezing/fixing the punch biopsies here was approximately 1 min, which was kept to a minimum to avoid degradation of RNA. Time from removal of the prostate to prostate slicing should also be kept to a minimum, though here this took approximately 20 min due to our theatre and pathology labs being in different locations.
Depending on the downstream application, typically at least two samples are taken: one from an area of anticipated tumor tissue and one from an area of anticipated benign tissue. The key measure of success for the sampling method itself is to assess the tumor content in a given sample.
For entry into the 100,000 genomes project, an H&E stained tissue section must be assessed by a uropathologist, and the sample must contain at least 40% tumor cells. Samples that contain less than 40% tumor may still be included in the project if they are successfully macrodissected. Of the first 92 cases sampled in this manner, 64% contained at least 40% tumor and were submitted to the 100,000 Genomes Project without macrodissection. DNA was extracted and was of sufficient yield and quality in all cases (Table 1). An initial subset of 59 of these samples was previously published in comparison with an earlier method8.
For ex vivo culture, matched tumor and benign tissue must be of sufficient quality to withstand 72 h culture without significant degradation. Multiple tissue samples from a total of three patients were cultured successfully8.
Figure 1: Prostate slicing apparatus. This apparatus was obtained under material transfer agreement from the Institute of Cancer Research. (A) The walls are inserted perpendicular to the base, and gold pins are inserted into the base surrounding the prostate (prostate not pictured). (B) The replaceable parallel blades are inserted into the blade handle. (C) The blades pass between the gold pins in order to slice a 5 mm section of the prostate. Please click here to view a larger version of this figure.
n (%) | |
Hit (>40% tumor) | 59 (64%) |
Partial hit (5-30% tumor) | 6 (7%) |
Miss (0% tumor) | 27 (29%) |
Total | 92 (100%) |
Table 1: Tumor hit rate. Tumor hit rate was determined by a consultant pathologist specializing in prostate cancer, following review of H&E stained tissue. Tumor cell content of >40% was determined to be suitable for inclusion in the 100,000 Genomes Project, as per Genomics England guidelines.
Critical steps within this protocol include identification of tumor region for sampling, measurement of prostate, and tissue sampling. Firstly, measurement of the MRI to identify the correct area of the sampling is key. We demonstrate this method in the accompanying video; however, we also recommend confirming measurements with a radiologist in the first instance. Clear clinical notes which point the researcher towards the area of the MRI images that contains the index lesion are ideal. Secondly, measurement of the prostate should be carried out with care, ensuring that the ruler is held at an angle to measure the full length from base to apex, parallel to the anterior of the prostate. Thirdly, tumor areas should be confirmed prior to sampling by visually inspecting the tissue slice in relation to the original MRI image, palpating the tissue (in some cases the tumor area can feel more dense), and visually assessing the color of the tissue (in some cases the tumor will appear more pale than surrounding benign tissue).
This protocol has been carried out in full at UCL/UCLH by non-clinical postdoctoral researchers, a pathology fellow, pathology consultants, and research technicians. In our experience all steps of the protocol can be learned in under ten cases regardless of technical background. However, we recommend training from a radiologist regarding MRI measurement and training from a pathologist regarding slicing in the first instance. The protocol can be modified by using a 3D printed slicing handle, as previously published10.
Potential limitations of the technique include the risk of impeding on diagnosis. Slicing the prostate is a key step, which could impede on grading or positive margin rates if done incorrectly. There are two potential issues here. Firstly, if all of the index lesion is removed and used for fresh tissue experimentation immediately, routine clinical diagnostics will not be carried out for this lesion and the patient may be misdiagnosed as having a lower grade cancer. To avoid this, the researcher should discuss the sampling plan with the consultant pathologist who will routinely review the case, prior to sampling, and agree on the number, and location, of samples to be taken. Small tumors may be excluded locally for this reason. Secondly, if the prostatic capsule is not pinned down correctly to cork board prior to fixation, this could allow the inner tissue to bulge outwards during fixation, altering the surgical margins. This could lead to a false positive margin, where the remaining tumor appears to reside at the capsule purely due to tissue warping.
The significance of this technique with respect to existing methods lies mainly with tumor targeting. A range of methods for sampling radical prostatectomy specimens has been published to date; however, these all rely on a fully or partially random sampling approach1,2,3,4,5,6,7. The use of biopsy and in particular MRI data here has improved efficiency, allowing for reduced sampling with increased confidence of obtaining tumor tissue8.
Future applications of this method allow for the adoption of a wider range of downstream techniques than with previous sampling methods. For example, the availability of fresh tissue that has a high probability of being tumor means that more expensive and/or labor-intensive fresh tissue techniques can be utilized, as many samples are not required to ensure the presence of tumor. This can include and is not limited to, ex vivo culture, ex vivo MRI, advanced imaging and transcriptomics.
The authors have nothing to disclose.
The authors wish to acknowledge Prostate Cancer UK for funding SH under the Prostate Cancer UK Centre of Excellence and Travelling Prize Fellowship (TLD-PF16-004) and HP under INNOVATE (PG14-018-TR2). This work was supported by researchers at the National Institute for Health Research University College London Hospitals Biomedical Research Centre.
6 mm biopsy punch | Fisher Scientific | 13404607 | Disposable biopsy punches for removing 6 mm tissue samples |
Black Ink | Leica Biosystems | 3801753 | Tissue marking & margin dye |
Blue Ink | Leica Biosystems | 3801751 | Tissue marking & margin dye |
Chainmail hand glove | Arco | 1456803 | Chainmail gloves to protect hand during slicing |
Cork board | Fisher Scientific | 12396447 | Cork board for pinning prostate to following sampling procedure |
Needles | SLS (Scientific Laboratory supplies) | SYR6112 | Sterile needles to use to pin tissue to cork board following sampling |
Prostate slicing aparatus | Insitute of Cancer Research, London | NA – must be obtained under MTA | A kit containing the slicer handle, blades, spacer, base, walls and pins |