Labile organic carbon (LOC) and the potential carbon turnover rate are sensitive indicators of changes in soil nutrient cycling processes. Details are provided for a method based on fumigating and incubating soil in a series of cycles and using the CO2 accumulated during the incubation periods to estimate these parameters.
Management practices and environmental changes can alter soil nutrient and carbon cycling. Soil labile organic carbon, a readily decomposable C pool, is highly sensitive to disturbance. It is also the primary substrate for soil microorganisms, which is fundamental to nutrient cycling. Due to these attributes, labile organic carbon (LOC) has been identified as an indicator parameter for soil health. Quantifying the turnover rate of LOC also aids in understanding changes in soil nutrient cycling processes. A sequential fumigation incubation method has been developed to estimate soil LOC and potential C turnover rate. The method requires fumigating soil samples and quantifying CO2-C respired during a 10 day incubation period over a series of fumigation-incubation cycles. Labile organic C and potential C turnover rate are then extrapolated from accumulated CO2 with a negative exponential model. Procedures for conducting this method are described.
Due to its vital roles in carbon (C) and nutrient cycling and its sensitivity to soil change, soil LOC is an important parameter to measure as an indicator of soil organic matter quality. Forests and agroecosystems to a large degree depend on the mineralization of nutrients in soil organic matter as a source of nutrients. Management activities can change the pool size and turnover rate of soil organic C, resulting in changes in nutrient supply1. Soil organic C consists of two primary fractions of recalcitrant C, which has turnover rates of several thousand years, and LOC, which has turnover rates from a few weeks to a few years2,3,4. Soil labile C consists of readily decomposable substrates such as microbial biomass C, low-molecular-weight compounds (amino acids, simple carbohydrates) from plant rhizodeposition, and decomposition byproducts and leachates from plant litter1,4,5. Because soil labile C is readily decomposable, it is highly sensitive to management practices and natural phenomena that disturb or alter soil6. Soil labile C serves as the primary energy source for soil microorganisms in the decomposition of organic matter7. As such, LOC impacts nutrient cycling to a greater degree than does stable forms of soil organic C8. Soil microorganisms are also responsible for the majority of heterotrophic respiration that occurs during decomposition of recalcitrant soil organic matter facilitated by the priming effect of LOC9,10,11. This respiration plays a substantial role in global C cycles because soil organic C is approximately double that of atmospheric C11.
As a result of its importance in terrestrial ecosystems, several methods have been developed to estimate soil LOC. These methods can be delineated into three general classifications: physical, chemical, and biochemical. Densitometric separation methods are physical methods that consist of separating soil organic C into heavy or light fractions or into coarse and fine particulate organic C12,13,14,15. Separation methods are relatively easy to perform, but they do not often produce consistent results because these fractions vary with soil type mineral composition, plant material size and density, and soil aggregate consistency13,15. Separation methods also produce only quantitative information about LOC15.
Several chemical methods are available for LOC estimation. Aqueous extraction of organic carbon is relatively easy to perform, and the methods often provide easily reproducible results. However, these extractions do not involve the whole spectrum of available substrates for microorganisms15. Several oxidation methods for chemical fractionation of soil organic C have been developed. Oxidation methods have the advantage of characterizing the quantity and quality of labile organic C, although some methods require work with hazardous chemicals and there is variability among the methods in reproducibility of results15. The acid hydrolysis extraction method is another type of chemical fractionation procedure that can measure the quantity and quality of LOC, but results of this method do not facilitate interpretation of its biological properties13,15.
Biochemical methods for interpretation of soil LOC have been developed. Labile organic C can be measured as CO2 released by microorganisms in respiration assays. These assays provide estimates of true mineralizable organic matter, but typically only the most labile compounds are mineralized during the assays15. Soil microbial biomass C measured by fumigation-incubation16 and fumigation-extraction17 has been used to develop inferences about LOC. However, these procedures provide estimates of C in microbial biomass rather than LOC. Both fumigation procedures include subtraction of values from non-fumigated soil to determine microbial biomass C, but it has been suggested that values obtained without subtraction of non-fumigated soil provide a measure of labile organic fractions of C in addition to microbial biomass18.
The sequential fumigation-incubation (SFI) procedure13 for measuring LOC is a biochemical method adapted from the fumigation-incubation procedure16 for soil microbial biomass C measurement. The SFI method has some advantages relative to other methods of estimating LOC. A conceptual basis for the method is that LOC is the microbially degradable C that governs microbial growth and that LOC is physically accessible and chemically degradable by soil microorganisms. Under field conditions, microbial growth is typically limited by carbon availability, nutrient availability, available pore space, and/or predation. These factors are nearly eliminated by fumigation, creating unimpeded conditions for microbial growth. No nutrients are removed during the incubation period of the method. Over the course of multiple fumigation and incubation cycles, microbial growth becomes limited by C quantity and quality (lability)13. The accumulated CO2 respired during the incubation cycles is used to extrapolate LOC with a simple negative exponential model11,13,19. The potential C turnover rate can also be derived from the slope of the exponential model, so the SFI method has the advantage over most other LOC methods of simultaneously estimating the concentrations and potential turnover rate of LOC11. For other methods, information on the potential turnover rates of LOC can only be ascertained if tracers such as 14C are used13. The SFI method is thus a relatively simple and inexpensive technique for obtaining measurements of both LOC and its potential turnover rates.
1. Collect Soil to Get Samples Representative of Conditions within the Experimental Area and within Experimental Units20
2. Prepare Soil for the SFI Assay
3. Take Subsamples for Oven-dry Weight Determination
4. Fumigate Soil Samples
5. Assemble Containers for Soil Sample Incubation
6. Evacuate Chloroform from Desiccators Under a Fume Hood
7. Move Each Soil Subsample into an Incubation Container (Figure 1) to Conduct a 10 Day Incubation
8. Perform Titration on Each Subsample to Quantify CO2 Produced by Microbial Respiration during the Incubation Period
9. Determine Microbial Biomass C from Data Collected during the First Fumigation-incubation Cycle16,21,22
10. Determine Labile C and Potential C Turnover Rate Using CO2 Mineralized over the Course of the Eight Fumigation and Incubation Cycles
The SFI method has been used as described in this paper in a series of experiments conducted in the southeastern United States24,25,26,27. Together, these experiments encompassed a variety of vegetation types, including loblolly pine (Pinus taeda L.), switchgrass (Panicum virgatum L.), cottonwood (Populus deltoides Bartram ex Marsh.), and soybean (Glycine max L. Merr.). The method was sensitive at determining differences in LOC and/or potential C turnover rates among fertilization and cropping practice treatments in all studies. There was overlap in the range of LOC and potential turnover rates reported in this series of studies (Figure 2). Variations in the ranges of LOC reported in these studies highlight the sensitivity of the SFI method in detecting differences in labile C and potential C turnover. The loblolly pine and switchgrass alley cropping system had the greatest range of LOC among the vegetation types; the studies of this vegetation type encompassed the widest array of site conditions relative to the other vegetation types. The sites varied in soil type and age of the loblolly pine overstory from juvenile to late-rotation. The chronosequence of overstory age likely created the largest variation in organic matter inputs among the vegetation types presented here for representative results. The switchgrass pasture vegetation type was studied at the widest array of soil textures, and it also exhibited a relatively high variance in reported values. The soybean vegetation type had relatively high LOC values among site types, which was likely associated with the annual deposition of dead above- and below-ground biomass to the soil during its harvest. Loblolly pine plantations, which are characterized by relatively recalcitrant acidic pine litter as the dominant source of soil organic matter, exhibited the highest potential C turnover rates among the vegetation types selected here for representative results. The range of values reported in this series of studies is also within the range of those found in the range of soils used to develop the SFI method13 and in later experiments conducted with subtropical forests in China by one of the scientists that developed the SFI method11,28.
Figure 1. Incubation container for conducting sequential fumigation incubation procedure for labile organic C and potential C turnover rate determination. On the left is the Nalgene bottle, vial suspended from a stopper rod to contain NaOH, and a vial containing 30 g of soil shown separated for demonstration purposes. The container on the right has the soil and the stopper rod positioned within the Nalgene bottle with Parafilm along the top as would be done during incubation. Please click here to view a larger version of this figure.
Figure 2. Range of labile organic C and potential C turnover rate as measured with the sequential fumigation incubation method in different soil and vegetation conditions in the southeastern United States. Ranges reported are adapted in part from previous studies24,25,26,27. Vegetation types are: (1) loblolly pine plantation, (2) loblolly pine and bahiagrass pasture, (3) loblolly pine and switchgrass alley cropping system, (4) switchgrass pasture, (5) soybean, and (6) cottonwood plantation. Bars represent standard deviation. Please click here to view a larger version of this figure.
The SFI method is an effective protocol for detecting differences in soil LOC and potential C turnover rates over a range of management practices (such as fertilization, tillage, vegetation control, and harvest practices) and soil conditions. Soil LOC content and C turnover rate can be used to understand alterations of nutrient cycles. The SFI method also provides measurement of microbial biomass C from the first fumigation-incubation event. The ability to measure soil LOC, C turnover, and microbial biomass C concurrently makes the SFI method a relatively cost-effective analytical method.
Measuring additional soil parameters along with those collected with the SFI method can provide a broader understanding of the impacts of changes in LOC and its associated variables on nutrient cycling. Total C concentration of the soil provides the ability to determine changes in the size of the soil LOC pool relative to total C29. Including assays of soil enzymes facilitates understanding of microbial utilization of the labile C substrate that leads to changes in soil nutrient forms and quantities. For example, dehydrogenase plays a key function in organic matter degradation and is a useful indicator of overall microbial actitivity30. Urease and phosphatase are examples of enzymes associated with nutrient cycling because they are correlated with microbial transformations of nitrogen and phosphorus, respectively31,32.
There are variations in procedures of the SFI method, and the number of fumigation and incubation cycles is adjustable to different soil conditions. In the experiment in which the SFI method was developed, five or eight cycles were used for the array of tropical and subtropical forest soils tested13. In that experiment, five fumigation-incubation cycles were used for the Oa horizon and deeper mineral soil horizons of an Alfisol soil while eight cycles were used for Ultisol, Oxisol, Inceptisol, and Entisol soils. More recent experiments with the SFI method have used five28 and seven11 fumigation-incubation cycles. The key consideration for the number of cycles is whether CO2 accumulation plateaus over the course of the cycles. The SFI method fails to provide estimates of labile organic C and potential turnover if the negative exponential model does not fit the CO2 accumulation data. For some soil conditions, such a plateau can be reached within five fumigation-incubation cycles whereas for others more cycles are necessary. Preliminary testing of the SFI method on the soil conditions of interest can aid in determining the appropriate number of cycles necessary. Graphing CO2 accumulation trends for all samples after each fumigation-incubation cycle can also aid in determining accuracy of the number of cycles to be used.
Due to its dependence on CO2 accumulation to derive the LOC and C turnover rate, accurate measurements of CO2 evolution during incubation are essential to the SFI method. The long history associated with the use of the chloroform fumigation-incubation method from which the SFI method was developed has provided a number of recommendations to minimize potential errors. For example, the 10-day pre-incubation detailed in this SFI protocol description is recommended to allow the influence of soil disturbance to subside and for living fragments of roots to die in order to better isolate microbial CO2 evolution during the initial incubation period33,34. There are several alternatives for incubation container design, but essential components of design include a vial with NaOH to react with CO2 from microbial respiration, separate containers for the NaOH and soil, a source of moisture to prevent soil from drying during incubation, and seals to prevent contamination from ambient air during the incubation period22. Care must also be taken to avoid breathing near the vial of NaOH, which would partially neutralize the alkali and yield erroneous CO2 measurements, during incubation container assembly22. Sample depth in the incubation container can affect accuracy of CO2 measurements. In a test of soil sample depths within incubation containers, sample depths less than 4 cm had significantly greater inconsistency in CO2 evolution measurements than depths from 4 to 10 cm35. The higher inconsistency from the shallower depths was attributed to greater potential for soil drying during incubation, greater diffusion of O2 into soil, greater diffusion of CO2 out of the soil, and a lower potential for anaerobic microorganisms to contribute to decomposition. Soil pH may be another important consideration for the accuracy of CO2 accumulation measurements. After chloroform fumigation, recolonizing microorganisms during the incubation period are primarily bacterial populations. However, at soil pH values under 4.5, bacterial population development is inhibited. For the chloroform fumigation-incubation method, this effect leads to underestimation of soil microbial biomass C relative to that measured with other methods. Effects of soil pH on values yielded by the SFI method have not yet been tested, but precaution about using the method on low-pH soils may be warranted due to the known effects of pH on chloroform fumigation-incubation results.
The SFI method is one of several methods for measuring LOC, and it is important to distinguish measurements from this method relative to that of others. All LOC methods are an attempt to emulate natural processes of microbial degradation in soil to estimate LOC pool size, but these methods can differ in the portions of the LOC pool they sample and estimate36. In a study of labile organic pools in the Wuyi Mountains of China, LOC was measured with KMnO4 oxidation, aqueous extraction, physical fractionation, and the SFI method37. Measurements from each method were positively correlated with each other except for light fraction carbon as measured by physical fractionation. However, there were differences in the ranges of values derived from each method that were a function of the different components of the LOC pool each method measured. Generally, the magnitude of LOC values derived from each method was physical fractionation > KMnO4 oxidation > SFI > aqueous extraction. Physical fractionation was done as a measure of light fraction C, which is typically comprised of plant residues and animal remains. However, light fraction C can also contain charcoal and woody debris that decomposes relatively slowly; this LOC pool is an intermediate stage between plant residue and stable organic matter. Labile organic C values from KMnO4 oxidation (termed easily oxidized C) were approximately twice as large as those of the SFI method, which was attributed to the procedure sampling fractions of LOC with slower turnover than the SFI and aqueous extraction methods. Labile organic C measurements from aqueous extraction (termed water-soluble organic C) were approximately ten-fold lower than those of the SFI method. Due to microbial degradation of C being central to the SFI method, its LOC values were interpreted as microbial available C. These microbial available C values were greater than those of microbial biomass C measured in the same experiment, indicating that some of the C remaining in the soil after measuring microbial biomass C was available for mineralization by microbes. Greater values for LOC from the SFI method than those of microbial biomass C are consistent with several previous studies13,24,25,26,27. The SFI method has been used in several studies (which represent the majority of reported uses of this method to the authors’ knowledge) conducted in an array of locations, vegetation types, and soil conditions11,13,24,25,26,27,28,38. Given the apparent differences in the fractions of LOC pools measured by different methods, future applications of the SFI method should be done in concert with LOC methods that estimate different types of labile C as done in the Wuyi Mountain study36. Distinguishing LOC measured by the SFI method as microbial available C may be warranted to more precisely describe the type of LOC estimated by SFI. Inferences derived from the SFI method could also be improved by refining understanding of the portion of the LOC pool that is estimated by SFI and its roles in soil organic C and nutrient cycling processes.
The authors have nothing to disclose.
The authors gratefully acknowledge Michelle Gonzales, Kenny Kidd, Brad Osbon, and all other personnel that conducted the laboratory procedures for these data. The authors are thankful for assistance from Andrew Scott in developing software coding to conduct model-fitting procedures. The authors also appreciate the funding from the U.S. Department of Agriculture National Institute of Food and Agriculture, Sustainable Agriculture and Research & Education, Sun Grant South Central region, and the National Council of Air and Stream Improvement that made possible the studies from which representative results provided in this paper were drawn.
Soil auger sampling kit | JMC | PN039 | Several other manufacturers of punch augers are available |
Parafilm | Curwood | PM999 | |
Aluminum weighing boats | Fisherbrand | 08-732-103 | |
General purpose drying oven | Fisher Scientific | 15-103-0511 | Many other manufacturers of general purpose laboratory ovens are available |
10.5 L vacuum desiccator | Corning | 3121-250 | |
Glass scintillation vial | Wheaton | 968560 | |
Glass threaded vials, 41 mL | Fisherbrand | 03-339-21N | |
Chloroform, stabilized with amylenes | Sigma-Aldrich | 67-66-3 | |
Boiling chips | Fisher Scientific | S25201 | |
Glass rod | Fisherbrand | S63449 | |
Size 10 rubber stopper | Fisherbrand | 14-130P | Rubber stoppers can be purchased as solid and drilled in center to install glass rod or bought with a hole to insert glass rod |
Wide-mouth PPCO bottle, 0.5 L | ThermoScientific | 3121050016 | |
Sodium hydroxide, reagent grade | Sigma-Aldrich | S5881 | |
Barium chloride | Sigma-Aldrich | 202738 | |
Phenolphthalein indicator | Fisher Scientific | S25466 | |
Hydrochloric acid solution, 0.1 N | Fisher Scientific | SA54-4 |