Source: Servello, D., et al. A Microbiomechanical System for Studying Varicosity Formation and Recovery in Central Neuron Axons. J. Vis. Exp. (2018).
This video demonstrates the induction of axonal varicosities by applying micromechanical stimulus on neurons. The system comprises a micropipette attached to a syringe containing buffer via tubing. Using a micromanipulator, the micropipette is positioned above the neurons. Fluid pressure is then applied to induce varicosities in axons.
1. Setting Up the Puffing Pipette Apparatus
NOTE: There are five basic components to this set-up: the glass pipette, the tubing, the syringe, the micromanipulator, and the buffer (Hank's) Table 1. Any buffer that has physiologically relevant salt concentrations could be used in this set-up.
2. Calibrating the Pressure of the Pipette Utilizing a Stretchable-membrane System
3. Puffing to Induce Varicosities
Table 1: Hank's buffer recipe. This recipe prepares the buffer utilized in the puffing protocol and during live-cell imaging.
Hank's buffer (filter, pH = 7.4, store at 4 °C | |
150 mM | NaCl |
4 mM | KCl |
1.2 mM | MgCl2 |
1 mM | CaCl2 |
10 mg/mL | D-glucose |
20 mM | HEPES |
Table 2: Pipette pulling parameters. Provides the parameters to be set on the pipette puller to obtain an opening that is around 45 µm in diameter.
Pipette pulling parameters | |||||
Heat | Pull | Velocity | Delay | Pressure | Ramp |
501 | 0 | 15 | 1 | 500 | 530 |
Figure 1: Schematic and photograph of puffing apparatus. (A) Photographs showing the overall microscope set-up. (B) The puffing apparatus showing the glass pipette held by the micromanipulator and connected to the rubber tubing. (C) Phase contrast images with a focus on the plane of primary hippocampal neurons showing the shadow of the pipette in the bottom right. (D) The out-of-cell plane is focused on the puffing pipette tip. (E) Schematic of distances and calculated pressures for inducing varicosities. Scale bar = 50 µm.
The authors have nothing to disclose.
ubber tubing | Fisher Scientific | 14-169-1A | |
10cc plastic syringe and plunger | Becton Dickinson | ||
micromanipulator | Sutter Instruments | ||
Cell culture dish (35 mm x 10 mm) | Corning | 3294 | |
Model P-1000 Flaming/Brown Micropipette puller | Sutter Instruments | ||
Eclipse TE2000-U Mcroscope | Nikon | ||
Plan Fluor ELWD 20x lens | Nikon | 62933 | objective |
Apo TIRF 100x/1.49 oil lens | Nikon | MRD01991 | objective |
HEPES | Fisher Scientific | BP410-500 | |
D-glucose | Fisher Scientific | D16-500 | |
MgCl2 | Fisher Scientific | BP214-500 | |
NaCl | Fisher Scientific | S640-3 | |
KCl | Fisher Scientific | BP366-500 | |
CaCl2 | Fisher Scientific | C70-500 |