Encyclopedia of Experiments
Biological Techniques
JoVE 비디오를 활용하시려면 도서관을 통한 기관 구독이 필요합니다.  전체 비디오를 보시려면 로그인하거나 무료 트라이얼을 시작하세요.
Encyclopedia of Experiments Biological Techniques
Fluorescence Leakage Assay to Study Cell-Penetrating Peptide Interaction with Membrane

Fluorescence Leakage Assay to Study Cell-Penetrating Peptide Interaction with Membrane

내레이션 대본

To measure the fluorescence leakage, dilute the LUVs in 1 milliliter of HEPES Buffer 2 in a quartz fluorescence cuvette to a 100 micromolar final concentration, and add a magnetic stirrer to facilitate homogenization of the solution during the experiment.

Measure the LUVs alone during the first 100 seconds to assess the background fluorescence, before measuring the leakage as an increase in fluorescence intensity upon the addition of aliquots of peptide solution over the next 900 seconds.

To measure 100% fluorescence leakage as a positive control, add 1 microliter of Triton X-100 to the LUVs to solubilize the vesicles, resulting in a complete unquenching of the probe during the last 100 seconds of the analysis. Then, use the formula to calculate the leakage percentage at each time point.

Related Videos

Read Article