JoVE 비디오를 활용하시려면 도서관을 통한 기관 구독이 필요합니다.  전체 비디오를 보시려면 로그인하거나 무료 트라이얼을 시작하세요.
Temperature Gradient Assay: A Method to Test Temperature Preference in Drosophila Larvae

Temperature Gradient Assay: A Method to Test Temperature Preference in Drosophila Larvae

내레이션 대본

To test the temperature preference of Drosophila larvae, create a temperature gradient by heating one side of an aluminum assay plate and cooling the other. Aluminum has high thermal conductivity, meaning the heat is transferred efficiently, creating a stable linear temperature gradient. After the system has equilibrated, record the temperatures across the plate in same-sized temperature zones, then load the center of the plate with clean larvae.

Cover the entire system 세스 eliminate interference from bright light and start the trial. Larvae distribute through the gradient, avoiding aversive zones that are too warm or too cold, and settle in zones of favorable temperatures. This behavior is called thermotaxis. To assess the larvae’s temperature preference, record the number of animals in each temperature zone.

In the example protocol, we will see how 세스 set up a single-direction temperature gradient between 18 and 28 degrees Celsius, and how larvae are handled during the assay.

To prepare a single-directional gradient, first, create a humid ambient environment for the assay. Place two aluminum blocks connected 세스 separate water baths on wet paper towels 10 centimeters apart. The water baths need 세스 be warmed up in advance. Next, make 100 milliliters of 1% agarose and add 25 milliliters 세스 each assay plate on a level surface. Once the agarose has solidified, gently rub the surface with a melamine sponge 세스 make the surface slightly coarse.

Then, 세스 promote efficient temperature transfer, fill any gaps between the aluminum blocks in the assay plates with water delivered from a spray bottle. Now, place the assay plates on the aluminum blocks and make sure that the demarcations are 2 centimeters from either edge 세스 exactly match the edges of the aluminum blocks.

Next, spray a film of water onto the surface of the plates so the gels do not dry out. Next, cover the system with a cardboard box 세스 reduce evaporation and help stabilize the temperature of the gel surface. Wait for 5 세스 10 minutes 세스 allow the temperature 세스 equilibrate. Then, check the surface temperature on the plate in at least 12 locations 세스 ensure that there is an even temperature throughout, give or take 2 degrees Celsius. Then, replace the box cover until the assay is performed.

First, remove the cardboard box over the gel and quickly check the gel surface temperature. If the surface is dry, spray a small amount of water on the surface. If the gel is good, then load 100 세스 200 larvae at the center of each plate using a small paintbrush. Then, place a lid over each assay plate 세스 trap the larvae and cover the setup with a cardboard box 세스 prevent light exposure. The assay is now in progress.

After 10 세스 30 minutes, remove the cardboard box and the microplate lid. Then, photograph the plates from above 세스 record the position of the larvae. Place the box above the camera 세스 avoid reflection on the surface of the gel. To clean up the plate, aspirate all the larvae wherever they may have scattered.

Now, calculate the percentage distribution of larvae in each zone using image analysis software. Make lines every 2 centimeters based on the demarcations on the assay plate and count the number of larvae in each zone.

When counting, ignore larvae distributed in regions 0.5 centimeters from each edge. Gel thickness and temperature conditions are not uniform near the edge.

Related Videos

Read Article