We introduce the VacuSIP, a simple, non-intrusive, and reliable method for clean and accurate point sampling of water. The system was developed and evaluated for the simultaneous collection of the water inhaled and exhaled by benthic suspension feeders in situ, to cleanly measure removal and excretion of particulate and dissolved compounds.
Benthic suspension feeders play essential roles in the functioning of marine ecosystems. By filtering large volumes of water, removing plankton and detritus, and excreting particulate and dissolved compounds, they serve as important agents for benthic-pelagic coupling. Accurately measuring the compounds removed and excreted by suspension feeders (such as sponges, ascidians, polychaetes, bivalves) is crucial for the study of their physiology, metabolism, and feeding ecology, and is fundamental to determine the ecological relevance of the nutrient fluxes mediated by these organisms. However, the assessment of the rate by which suspension feeders process particulate and dissolved compounds in nature is restricted by the limitations of the currently available methodologies. Our goal was to develop a simple, reliable, and non-intrusive method that would allow clean and controlled water sampling from a specific point, such as the excurrent aperture of benthic suspension feeders, in situ. Our method allows simultaneous sampling of inhaled and exhaled water of the studied organism by using minute tubes installed on a custom-built manipulator device and carefully positioned inside the exhalant orifice of the sampled organism. Piercing a septum on the collecting vessel with a syringe needle attached to the distal end of each tube allows the external pressure to slowly force the sampled water into the vessel through the sampling tube. The slow and controlled sampling rate allows integrating the inherent patchiness in the water while ensuring contamination free sampling. We provide recommendations for the most suitable filtering devices, collection vessel, and storing procedures for the analyses of different particulate and dissolved compounds. The VacuSIP system offers a reliable method for the quantification of undisturbed suspension feeder metabolism in natural conditions that is cheap and easy to learn and apply to assess the physiology and functional role of filter feeders in different ecosystems.
Benthic suspension feeders play essential roles in the functioning of marine ecosystems 1. By filtering large volumes of water 2,3, they remove and excrete particulate (plankton and detritus) and dissolved compounds 1 (and references therein) and are an important agent of benthic-pelagic coupling 4,5 and nutrient cycling 6,7. Accurately measuring the particulate and dissolved compounds removed and excreted by benthic suspension feeders (such as sponges, ascidians, polychaetes, and bivalves) is fundamental to understand their physiology, metabolism, and feeding ecology. Together with pumping rate measurements, it also enables a quantification of the nutrient fluxes mediated by these organisms and their ecological impact on water quality as well as on ecosystem scale processes.
Choosing the appropriate method of measuring removal and production rates of particulate and dissolved compounds by suspension filter feeders is crucial for obtaining reliable data concerning their feeding activity 8. As pointed out by Riisgård and others, inappropriate methodologies bias results, distort experimental conditions, produce incorrect estimations of ingestion and excretion of certain substances, and can lead to erroneous quantification of the nutrient fluxes processed by these organisms.
The two most frequently employed methods to measure particulate and dissolved nutrient fluxes in filter feeders involve either incubation (indirect techniques) or simultaneous collection of ambient and exhaled water (direct techniques). Incubation techniques are based on measuring the rate of change in the concentration of particulate and dissolved nutrients in the incubated water, and estimating rates of production or removal compared to adequate controls 8. However, enclosing an organism in an incubation chamber can alter its feeding and pumping behavior due to changes in the natural flow regime, due to a decline in oxygen and/or in food concentration, or due to accumulation of excretion compounds in the incubation water 7,9 (and references therein). In addition to the effects of confinement and modified water supply, a major bias of incubation techniques stems from re-filtration effects (see for example 10). Although some of these methodological problems have been overcome by using the right volume and shape of the incubation vessel 11 or with the introduction of a recirculating bell-jar system in situ12, this technique often underestimates removal and production rates. Quantifying the metabolism of dissolved compounds such as dissolved organic nitrogen (DON) and carbon (DOC) or inorganic nutrients, has proven to be especially prone to biases caused by incubation techniques 13.
In the late 60s and early 70s, Henry Reiswig 9,14,15 pioneered the application of direct techniques to quantify particle removal by giant Caribbean sponges, by separately sampling the water inhaled and exhaled by the organisms in situ. Due to the difficulty to apply Reiswig's technique on smaller suspension feeders and in more challenging underwater conditions, the bulk of research in this field was restricted to the laboratory (in vitro) employing mostly indirect incubation techniques 16. Yahel and colleagues refitted Reiswig's direct in situ technique to work in smaller-scale conditions. Their method, termed InEx 16, is based on simultaneous underwater sampling of the water inhaled (In) and exhaled (Ex) by undisturbed organisms. The different concentration of a substance (e.g., bacteria) between a pair of samples (InEx) provides a measure of the retention (or production) of that substance by the animal. The InEx technique employs open-ended tubes and relies on the excurrent jet produced by the pumping activity of the studied organism to passively replace the ambient water in the collecting tube. While Yahel and colleagues have successfully applied this technique in the study of over 15 different suspension feeders taxa (e.g., 17), the method is constrained by the high level of practice and experience required, by the minuscule size of some excurrent orifices, and by sea conditions.
To overcome these obstacles, we developed an alternative technique based on controlled suction of the sampled water through minute tubes (external diameter < 1.6 mm). Our goal was to create a simple, reliable, and inexpensive device that would allow clean and controlled in situ water sampling from a very specific point, such as the excurrent orifice of benthic suspension feeders. To be effective, the method has to be non-intrusive so as not to affect the ambient flow regime or modify the behavior of the studied organisms. The device presented here is termed VacuSIP. It is a simplification of the SIP system developed by Yahel et al. (2007) 18 for ROV-based point sampling in the deep sea. The VacuSIP is considerably cheaper than the original SIP and it has been adapted for SCUBA-based work. The system was designed according to principles presented and tested by Wright and Stephens (1978) 19 and Møhlenberg and Riisgård (1978) 20 for laboratory settings.
Although the VacuSIP system was designed for in situ studies of the metabolism of benthic suspension feeders, it can also be used for laboratory studies and wherever a controlled and clean, point-source water sample is required. The system is especially useful when integration over prolonged periods (min-hours) or in situ filtrations are required. The VacuSIP has been used successfully at the Yahel lab since 2011, and has also been employed in two recent studies of nutrient fluxes mediated by Caribbean and Mediterranean sponge species 21 (Morganti et al. submitted).
The use of specific samplers, the prolonged sampling duration, and the field conditions, in which VacuSIP is applied, entail some deviations from standard oceanographic protocols for collecting, filtering, and storing samples for sensitive analytes. To reduce the risk of contamination by the VacuSIP system or the risk of modification of the sampled water by bacterial activity after collection, we tested various in situ filtration and storage procedures. Different filtering devices, collection vessels, and storing procedures were examined in order to achieve the most suitable technique for the analysis of dissolved inorganic (PO43-, NOx–, NH4+, SiO4) and organic (DOC + DON) compounds, and ultra-plankton (<10 µm) and particulate organic (POC + PON) sampling. To further reduce the risk of contamination, especially under field conditions, the number of handling steps was reduced to the bare minimum. The visual format in which the method is presented is oriented to facilitate reproducibility and to reduce the time required to efficiently apply the technique.
System overview
To sample in situ pumped water from suspension feeders with exhalant orifices as small as 2 mm, the pumping activity of each specimen is first visualized by releasing filtered fluorescein dyed seawater next to the inhalant orifice(s) and observing its flow from the excurrent aperture 16 (see also Figure 2B in 18). The water inhaled and exhaled by the study specimen (incurrent and excurrent) are then simultaneously sampled with the use of a pair of minute tubes installed on custom-built manipulator or on two of the "arms" of an upside-down flexible portable tripod (Figure 1 and Supplementary Video 1). The water inhaled by the study organism is collected by carefully positioning the proximal end of one tube inside or near the inhalant aperture of the study organism. An identical tube is then positioned inside the excurrent orifice. This operation requires good care to avoid contact or disturbance of the animal, e.g., by sediment resuspension. To begin the sampling, a diver pierces a septum in the collecting vessel with a syringe needle attached to the distal end of each tube, allowing the external water pressure to force the sampled water into the vessel through the sampling tube. The suction is initiated by the vacuum previously created in the vials and by the pressure difference between the external water and the evacuated sample container.
To ensure a clean collection of exhaled water and to avoid accidental suction of ambient water 16, the water sampling rate needs to be kept at a significantly lower rate (<10%) than the excurrent flow rate. The suction rate is controlled by the length of the tube and its internal diameter (ID). The small internal diameter also ensures a negligible dead volume (< 200 µl per meter of tubing). Sampling over prolonged periods (minutes to hours) makes it possible to integrate the inherent patchiness of most substances of interest. To ensure that samples are adequately preserved in prolonged underwater sampling sessions as well as for transportation to the lab, an in situ filtration is recommended for sensitive analytes. The selection of sampling vessels, filtration assembly, and tubing are dictated by the study organisms and the specific research question. The protocol described below assumes that a full metabolic profile is of interest (for an overview see Figure 2). However, the modular nature of the protocol allows for easy modification to accommodate simpler or even very different sampling schemes. For a full metabolic profile, the sampling protocol should include the following steps: (1) Flow visualization; (2) Sampling ultra-plankton feeding (plankton < 10 µm); (3) Sampling inorganic nutrients uptake and excretion (using in-line filters); (4) Sampling dissolved organic uptake and excretion (using in-line filters); (5) Particulate feeding and excretion (using in-line filters); (6) Repeat step 2 (ultra-plankton feeding as quality check); (7) Flow visualization.
When logistically feasible, it is recommended that the metabolic profile measurements are combined with pumping rate (e.g., the dye front speed method, in 16) as well as with respiration measurements. These measurements are best taken at the beginning and end of the sampling session. For respiration measurement, underwater optodes or micro-electrodes are preferable.
1. Preparatory Steps and Cleaning Procedures
2. Working Underwater
Figure 1. An example of correct installations of the VacuSIP: (A) sampling the ascidian Polycarpa mytiligera (Gulf of Aqaba, Red Sea) using a custom-built manipulator with the color code used green for inhaled and yellow for exhaled water samples (photo by Tom Shelizenger and Yuval Yacobi); (B) sampling the sponge Agelas oroides (NW Mediterranean Sea) with an osculum width of 3 mm, using the VacuSIP device. The color code used is yellow for inhaled and red for exhaled water samples. Please click here to view a larger version of this figure.
Figure 2. Overview of the VacuSIP technique described in the protocol section. The lab work is represented in yellow boxes, the fieldwork in blue boxes. Please click here to view a larger version of this figure.
Table 1. The overall average sampling rates (ml min -1) obtained with different containers used for water collections and different vacuum levels: the flasks were not vacuumed (none); EPA glass vials and HDPE vials were vacuumed half of their volume (½ volume); sterile plastic tubes were already vacuumed by the manufacturer. Working at 5-8 m depth, water temperature of 18-22 °C, using PEEK tubes of 79 cm length and of 25 µm internal diameter.
Table 2. Overview of the sampling vessel, fixative, in-line filter assembly, storage and analytical methods described in the protocol section. The analyzed compounds are: ultra-plankton abundance (plankton < 10 µm), silicate (SiO4), phosphate (PO43-), nitrite + nitrate (NO2– + NO3–), dissolved organic matter (DOM), ammonium (NH4+) and particulate organic matter (POM). All the sampling vessels have silicon septum cap and are vacuumed before sampling. The fixatives are: paraformaldehyde + glutaraldehyde (Glut + Parafor), orthophosphoric acid (H3PO4) and hydrochloric acid (HCl). The in-line filter assemblies used are: polycarbonate filter holders and polycarbonate membrane 0.2 µm filters (PC filter holder + PC membrane) and stainless steel filter holders and binder-free glass fiber filters GFF.
Optimization of seawater collection methods
Selection of collector vials and cleaning procedure
VacuSIP-compatible collecting vessels should have a septum that allows sampling to be initiated by piercing with a syringe needle. They should withstand the elevated underwater pressure (2-3 bars at typical scuba working depths), and should hold a vacuum. Many (but not all brands) of vials approved by the EPA for the analysis of volatile organics meet these criteria. Pre-cleaned vials approved for DOC and DON analysis are also available. To test the suitability of these vials for the collection and analysis of nutrients and to optimize cleaning procedures, high quality double distilled water was collected in acid-cleaned polypropylene tubes (PP tubes), newly purchased, in acid-cleaned high-density polyethylene vials (HDPE vials), and in EPA glass vials, all equipped with a polytetrafluoroethylene (PFTE) septum cap. The HDPE vials and polypropylene tubes were cleaned as described in section 1.5.2 above, and the EPA glass vials were cleaned by the manufacturer.
The amount of NH4+ found in EPA glass vials was relatively minimal (≤ 0.1 µmol L-1) and depends upon the high quality double distilled water standard quality. In contrast, NH4+ concentrations significantly increased (up to 3 and 7 fold, respectively) and exhibited a higher variability in acid-cleaned polypropylene tubes and in high-density polyethylene vials (ANOVA F(5,53)=7.183, p<0.001, Figure 3). There was no effect of high quality double distilled water contact with the silicon septum on the ammonium analysis.
Comparison of new glass vials versus cleaned/recycled glass vials
To test whether EPA glass vials could be utilized for nutrient analysis more than once, the NOx–, PO43-, and NH4+ concentrations in seawater samples collected in new EPA glass vials were compared to those collected in used EPA glass vials. The new EPA glass vials were pre-cleaned by the manufacturer, while the recycled glass vials were cleaned as described above (1.5.2). Recycled vials had significantly higher NH4+ concentration, up to 1.5 fold the level found in new glass vials (t test, p<0.001, n=5). No significant differences were found in NOx– and PO43- content between the samples collected in recycled vials and the samples collected in new glass vials (Figure 4).
Silicate collection and storing procedures
To determine the best sampling vessel for the analysis of silicate, high quality double distilled water was collected in non-cleaned and in acid-cleaned polypropylene tubes (PP tubes), in acid-cleaned high-density polyethylene vials (HDPE vials), and in EPA glass vials. The expected silicate concentration was close to zero, so values that deviated from the expected concentration were considered contaminated. The silicate concentration significantly differed between the samples collected in the different vials (ANOVA, F(3,19)=210.047, p<0.001), showing the lowest SiO4 concentration in the acid-cleaned HDPE vials. Borosilicate glass vials contaminated the samples, with the final SiO4 concentration increasing by up to 7 µmol L-1 (Figure 5).
Selection of filtration apparatus for dissolved organic matter (DOM) and nutrient analysis
To determine which filter apparatus produces the lowest blank in the analysis of dissolved organic (DOC and DON) and inorganic nutrients (NOx–, NH4+, PO43-), stainless steel filter holders were compared to polycarbonate in-line Swinney filter holders. With each filter holder type we tested both polycarbonate membrane and pre-combusted glass fiber filter. The combination of stainless steel filter holder and combusted glass fiber filter provided the lowest blanks, whereas the polycarbonate Swinney filter holder equipped with polycarbonate membrane clearly contaminated the samples by up to 9 fold. Increasing the wash volumes did not resolve this problem (Figure 6).
Figure 3. Ammonium concentration (µmol L-1, average ± SD) collected with different vials: (1) Uncleaned HDPE vial; (2) Cleaned HDPE vial; (3) Cleaned HDPE vial + Parafilm; (4) EPA glass vial; (5) EPA glass vial + Parafilm; (6) Cleaned PP tube. The Parafilm was placed to test whether the silicon septum may contaminate the water samples. For each treatment 9 samples of high quality double distilled water were analyzed. The samples were analyzed fresh. Significant differences were found between the four sampling vessels (ANOVA, F(5,53)=7.183, p<0.001, power test=0.992). Please click here to view a larger version of this figure.
Figure 4. Ammonium (NH4+), nitrite + nitrate (NOx–), and phosphate (PO43-) concentrations (µmol L-1, average ± SD) of seawater samples collected in new (dark) and recycled/cleaned (white) EPA glass vials. Seawater was collected at the Experimental Aquaria Zone of the Institute of Marine Science and was filtered with stainless steel filter holder and glass filter. The water samples were analyzed fresh. The asterisk (*) indicates that the difference is significant (t test, p<0.001, n=5, power test=1). Please click here to view a larger version of this figure.
Figure 5. Silicate concentration (µmol L-1, average ± SD) in high quality double distilled water collected in different vials: acid-cleaned PP tubes, PP tubes, acid-cleaned HDPE vials, new EPA glass vials. Significant differences were found between the four sampler materials (ANOVA, F(3,19)=210.047, p<0.001, power test=1). Please click here to view a larger version of this figure.
Figure 6. Examining the effect of different filtration assemblies and wash volumes on nitrite + nitrate (NOx– µmol L-1). Samples for NOx– were obtained by filtering the seawater samples with stainless steel (SS filter holder) or polycarbonate in-line Swinney filter holders (PC filter holder) equipped with either a polycarbonate membrane (PC filter) or a pre-combusted glass fiber filters. For the PC filters, different volumes (10, 30, 60, 90 and 120 ml) of 5% HCl and high quality double distilled water were used for washing the filter assembly, the washing volume is given in parenthesis in the figure legend. Values are expressed as mean ± standard deviation (n=5). Seawater was collected at the Experimental Aquaria Zone of the Institute of Marine Science and the samples were analyzed fresh after the filtration. Please click here to view a larger version of this figure.
Figure 7. Example of experimental results: inhaled (IN, black circle) and exhaled (EX, red triangle) paired water sample concentrations (µmol L-1) of different substances processed by the sponge Chondrosia reniformis in the Mediterranean Sea: (A) ammonium (NH4+); (B) nitrite + nitrate (NOx–); (C) phosphate (PO43-); (D) Silicate (SiO4); (E) dissolved organic carbon (DOC); (F) dissolved organic nitrogen (DON); (G) planktonic organic carbon (LPOC); (H) planktonic organic nitrogen (LPON). Please click here to view a larger version of this figure.
Figure 8. An example of a flow cytometry analysis of paired water samples drawn from the water inhaled (A,C,E,G) and exhaled (B,D,F,H) by the sponge Chondrosia reniformis: (A,B,C,D) phytoplankton populations; (E,F,G,H) heterotrophic bacteria. In A-B and E-F the sampling was clean and accurate (all planktonic groups were efficiently retained). C-D and G-H are examples of exhaled water contamination, showing low removal of all planktonic groups. Syn: Synechococcus sp., pico: autotrophic picoeukariotes, nano: autotrophic nanoeukaryotes, high: heterotrophic bacteria with high DNA content, low: heterotrophic bacteria with low DNA content. Please click here to view a larger version of this figure.
Supplementary Figure 1. Cell retention efficiency of different planktonic prey by the clam Chama pacifica: Prochlorococcus sp. (Pro), Synechococcus sp. (Syn), pico-eukaryotes (Pico Euk), nano-eukaryotes (Nano Euk). Error bars = 95% CI. Please click here to download this file.
Supplementary Video 1. Sampling the ascidian Polycarpa mytiligera using a custom-built manipulator with the color code used green for inhaled and yellow for exhaled water samples. Sampling tubes (PEEK, ID 54 µm, 75 cm long) are carefully placed in the exhalant and inhalant siphons of the ascidian. Water is than drawn into evacuated tubes at a rate of ~1 ml min-1. In this demonstration fluorescein dye is used to visualize the exhalant jet. Note that the exhalant sampling tube is placed well within the exhalant jet. Please click here to download this file.
Preparatory steps
Collector vials for DOM and nutrient analysis
Since collector vessels may interact with dissolved micro-constituents and the sampler walls may be a substrate for bacteria growth 30-34, different vials for DOM and nutrient collection were tested. Borosilicate is not recommended for silica quantification 33,35, since glass bottles can increase the initial concentration of silica by up to two fold if the samples are not quickly frozen 30. Our results demonstrate that using pre-cleaned EPA vials results in low concentration blanks for DOC, DON, and inorganic nutrients, most notably for ammonium.
DOC filtration and storage
Filtration is a required and, in many cases, is the first analytical step in marine chemistry and microbiology. While it is possible to filter the samples after collection in the lab, this procedure is not recommended for in situ work, where samples are collected underwater, often in remote locations, hours or days away from proper laboratory facilities. The use of in-line, in situ filtration minimizes sample handling and thus reduces the risk of contamination. In situ filtration also removes most of the bacteria and reduces the risk that the sample composition will be altered by bacterial metabolism during the prolonged sampling and transport time. The filtration assembly increases the dead volume of the sampling apparatus and may also be a source of contamination. A selection of the smallest possible filter holders (e.g., in-line Swinney filter holder 13 mm) and minute PEEK tubing (e.g., 254 µm ID) reduces the dead volume and the risk of contamination by ambient water.
If the proper filter is not used or if it is not washed carefully, artifacts and contamination of the water samples are likely to occur 32,36-39. Studies of DOC analysis showed that filters and filter holders made of organic compounds (polycarbonate and PFA-PTFE) may result in severe DOC contamination32,37, especially when not thoroughly flushed with high quality double distilled water 38. The present protocol and results follow these guidelines and also indicate that polycarbonate filter holders should be avoided.
In situ work and interoperation
The VacuSIP system is a direct sampling technique that facilitates the study of the metabolism of undisturbed suspension feeders in their natural environment and the quantification of their ecological role in the system. For experienced and equipped divers, the application of the VacuSIP method is simple and requires only short training. InEx VacuSIP experiments are designed for a 'within'-design statistical analysis (i.e., paired or repeated measure analysis), therefore controlling for most analytical artifacts including high blanks. The use of controlled suction ensures slow and adjustable sampling rates, thus preventing accidental contamination of exhaled water with ambient water. Where possible, the selection of work sites with low current and low turbidity is recommended and will ensure cleaner and more accurate results. The prolonged sampling time (minutes to hours) allows integration of the high patchiness that characterizes the benthic boundary layer. All these features ensure that when properly applied the VacuSIP method is highly robust, providing reliable and replicable results even when working with a small number of replicates. An example of typical results obtained from a Mediterranean sponge and Indo-Pacific clam species is shown in Figure 7 and Supplementary Figure 1.
As with any technique, the VacuSIP is not free of potential pitfalls. The most common problem is contamination of the exhaled water sample with ambient water. Reasons for these artifacts include high suction rate, tube dislodgments, and animal behavior. Proper selection of the correct sampling rate is dependent on prior estimates of the excurrent flow rate. Such estimates can be obtained by using the dye front speed method 16. Ideally, the suction rate should be kept below 1% of the pumping rate (e.g., 1 ml min-1 for a 6 L hour-1 pumping rate). To avoid contamination with ambient water, sampling rate should never be greater than 10% of the pumping rate.
To control for the sampling rate, the length and internal diameter of the intake tubing should be adjusted according to the planned work depth and water temperature. The Hagen-Poiseuille equation (see section 1.3.1 above) may be used as a guide. However, this equation should be considered as a first order approximation since ΔP and sampling rate decrease with sampling time and in-line filtration adds uncertainties. The use of evacuated containers, sometimes with unknown vacuum pressures, introduces further complications. An example of how sampling rates varies as a function of different evacuated containers with different vacuum, is shown in Table 1.
Reducing the sampling rate is easily achieved by adjusting the tube length and ID, with no technical limitations to this reduction (sampling rates of few microliters per hour are feasible). Nevertheless, experimenters should be aware of the slow sampling rate dictated by this limitation for animals with slow pumping rate and for small organisms or specimens. The immediate implication of slow sampling rate is the limited volume of water that can be collected during a single sampling session. This low volume will limit the number of analyses and replicates that can be run with these samples, and will thus also limit the information that can be obtained from these populations.
Tube dislodgement can be easily spotted and sampling can be aborted or restarted, provided that a diver is keeping constant watch. In contrast, cessation of pumping during sampling is not always easy to detect. This is true not only for sponges, but also for tunicates, bivalves, and polychaetes. In fact, contrary to common belief, events in which an ascidian or a bivalve stopped pumping were documented with no visible change in the siphon geometry (Yahel, unpublished data). Moreover, in some cases, tunicates can maintain active pumping with no mesh secretion (that is, no filtration is taking place).
Controlling the sampling rate is critical. In this respect the VacuSIP is better than other methods, especially when the study animals are relatively small or when they pump slowly. Syringes are particularly difficult to control 2. For instance, Perea-Blazquéz and colleagues (2012a) 40 used a syringe to sample the water exhaled by several temperate sponge species and surprisingly did not find a general pattern of ingestion/excretion of particular nutrients (NO2–, NO3–, NH4+, PO43-, SiO4). The lack of a clear pattern is likely a result of contamination of the exhaled samples with ambient water due to syringe use. Contamination is evident from the extremely low retention efficiency of pico plankton reported by Perea-Blázquez and colleagues (2012b) 41 for their sponges: 40 ± 14% of heterotrophic bacteria and 54 ± 18% of Synechococcus sp. For comparison, using the VacuSIP, Mueller et al. (2014) 21 reported a removal efficiency of heterotrophic bacteria of 72 ± 15% in Siphonodictyon sp. and 87 ± 10% in Cliona delitrix.
To verify sample quality and ensure that no contamination of the ambient water occurs, we strongly recommend to first analyze the pico and nano plankton samples using flow cytometry. This fast, reliable, and cheap analysis will provide immediate information of sample quality. It is very common for some prey taxa such as Synechococcus sp. to be removed at close to 90% efficiency 14,42 by sponges and ascidian. Significant deviations from this benchmark suggest that contamination might have occurred (Figure 8).
For reliable and clean sampling, make sure the experiment design satisfies seven simple rules: (1) perform a preliminary survey (including pumping rate estimates) and prepare the worksite well; (2) know the studied animals; (3) verify that the studied specimen has a well-defined excurrent aperture and accessible location; (4) verify that the studied specimen is pumping before and after each sample collection; (5) place the tube for the collection of the exhaled water slightly inside the excurrent aperture (Figure 1); (6) use sampling rate < 10% of the excurrent flow rate, 1% is highly recommended; (7) define a quality criterion and omit suspected InEx pairs.
Following these simple rules, the VacuSIP system offers a practical and reliable method of measuring how active suspension feeders process particulate and dissolved compounds in natural conditions, allowing accurate and comparable estimates that can be used to assess the functional role of filter feeders in different ecosystems around the world.
The authors have nothing to disclose.
We thank Manel Bolivar for his assistance in the fieldwork. We are grateful to the "Parc Natural del Montgrì, les Illes Medes i el Baix Ter" for their support to our research and sampling permissions. The underwater manipulator was designed by Ayelet Dadon-Pilosof and fabricated by Mr. Pilosof. This work was supported by the Spanish Government project CSI-Coral [grant number CGL2013-43106-R to RC and MR] and by a F.P.U fellowship from "Ministerio de Educaciòn, Cultura y Deporte (MECD)" to TM. This is a contribution from the Marine Biogeochemistry and Global Change research group funded by the Catalan Government [grant number 2014SGR1029] and ISF grant 1280/13 and BSF grant 2012089 to G. Yahel.
GorillaPod, Original | Joby | GP000001 | flexible portable tripod |
Flangeless Ferrule | IDEX Health & Science | P-200X | 1/16" in Blue/pk |
Male Nut | IDEX Health & Science | P-205X | 1/16" in Green/10pk |
Female to Female Luer | IDEX Health & Science | P-658 | |
Female-Male Luer | IDEX Health & Science | P-655 | |
Peek Tubing (250µm ID) | IDEX Health & Science | 1531 | 1/16" OD x 0.01in ID x 5ft lenght. Alternative ID can be used |
Two component resin epoxy | IVEGOR | 9257 | Mix well the two component resin before use |
(TOC) EPA VIALS | Cole -Parmer | 03756-20 | 40 ml glass vials. Manifactured also by Thomas Scientific (ref. number 9711F09) |
HDPE VIALS | Wheaton | 986701 (E78620) | 20 ml high-density polyethylene vials |
Vacuette Z no additive | Greiner bio-one | 455001 | pre-vacuum by the manufacturer |
Septum Sample Bottles | Thomas Scientific | 1755C01 | 250 ml glass bottles |
Septum Cap 1 | Wheaton | W240844SP (E7865R) | 22-400 for HDPE vials |
Septum Cap 2 | Wheaton | W240846 (1078-5553) | 24-400 for glass vials and bottles. Also manufactured by Thermo Scientific National (ref. 03-377-42) |
In-line stainless steel Swinney Filter holders | Pall | 516-9067 | 13mm of diameter |
PTFE Seal Washer | Pall | 516-8064 | ring for stainless steel filter holders |
TCLP Glass Filters | Pall | 516-9126 | binder-free glass fiber filters, 13mm of diameter, pore size 0.7µm |
Polycarbonate Filter Holders | Cole -Parmer | 17295 | 13mm of diameter |
Isopore Membrane Filters | Millipore | GTTP01300 | 13mm of diameter, pore size 0.2 µm |
Contrad 2000 Solution | Decon Labs | E123FH | highly soluble basic mix of anionic and non-ionic surfactant solution |
Sterile Syringe Filters | VWR International Eurolab S.L. | 514-0061P | 25mm of diameter , pore size 0.2 µm |
Fluorescein | Sigma-Aldrich | (old ref.28802) 46955-100G | 100g |
Holdex, disposable,sterile | Greiner bio-one | 450263 | sterile, single-use tube holder with off-center luer for Vacuette |
Sterile Needles | IcoGammaPlus | 5160 | 0.7mm x 30mm |
Cryovials Nalgene | Nalgene | V5007(Cat. No.5000-0020) | 2ml |
Cryobox carton | Rubilabor | M-600 | 145x145x55mm p/microtube 1.5 ml |
Orthophosphoric Acid | Sigma | 79617 | |
Paraformaldehyde | Sigma | P6148 | 500g |
Glutaraldehyde | Merck | 8,206,031,000 | 25%, 1 L |
Hand Vacuum Pump | Bürkle | 5620-2181 |