Selective damage of human leukemia cells can be achieved through a novel approach of applying low frequency ultrasound both with and without chemotherapeutic pretreatment of leukemic and normal hematopoietic cells.
Low frequency ultrasound in the 20 to 60 kHz range is a novel physical modality by which to induce selective cell lysis and death in neoplastic cells. In addition, this method can be used in combination with specialized agents known as sonosensitizers to increase the extent of preferential damage exerted by ultrasound against neoplastic cells, an approach referred to as sonodynamic therapy (SDT). The methodology for generating and applying low frequency ultrasound in a preclinical in vitro setting is presented to demonstrate that reproducible cell destruction can be attained in order to examine and compare the effects of sonication on neoplastic and normal cells. This offers a means by which to reliably sonicate neoplastic cells at a level of consistency required for preclinical therapeutic assessment. In addition, the effects of cholesterol-depleting and cytoskeletal-directed agents on potentiating ultrasonic sensitivity in neoplastic cells are discussed in order to elaborate on mechanisms of action conducive to sonochemotherapeutic approaches.
Ultrasound refers to any oscillating sound pressure wave with a frequency greater than the upper limit of human auditory capacities (~ 20 kHz)1. Low frequency ultrasound in the 20-60 kHz range has been utilized in the laboratory as a means of generating emulsions, preparing cellular samples for nucleic acid extraction, for tissue disruption, and for a variety of other tests. The utility of low frequency ultrasound has also been extended to the industrial setting for welding, cleaning various materials, and in materials processing. Commercially available ultrasound generators come in frequencies ranging from 18-60 kHz, and full-scale wattages from 100-1,200 W.
Although ultrasound has long been used in the clinical setting for diagnostic imaging, it has been applied as a therapeutic modality only recently. Ultrasound ≥1 MHz is capable of safely disrupting urinary calculi (kidney stones) and biliary calculi (stones in the gallbladder or in the liver) in patients to reduce symptoms2,3. This approach known as extracorporeal shockwave lithotripsy (ESWL) is now widely applied in the clinic (more than one million patients are treated annually with ESWL in the United States alone4), and offers a modality by which to non-invasively break up calculi with minimal collateral damage through the use of externally applied, focused, high intensity acoustic pulses2-4.
Due to the unique direct shearing forces, as well as cavitation bubbles generated by high intensity ultrasound, these methodologies have been examined in cancer therapy for the treatment of castration-resistant prostate carcinoma and pancreatic adenocarcinoma in an approach known as high intensity focused ultrasound (HIFU)5-8. In a manner very similar to ESWL, HIFU uses multiple ultrasound beams and focuses them on a selected focal area to generate temperatures of 60 °C or higher through the use of acoustic energy, inducing coagulative necrosis in the targeted tissue5. Although other modalities of thermal ablation currently exist (radiofrequency ablation and microwave ablation), HIFU offers a distinct advantage over these methods in that it is the only non-invasive hyperthermic modality5. HIFU has attained mixed results in the clinic and is currently only available in clinical trials8-11. Nevertheless, the limited success it has achieved, and the very promising in vivo data acquired from preclinical mammalian models have demonstrated the potential of ultrasound in cancer therapy.
In an effort to improve HIFU, researchers have attempted to combine ultrasound with appropriate antineoplastic agents to generate a form of sonochemotherapy. Sonodynamic therapy (SDT) is a promising novel treatment modality that has demonstrated impressive antineoplastic activity in both in vitro and in vivo studies1. It has been shown that ultrasound preferentially damages malignant cells based on the size differential between such cells and those of normal histology1,5. SDT incorporates specialized agents known as sonosensitizers to increase the extent of preferential damage exerted by ultrasound against neoplastic cells. While therapeutic applications of SDT have been previously examined, ultrasonic systems used typically employ higher frequency ultrasound (≥1 MHz), and the effects of low kHz frequency ultrasound has yet to be fully explored. Lower frequencies of ultrasound are often more proficient at producing inertial cavitation, a phenomenon that results in the destruction of cells due to the rapid collapsing of microbubbles, inducing physicochemical damage12-14. This difference in the generation of inertial cavitation between MHz and low kHz ultrasound has been attributed to the fact that lower wave frequencies enable microbubbles more time to grow by rectified diffusion in the expansion half cycle, consequently producing more violent collapses during the following compression half cycle12.
We have previously shown that U937 human monocytic leukemia cells are sensitive to low frequency ultrasound (23.5 kHz), and that this sensitivity can be markedly increased through the application of antineoplastic agents that perturb the cytoskeleton15. Further, we have demonstrated that cells are preferentially damaged based on size, with larger cells exhibiting higher ultrasonic sensitivity. In addition, normal human hematopoietic stem cells (hHSCs) and leukocytes at comparable cell sizes are much more resistant to sonication than their neoplastic counterparts15, tentatively suggesting that low frequency ultrasound may be used to preferentially damage malignant cells in the presence of normal tissue.
To further examine the unique properties of low frequency ultrasound for potential therapeutic use, we have developed cleaning and stabilization procedures to increase the efficacy and reliability of one of our current sonication systems, the Branson Model SLPe 150 W, 40 kHz Cell Disrupter, equipped with a 20 mm horn fitted into a 7.62 cm cup. In addition, we have been able to determine accurate sample cavitation energies, as well as consistent waveforms and amplitude within the 40 kHz range using a cavitation meter and oscilloscope with hydrophone. By refining and systematizing our protocols, we have been able to establish consistency in our experimental sonications, allowing us to quantitatively compare the sonic sensitivities of neoplastic and normal cells of different histogenetic lineages. Our protocol for the 40 kHz system is presented in extensive detail in order for interested laboratories to be capable of performing comparable experiments, and to evaluate our findings of the antineoplastic effects elicited by low frequency ultrasound. In addition, we examine the dose dependent effects of methyl-β-cyclodextrin (MeβCD; Figure 1), a cholesterol-depleting agent, on increasing the ultrasonic sensitivity of U937 and THP1 human monocytic leukemia cells.
1. Cleaning Cell Sonifier System
2. Reassembling the Cell Sonifier and Setting up the System
3. Assessing System Intensity and Function
4. Preparation of Cells and Medium
5. Cell Sonication
6. Assessing Cells for Damage Post-sonication
7. XTT Assay to Determine Cell Viability and Mitochondrial Activity of Treated U937 and THP1 Cells
System stability is paramount in obtaining repeatable and reliable results. The proper torque specification of 54.23 N.m achieved proper coupling of the transducer and sonotrode2, with the consistency of the waveform being assessed through the use of an oscilloscope and hydrophone (Figure 3A). Figure 3B depicts measurements inside the sample vial, and Figure 3C assesses stability within the cup horn. As expected, the amplitude was slightly reduced due to some energy being absorbed by the glass. However, the waveform was not perturbed or distorted in either panel B or C, which is necessary for reliable delivery of sonic energy to the sample. A waveform that does not appear as a clear singular sine wave indicates a faulty transducer or improper setup. This is expressed in Figure 3D which shows multiple aberrant waves, a clear absence of a sine wave, and a frequency reading not expected with a properly functioning system. The cavitation meter used to measure the cavitation energy generated (Figure 4) found the sound intensity to be 100-110 W/cm2 at 33% amplitude, and 125-130 W/cm2 at 50% amplitude.
Once the 40 kHz system was appropriately calibrated and assembled in its entirety (Figure 5), reliable cell destruction was readily attained, as determined by both the TC20 and Z2 counters (Figure 6). As expected, more extensive cell damage was observed in cell populations sonicated at 50%, rather than at 33% amplitude. Nevertheless, 33% amplitude is useful as a starting point to detect potential sonic sensitizing effects of administered agents, as it produces noticeable damage, but leaves room for more damage to be detected when agents are applied to assess their potentiation of ultrasonic sensitivity. This is demonstrated in Figure 7A, where the dose dependent effects of MeβCD on potentiating the ultrasonic sensitivity of U937 cells are presented. Although non-sonicated MeβCD-treated cells were very similar in viability to non-sonicated, untreated cells, the viability markedly dropped after three pulses of 1 sec 40 kHz ultrasound was applied. In addition, the decrease in viability after sonication appears to have been dose dependent, as 5 mM MeβCD produced the largest drop in cell count, followed by 1 mM, and then 0.5 mM MeβCD.
Similar effects on cell viability and mitochondrial activity were observed in both U937 and THP1 cells that were treated with varying concentrations of MeβCD prior to sonication, as assessed with the XTT kit (Figure 7B). Although THP1 cells appear to be slightly more sonic resistant than U937 cells, both human leukemia lines are damaged in a dose dependent manner. Higher concentrations of MeβCD and more pulses of ultrasound produced the lowest reduction of XTT to a soluble, brightly colored orange derivative for both U937 and THP1 cells, corresponding to lower cell viability and mitochondrial activity.
Figure 1. Molecular structure of methyl-β-cyclodextrin. (A) Complete structure of methyl-β-cyclodextrin (MeβCD). (B) MeβCD is a polymer of seven repeating units with a R group of either H or CH3. Molecular Formula: C56H98O35. Molecular Weight = 1331.36.
Figure 2. Properly torqueing the 40 kHz ultrasound system. (A) The horn and converter are removed from the cup prior to torqueing. (B) Position the slot wrench and torque wrench at their respective positions. (C) Apply 54.23 N.m of torque in a clockwise direction before reattaching the horn and converter to the cup.
Figure 3. Use of an oscilloscope to characterize the waveform of the ultrasonic system. (A) An oscilloscope with hydrophone can be used to evaluate amplitude and waveform consistency. (B) A recording taken with the cup directly above the horn at 1.5 cm and set at 33% amplitude. (C) The waveform pictured here is from a reading acquired when the hydrophone is placed within the 20 ml glass scintillation vial. The vial is positioned at 1.5 cm above the horn and again set at 33% amplitude. (D) An oscilloscope screenshot of a system with aberrant frequencies as would be expected with a faulty system or improper coupling of the horn converter union. Please click here to view a larger version of this figure.
Figure 4. Use of a cavitation meter to characterize the sound intensity of the ultrasonic system. The cavitation meter seen here is used to represent cavitation energy in W/cm2. This is a very important instrument for assessing consistency of energy with respect to the sample.
Figure 5. Key components of the 40 kHz ultrasound system. The ultrasonic system is shown complete with cup horn (A), heating apparatus (B), the converter (C), and sample positioning mechanism (D). This design allows for easy positioning of the sample (E) above the horn (F).
Figure 6. Effects of different levels of amplitude on the ultrasonic lysis of U937 cells using the TC20 and Z2 counters. Cells were sonicated with the 40 kHz cell dismembrator at 33% amplitude (100-110 W/cm2) or 50% amplitude (125-130 W/cm2) using three 1 sec pulses of ultrasound, with 1 sec spacing in between each of these pulses. (A) A screenshot from the Z2 counter software demonstrates the effect of sonication on U937 cells. (B) Data from the TC20 counter were compiled in a graph to demonstrate the reproducibility of the results. These data include the total and live cell counts, as well as the trypan blue assessed cell viability. Bars reflect the standard error of the mean (SEM) for 4 independent cell populations. Please click here to view a larger version of this figure.
Figure 7. Effects of methyl-β-cyclodextrin on potentiating the ultrasonic sensitivity of U937 and THP1 cells. (A) U937 cells were treated with varying concentration of MeβCD for 30 min prior to being sonicated with 40 kHz ultrasound (105 W/cm2) using three 1 sec pulses spaced 1 sec apart. Cell populations were grouped into ≥12 µm and ≥17 µm. (B) U937 or THP1 cells were again treated with varying concentrations of MeβCD for 30 min prior to being sonicated with the 40 kHz system using 1-3 pulses of 1 sec ultrasound spaced 1 sec apart. Cell viability and mitochondrial activity were assessed with the XTT kit. 100 µl of cells were seeded per well into a flat-bottom 96-well microtiter plate. The plate was incubated for 24 hr prior to the addition of XTT solution. Cells were then incubated for an additional 2 hr before the wavelength was read. Bars reflect SEM for 4 independent cell populations. Please click here to view a larger version of this figure.
To attain optimal results, special care should be taken to carefully position the sample and clean the converter-horn union. The placement of the sample in the horn is important for obtaining consistent cell destruction, as changing the distance from the horn will alter the acoustic foci, and therefore alter the energy the sample is exposed to. The acoustic energy within the cup horn can be mapped using the cavitation meter to find the position of maximum cavitation. In addition, the cavitation meter, along with the oscilloscope are vital for determining the sound intensity the cells are being exposed to, as well as the homogeneity of the waveform. Therefore, these instruments should be used to detect problems with the system, and help determine what troubleshooting may be needed to correct system instability.
As previously mentioned, the low frequency system may act to further degas the water throughout the experiment if not run for several minutes prior to sample sonication. This initial run must be performed to yield a relatively degassed sonication medium and thus consistent results during experiments. In addition, cells should not be sonicated at or near the maximum amplitude when assessing the efficacy of sonosensitizers, as the true extent of sensitization would be difficult to assess. Using 33% amplitude on the 40 kHz system is an ideal setting, as it produces notable damage, but provides sonosensitizers ample room to demonstrate their efficacy, as demonstrated with MeβCD against U937 and THP1 cells (Figure 7). These data also confirm that MeβCD sensitizes multiple leukemia lines to low frequency ultrasound in a dose dependent manner.
There have been a number of experiments done with higher frequency in the range of 0.75 MHz to 8 MHz showing evidence of intramembrane cavitation bubbles being generated through sonication17-19. However, questions still remain in regards to the exact mechanism of ultrasound-induced cell lysis18. We have shown a link between fluidizing the cytoskeleton and increased sonic sensitivity using low frequency ultrasound15, a phenomenon demonstrated by other laboratories20, 21. In addition, we have found that microfilament-disrupting agents such as cytochalasin B potentiate ultrasonic sensitivity in multiple leukemia lines, but not hHSCs or leukocytes22, suggesting that inhibition of actin polymerization may be a sonosensitizing mechanism of particular interest. We have also observed that vincristine, a microtubule-disrupting agent that inhibits tubulin polymerization23, 24, markedly increases the ultrasonic sensitivity of different leukemia types in vitro including acute myeloid leukemia, chronic myeloid leukemia, and acute lymphoid leukemia. By contrast, cytoskeletal-directed agents that stabilize cytoskeletal components (paclitaxel and jasplakinolide) appear to make cells resistant to sonication, reflected by lower rates of cell lysis22. Taken together, these data support the hypothesis that fluidizing the cytoskeletal components of neoplastic cells is indeed an important factor in increasing the efficacy of SDT25. The present study also demonstrates that cholesterol depletion may be another method by which to further potentiate the ultrasonic sensitivity of neoplastic cells, as MeβCD-treated U937 cells are markedly sensitized to 40 kHz ultrasound.
While our sonication protocols have demonstrated marked antineoplastic activity in vitro, the current methodology is limited to work in culture and small vertebrate models that are able to fit in the vials used for sonication. We have shown that zebrafish can be safely sonicated using pulsed low frequency ultrasound (20 kHz), and that their tolerance to chemotherapeutic agents is quantitatively comparable to doses tolerated by murine models26, suggesting that tumor-bearing zebrafish may be used in preliminary investigations to assess the in vivo antineoplastic activity of these protocols. Nevertheless, administering chemotherapeutic agents prior to sonication of mammalian models has been reported in the MHz range1, and such protocols can likely be extended to incorporate low frequency ultrasound, as well as cholesterol-depleting and cytoskeletal-directed agents.
Potential clinical applications of this form of SDT may involve extracorporeal blood sonication in which antineoplastic agents are administered intravenously (i.v.) prior to the blood being removed for sonication25. This method removes potential sound barriers posed by human anatomy, and may be an effective way to damage leukemic blasts, as well as metastases from solid tumors. It is also possible that cholesterol-depleting and cytoskeletal-directed agents could be used in HIFU protocols that are already being examined in the clinic in an attempt to improve the efficacy of this treatment modality.
The methods described in the present study are capable of assessing the value of potential sonosensitizers, and further system refinement may enhance this utility. However, there are many variables to be considered when using such ultrasonic devises, including power supply quality, acoustic foci, and individual variation among converters. Therefore, future research will focus on visualizing the sonic waves and understanding their influence on results. SDT has shown to enhance cell lysis in vitro and may prove to be clinically viable if more in vivo data in mammalian models are acquired. Experiments examining other potentially exploitable characteristics of malignant cells, as well as various combined modalities involving multiple agents and ultrasound continue in our laboratory.
The authors have nothing to disclose.
The authors would like to thank the staff of the Syracuse University Department of Physics workshop for their innovative assistance in matters relating to our system design.
Iscove's Modified Dulbecco's Medium w/ NaHCO3 & 25mM Hepes | Life Technologies | 12440079 | |
Amphotericin B Solution | Sigma-Aldrich | A2942 | |
Penicillin/Streptomycin 100x Solution | Life Technologies | 10378-016 | |
Fetal Bovine Serum | Sigma-Aldrich | 12105 | |
Branson SLPe 40kHz Cell Disruptor with 3" (25mm) Cuphorn | Branson Ultrasonics | 101-063-726 | sonication device |
Brisk Heat SDC Benchtop Digital temperature Controler w/ 1000mL Beaker Heater | Brisk Heat | SDCJF1A-GBH1000-1 | heater used for temperature control |
Beckman-Coulter Z2 Cell Sizer with AccuComp® Software | Beckman-Coulter | 6605700 | |
Bio-Rad TC20 Automated Cell Counter | Bio-Rad | 145-0102 | |
Gentamicin 50mg/mL | Sigma-Aldrich | G1397 | |
Trypan Blue Solution | Sigma-Aldrich | T8154 | |
Falcon 50mL & 25mL Vented Culture Flasks | Fisher Scientific | 353082 | |
Lonza L-Glutamine 200mM 0.85% NaCl | Lonza | 17-605C | |
Seal-Rite 1.5 mL Microcentrifuge Tubes | USA Scientific | 1615-5510 | |
Beckman-Coulter Accuvette ST 25mL Vials and caps | Beckman-Coulter | A35473 | |
AccuJet Pro Auto Pipet | BrandTech Scientific | 26330 | |
USA Scientific 10mL Disposable Serological Pipets | USA Scientific | 1071-0810 | |
Tip One 100uL and 1000uL Filter Tips | USA Scientific | 1120-1840, 1126-7810 | |
100uL Micropipette | Wheaton | 851164 | |
1000uL Micropipette | Wheaton | 851168 | |
BioRad Dual Chamber Counting Slides | Bio-Rad | 145-0015 | |
Forma Scientific Dual chamber water jacketed Incubator | Forma Scientific | 3131 | |
Tektronix DPO 2002B Digital Phosphor Oscilloscope | Tektronix | DPO2002B | used to measure the ultrasonic waveform |
PPB MegaSonics Model PB-500 Ultrasonic Energy Meter | PPB Megasonics | PB-500 | used to assess the sound intensity in W/cm2 |
Teledyne RESON TC4013-1 Hydrophone | Teledyne | TC4013-1 | connects to the oscilloscope |
Wheaton 250mL Flasks | Sigma-Aldrich | Z364827 | |
20mL Glass Scintillation Vials | Sigma-Aldrich | Z190527 | |
Beckman-Coulter Isotonic Saline Solution | Beckman-Coulter | N/A | diluent for Z2 counter |
Chloroform 99% | Sigma-Aldrich | C2432 | |
Ethanol 200 Proof Anhydrous | Sigma-Aldrich | 459836 | |
Mineral Oil | N/A | ||
XTT Cell Proliferation Assay Kit | ATCC | 30-1011K | |
96-Well Microplate Reader | Cole-Palmer | EW-13055-54 | |
U937 Human Monocytic Leukemia Cells | ATCC | CRL1593.2 | |
THP1 Human Monocytic Leukemia Cells | ATCC | TIB-202 |