In this protocol, we describe the full process of experimental myopia inducement in mice using newly designed eyeglasses and the technic needed for achieving stable and reproducible results in ocular parameter measurements.
Murine model of myopia can be a powerful tool for myopia research because of the comparatively easy genetic manipulation. One way to induce myopia in animals is to put clear minus lenses in front of eyes for weeks (lens-induced myopia, LIM). However, extant protocols for inducement and evaluation vary from laboratory to laboratory. Here, we described a highly practical and reproducible method to induce LIM in mice using newly designed eyeglasses. The method fixes the lens stably in front of the mouse eye while allows the lens to be taken off for cleaning or topical drug administration. The phenotype is robust and efficient, and the variance is small. The method described here can be applied to mice right after weaning which extends the possible duration for experiments. We also gave technical advises for achieving reproducible results in refraction and axial length measurements. We hope the step-by-step protocol described here and the detailed article can help researchers perform myopia experiments with myopia more smoothly and make the data comparable across laboratories.
The prevalence of myopia has increased dramatically recently, while the mechanism of its onset and progression are still largely unknow1. The most characteristic phenotype of myopia is the elongation of axial length (AL), which increases risk for retinal complications or even blindness2. To better understand the pathogenesis of myopia and develop effective treatments, robust myopic animal models and stable phenotype evaluation are necessary.
Briefly, two methods exist for inducing myopic states in animals: form-deprivation myopia (FDM) and lens-induced myopia (LIM)3. The former places diffusers in front of the eye or sutures the eyelid to obscure the image, which influences the normal development of the eyeball, resulting in a myopia phenotype. The latter places minus lenses in front of the eye to move the focal point behind the retina. The retina detects the shift of the focus and elongates the eyeball to realign the retina and focal point. For FDM, after the eyelid is closed or the diffuser has been fixed in front of the eye, almost no further maintenance is needed. For LIM, the lens needs to be taken off for cleaning in order to keep it transparent. Thus, FDM is relatively easy to be induced technically. However, the mechanisms of FDM and LIM are different, and which method mimics the myopia in human better is still under debate3. One of the strengths of LIM is the stronger phenotype compared with FDM, at least in the case of mice4.
Animals that have been used for inducing myopia include chicks5, monkeys6, tree shrews7, guinea pigs8, and mice4. Considering the possibility of genetic manipulation, abundant available antibodies, and low cost for breeding, mice could have been the first choice as the animal model of myopia. However, compared with other larger animals, fixing lenses or diffusers in front of the mouse eye is relatively difficult especially for young mice such as right after weaning. For the experiments that need topical drug administration or multiple interim eye measurements, it is also necessary for the frame to be removable. Another challenge is the small morphological change of mouse eyeball, which needs sophisticated technics and devices to evaluate. To date, different inducing and measuring protocols used in different research teams make it hard to compare and repeat the results across laboratories. A standard protocol with details is needed.
Previous works described multiple methods to fix lenses or diffusers in front of the mouse eye, such as gluing9, stitching10 and head-mounted goggle frame11,12. We combined the exist head-mounted goggle technics11,12,13 with our newly designed frame to develop an ameliorated protocol for inducing robust and efficient experimental myopia in mice. The protocol can be applied to young mice soon after weaning at postnatal day 21 (p21). We also optimized the processes for stable and precise evaluation of phenotypes including the refraction and AL. We hope this standardized protocol can help to make myopic mice a more easily accessible model for myopia research.
All procedures were approved by the Ethics Committee on Animal Research of the Keio University School of Medicine adhered to the ARVO Statement for the Use of Animals in Ophthalmic and Vision Research, the Institutional Guidelines on Animal Experimentation at Keio University, and the Animal Research: Reporting of In Vivo Experiments (ARRIVE) guidelines for the use of animals in research.
1. Assembling the Eyeglasses for Mice
2. Measurements of the Refraction and AL Baseline.
3. Fixation of the Frame onto the Mouse Cranium.
4. Initiation of the Myopia Induction and the Maintenance Afterwards
At first, check if all the necessary parts are prepared (Figure 1a). An example of a piece of assembled eyeglasses is shown in Figure 1b. Except for the main body of the frames and the nut, all other parts are disposable for each mouse. A set of completed eyeglasses is shown in Figure 1c. Change the angle between the two frames to fit the mouse with different ages.
An example of the refraction measurement is shown in Figure 2a. This is a mouse eye induced by a -30 D lens for 3 weeks starting from p21. Note that the gaze shall be controlled close to 0 degree in both x and y axis which means that the mouse is seeing right in front of the camera9. Figure 2b shows an example of a whole eye image taken by a SD-OCT system tuned for mice and the definition of each part of the eye. Generally, SD-OCT systems present actual measured value directly.
An image of the stick adhered to the mouse head is shown in Figure 3a. The border of the cut should be at least 3 mm away from the eye to avoid influencing the function of the eyelid. The stick stays on the mouse head until the end of the inducement and provides the foundation to fix the eyeglasses. The adhesive strength of the dental adhesive system is supposed to be enough for the fixation of eyeglasses during the whole experiment for about 3 to 4 weeks. Assemble the eyeglasses as shown in Figure 3b. Two pieces of eyeglasses should be fairly symmetrical.
Presentative results are shown in Figure 4. In this experiment, 0 D plano lenses were fixed in front of the left eyes as internal controls and -30 D lenses were fixed in front of the right eye to induce myopia (C57B6/J mice, inducement started from p21, n = 4). Refractions and ALs were measured once a week after the beginning of the inducement for three weeks. Compared with 0 D plano lenses, -30 D induced a strong myopic shift in both refraction and AL. The change of refraction reached to the peak in the first week and stayed flat for the following two weeks. The difference between the change of myopic eyes and control eyes in AL was significant from the first week and became larger and larger in the following two weeks.
Figure 1: The design of the skull-mounted eyeglasses. (a) All parts needed for assembling the mouse glasses. (b) An example of the position of the frame and the nail tip for the right side of the eye. (c) An example of one set of assembled glasses. Adjust the joint part to change the angle of the frames to fit for mice in different ages. This figure has been modified from Jiang, X. et al4, available under a Creative Commons Attribution 4.0 International License. http://creativecommons.org/licenses/by/4.0/. Please click here to view a larger version of this figure.
Figure 2: Sample images of the measurement of the refraction and AL. (a) An image of the refraction measurement for a myopic eye using an infrared photorefractor. (b) A sample image of an AL measurement of the mouse eye using a SD-OCT system and the definition of each part of the eye ball. This figure has been modified from Jiang, X. et al4, available under a Creative Commons Attribution 4.0 International License. http://creativecommons.org/licenses/by/4.0/. Please click here to view a larger version of this figure.
Figure 3: An image of one mouse after the surgery. (a) An example of one mouse after the surgery for adhering the stick. (b) One mouse with eyeglasses in both sides. This figure has been modified from Jiang, X. et al4, available under a Creative Commons Attribution 4.0 International License. http://creativecommons.org/licenses/by/4.0/. Please click here to view a larger version of this figure.
Figure 4: Presentative results of a three-week follow-up of myopia inducement in four mice using -30 D lenses and 0 D lenses as internal controls. (a) Changes of refractions for three weeks. A sudden change can be observed one week after the inducement. (b) In contrast, changes in AL were relatively mild. Asterisk marks showed the statistical significances between the eyes wearing 0 D and -30 D lenses in each week, respectively. *p < 0.05, **p < 0.01. Student t-test. Please click here to view a larger version of this figure.
Figure 5: Recommended flowchart for inducing myopia in mice. The flowchart showed here represent one possible pattern for inducing myopia in mice. Please click here to view a larger version of this figure.
To make sure the eyeglasses to be fixed stably on the mouse head, several steps in this protocol need to be paid great attention. The periosteum must be removed completely before using the dental adhesive system. The blood on the skull also need to be cleaned up with care. While a little fine tuning is acceptable right after the application of the adhesive, do not move the stick frequently before the adhesive system dry up. Follow the instruction of the adhesive system carefully, especially the ratio of each component of the final mixture. When grasp the mouse during the maintenance of the eyeglasses or the follow-up measurements after the surgery, do not grasp the stick with the body of the mouse together. The relative movement between the skull and the stick is the most frequent cause of the dropping down of the stick. With proper surgery and grasping skill, the number of individuals that drop down the stick would be less than one in a 3-week experiment including 20 individuals.
Hairs and food scraps may slip into the interval between the eye and the lens. This will not only influence the transparency of the lens, but also potentially damage the cornea surface physically. To keep the transparency of the lens, at least two times of cleaning are necessary each week. This will also give mice the chance to groom face to reduce the incidence of complications to the cornea. Leave a space for about 1 mm between the frame and the skin to allow the mouse to blink. The frame may make it hard for mice to reach the food outside the cage through the grid above. Therefore, it is recommended to put food on the floor of the cage directly. Change the cage into clean one for about twice a week will also help to keep the lenses clean. Dirty lenses become diffusers inducing myopia through form-deprivation mechanism. This may skew the data and make the result to be hard to interpret since evidences showed that FDM and LIM are different model systems in etiology3.
Due to the small size of the mouse eye, the measured eye parameters tend to be unstable. We recommend the infrared photorefractor developed by Dr. Schaeffel for the refraction measurement9 and a SDOCT system for AL4 (see Table of Materials). Both systems present enough information for judging the reliability of the measured value to ensure the repeatability of the measurement. For refraction, as argued in previous reports, it is extremely important to maintain the measurement on-axis4,14. Keeping the gaze control within ±3 degrees could receive stable results. To achieve this precise measurement, the tube of the SDOCT system might be helpful when tweaking the direction of the mouse eye. For AL measurement, the reflected light on the corneal vertex and the brightest boundary near the optical nerve are two reliable anatomical marks that ensure the repeatability of this measurement.
The protocol described here induced significant myopic states in mice within one week. Although the mechanism is still unknown, the change in refraction and AL are not necessarily parallel. Since the AL kept growing myopic after one week, we recommend the measurement to be done three times in total: before, one week and three weeks after the inducement. One of the example flowcharts for myopia induction is showed in Figure 5. Based on previous report4, starting from p21 and using – 30 D lenses are recommended for LIM. Experiments last for over 4 weeks may have high incidence of severe cornea complications that influence the measured value and accelerate the consumption of lenses. The most frequent complication is corneal scarring. Mice cannot clean their faces and eyelids wearing the frame, which might be the reason for the complication.
The device described in this protocol can be applied to mice right after weaning (p21). This may partially contribute to the strong phenotype observed4. The frame is removable without general anesthesia. This allows not only the researcher to clean up the lenses easily, but also make the topical drug delivery possible4. Another strength is that the lenses can be easily changed into diffusers or lenses with different diopters (e.g., plus lenses), which extends the possibilities of this method. One limitation of this method is that the surgery needs some practice before the frames can be adhered stably for the whole experiment. The measurements also need patience to collect reliable data.
Mice are irreplaceable animal model with its possibility of genetic manipulation and the low cost for breeding. We hope the protocol described here could make the experimental myopia in mice a more practical model for myopia research.
The authors have nothing to disclose.
We thank M.T. Pardue for advice on the SDOCT, F. Schaeffel for advice on measurements of refraction and corneal curvature, Mr. Sanshouo for recreating the three-dimensional frame data, M. Miyauchi; K. Tsubota; Y. Tanaka; S. Kondo; C. Shoda; M. Ibuki; Y. Miwa; Y. Hagiwara; A. Ishida; Y. Tomita; Y. Katada; E. Yotsukura; K. Takahashi; and Y. Wang for critical discussions. This work was supported by Grants inAid for Scientific Research (KAKENHI, number 15K10881) from the Ministry of Education, Culture, Sports, Science and Technology (MEXT) to TK. This work is also supported by the grant for myopia research from Tsubota Laboratory, Inc. (Tokyo Japan).
screw | NBK | SNZS-M1.4-10 | |
washer | MonotaRO | 42166397 | |
nut | MonotaRO | 42214243 | |
stick | DMM Make | none | designed by authers and output by the 3D printer rented from DMM Make. |
frame | DMM Make | none | designed by authers and output by the 3D printer rented from DMM Make. |
lenses | RAINBOW CONTACT LENS | none | customized for mice use by the company |
cyanoacrylate glue | OK MODEL | MP 20g | |
dental adhesive resin cement | SUN MEDICAL | super bond | contains the etching liquid used for removing the periosteum of the mouse skull |
infrared photorefractor | Steinbeis Transfer Center | none | designed and offered by Dr. Frank Schaeffel from university of Tübingen |
Spectral domain OCT | Leica | R4310 | |
Tropicamide, Penylephrine Hydrochloride solution | Santen | Mydrin-P | |
midazolam | Sandoz K.K. | SANDOZ | components for the anesthetic |
medetomidine | Orion Corporation | Domitor | components for the anesthetic |
butorphanol tartrate | Meiji Seika Pharma | Vetorphale | components for the anesthetic |
0.1 % purified sodium hyaluronate | Santen | Hyalein | |
atipamezole hydrochloride | Zenoaq | antisedan |