A pH-sensitive ratiometric dye is used in combination with confocal laser scanning microscopy and digital image analysis to monitor extracellular pH in dental biofilms in real-time.
The pH in bacterial biofilms on teeth is of central importance for dental caries, a disease with a high worldwide prevalence. Nutrients and metabolites are not distributed evenly in dental biofilms. A complex interplay of sorption to and reaction with organic matter in the biofilm reduces the diffusion paths of solutes and creates steep gradients of reactive molecules, including organic acids, across the biofilm. Quantitative fluorescent microscopic methods, such as fluorescence life time imaging or pH ratiometry, can be employed to visualize pH in different microenvironments of dental biofilms. pH ratiometry exploits a pH-dependent shift in the fluorescent emission of pH-sensitive dyes. Calculation of the emission ratio at two different wavelengths allows determining local pH in microscopic images, irrespective of the concentration of the dye. Contrary to microelectrodes the technique allows monitoring both vertical and horizontal pH gradients in real-time without mechanically disturbing the biofilm. However, care must be taken to differentiate accurately between extra- and intracellular compartments of the biofilm. Here, the ratiometric dye, seminaphthorhodafluor-4F 5-(and-6) carboxylic acid (C-SNARF-4) is employed to monitor extracellular pH in in vivo grown dental biofilms of unknown species composition. Upon exposure to glucose the dye is up-concentrated inside all bacterial cells in the biofilms; it is thus used both as a universal bacterial stain and as a marker of extracellular pH. After confocal microscopic image acquisition, the bacterial biomass is removed from all pictures using digital image analysis software, which permits to exclusively calculate extracellular pH. pH ratiometry with the ratiometric dye is well-suited to study extracellular pH in thin biofilms of up to 75 µm thickness, but is limited to the pH range between 4.5 and 7.0.
The method described here allows monitoring extracellular pH in dental biofilms in the range between 4.5 and 7, using the ratiometric dye seminaphthorhodafluor-4F 5-(and-6) carboxylic acid (C-SNARF-4) in combination with confocal laser scanning microscopy and digital image analysis. The employed fluorescent dye is pH-sensitive and displays a shift in its fluorescent emission depending on the state of protonation. The fluorescent emission of the protonated molecule peaks at 580 nm, and the emission of the deprotonated molecule at 640 nm1. The ratio of the fluorescent emission intensities in two detection windows comprising the two emission peaks (576 – 608 nm and 629 – 661 nm) thus reflects pH in the liquid phase, irrespective of dye concentration. With a pKa of ~6.4 the dye is suitable to visualize pH in moderately acidic environments.
PH in bacterial biofilms is of central importance for all metabolic processes. In the case of dental biofilms, pH in the extracellular matrix is the key virulence factor for the development of dental caries. Extended periods with low pH at the biofilm-tooth interface lead to slow demineralization of the underlying enamel2. Due to the complex three-dimensional architecture of biofilms, metabolites, including organic acids, are not uniformly distributed across the biofilm. Highly and less acidogenic microenvironments may be found in close spatial proximity3.
For decades, vertical pH gradients in biofilms were recorded with the help of microelectrodes4-6. While they offer a good spatial resolution due to their small tip size, they are not well-suited to monitor horizontal gradients. Moreover, insertion of the electrode disturbs the biofilm mechanically. Quantitative fluorescent microscopic techniques offer the advantage of visualizing pH changes in different areas of a biofilm without mechanical interference. Different microscopic fields of view can be selected freely and imaged repeatedly over prolonged periods1,7-9. However, when interpreting microscopic biofilm images, it is important to distinguish between fluorescence deriving from the microbial biomass and fluorescence deriving from the extracellular space. In acidic conditions, pH inside bacterial cells is different from pH in the extracellular matrix, as the bacteria actively transport protons across their cell membrane at the expense of adenosine triphosphate10. In the context of dental caries, intracellular bacterial pH does not have a direct impact on the underlying enamel whereas low extracellular pH leads to demineralization. Averaging pH in microscopic images that contain both bacteria-free areas and bacteria leads to erroneous results. The use of other stains along with the pH-sensitive dye in order to visualize the bacterial biomass and differentiate between extra- and intracellular areas brings about the risk of fluorescent contamination of the extracellular space and false measurements11.
The present manuscript therefore describes the use of the ratiometric dye in a double function; both as a pH marker and as a universal bacterial stain. As the dye is up-concentrated in bacterial cells, the combination of confocal microscopic imaging and an accurate digital image analysis procedure allows determining extracellular pH in the range between 4.5 and 7.0 in thin dental biofilms.
The experimental protocol was reviewed and approved by the Ethics Committee of Aarhus County (M-20100032).
1. Confocal Microscopic Calibration of the Ratiometric Dye
2. Collection of In Situ Grown Dental Biofilm Samples
3. Biofilm pH Imaging
4. Digital Image Analysis
The presented method allows monitoring extracellular pH drops in different microenvironments of dental biofilms in the pH range from 4.5 to 7 in real-time. If the experimental conditions are chosen as described above, pH starts to drop in all areas of the biofilms shortly after exposure to glucose.
When pH in a biofilm drops, bacterial cells become visible within short time (<1 min), as the ratiometric dye is upconcentrated in the cells (Figure 2A). In the very beginning, before acid production in the biofilm starts, no difference can be seen between background and cells. Images exported into the software daime have to be segmented with individually chosen brightness thresholds in order to obtain a good congruence between the bacterial biomass in the images and the objects recognized by the program (Figure 2B). If segmented appropriately, deletion of objects in daime removes all fluorescent signals that derive from bacterial cells (Figure 2C). Subsequent image processing in ImageJ results in green/red ratios for pixels in the extracellular space of the images. With the help of the calibration curve, these ratios can be converted to pH values and visualized with false coloring for graphic representation (Figure 2D). Average pH can be calculated for each of the processed images, and the pH development can be followed over time (Figure 2E). pH drops may differ between different microscopic fields of view, and both horizontal and vertical pH gradients can be monitored. However, under static conditions, within thin biofilms, only minor vertical pH gradients can be observed.
In some instances, the entire microscopic field of view might be covered with bacterial cells which renders calculation of extracellular pH impossible (Figure 3A). The problem might be resolved by choosing a slightly different focus plane. Care must be taken not to overexpose the microscopic images, because the bacterial biomass in the images then covers a larger area than in reality (Figure 3B). When segmenting the image in daime it is crucial to choose brightness thresholds that recognize all bacterial cells and, if present, human epithelial cells (Figure 3C) as objects. If segmentation is carried out with too high brightness thresholds, intracellular areas will be included in the pH calculation and lead to erroneous results (Figure 3D). Monitoring of extracellular pH with the ratiometric dye is limited by the use of confocal microscopy. Up to a penetration depth of 75 µm, extra- and intracellular areas can be distinguished reliably (Figure 3E). To measure vertical pH gradients in thicker biofilms, microelectrodes remain the method of choice.
Figure 1: Acrylic Splint for Intraoral Biofilm Collection. The splint is designed with buccal acrylic flanges connected by a lingual orthodontic wire that allows the volunteer to bite into normal occlusion. Please click here to view a larger version of this figure.
Figure 2: Image Processing for Microscopic Measurement of Extracellular Biofilm pH. (A) Confocal microscopic image of a biofilm stained with the ratiometric dye, 9 min after exposure to glucose. The bacterial biomass in the image can be distinguished from the extracellular background. (B) The same image after segmentation in daime. The entire bacterial biomass in the microscopic field of view has been recognized as objects during segmentation, as indicated by the orange lines. (C) The same image after removal of the bacterial biomass. All fluorescence deriving from bacterial cells has been removed, and only fluorescence deriving from the extracellular matrix is left in the image. (D) Graphic representation of extracellular pH in the same microscopic field of view. Green/red ratios have been calculated in ImageJ, and false coloring was applied for graphic representation of extracellular pH. Average extracellular pH = 5.86. (A-D) Scale bars = 20 µm. (E) Average pH drop in the same microscopic field of view, monitored for 15 min. The pH drop in this area of the biofilm is quickest in the beginning, shortly after exposure to glucose. Then it slows down but does not reach a plateau within the observation time. Please click here to view a larger version of this figure.
Figure 3: Microscopic Measurement of Extracellular Biofilm pH – Potential Problems and Mistakes. (A) Confocal microscopic image of a dense biofilm exposed to glucose and stained with the ratiometric dye. In this microscopic field of view, the entire image is covered with bacterial cells, and removal of the bacteria will not leave extracellular areas for pH calculation. (B) Overexposed confocal microscopic image of a biofilm stained with the ratiometric dye. During image segmentation of overexposed images larger areas than actually covered by bacteria are recognized as objects and part of the extracellular space is lost for pH calculation. (C) Biofilm image with epithelial cells (arrows). Brightness thresholds for image segmentation must be chosen, so that epithelial cells are recognized as objects and removed from the images prior to pH calculation. (D) The same biofilm image as in Figure 1B, segmented with a wrong brightness threshold. Part of the bacterial biomass is not recognized as objects and cannot be removed from the image. This leads to inclusion of intracellular areas in the pH calculation and consequently erroneous results. (E) Deep layer of a biofilm stained with the ratiometric dye. The image was acquired 90 µm from the biofilm-substratum interface. Differentiation between extra- and intracellular areas is compromised. Scale bars = 20 µm. Please click here to view a larger version of this figure.
Microscopic monitoring of biofilm pH provides several advantages, as compared to electrode or microelectrode measurements4-6. Microscopic techniques permit to determine pH with a high spatial resolution and allow capturing both horizontal and vertical pH gradients in biofilms without disturbing the biofilm mechanically. Previous attempts of microscopic pH monitoring, however, failed to differentiate between extracellular and intracellular pH in the biofilms1,7,9. Due to bacterial homeostasis, intracellular pH differs from extracellular pH, and pH calculations cannot be valid if both intra- and extracellular compartments contribute to the recorded fluorescent emission. The use of a second fluorescent dye along with the pH sensitive dye to visualize bacterial cells is problematic, since even a small overlap between the emission spectra of the dyes might compromise the quantification of fluorescent light. Therefore the technique presented here relies on a concentration gradient of the ratiometric dye between extra- and intracellular compartments of the biofilm to identify and later remove bacterial cells from the acquired pH images.
Upon staining with the fluorescent dye, bacterial cells in biofilms internalize and up-concentrate the molecule, but only in acidic conditions. pH ratiometry with the dye is therefore limited to the pH range between 4.5 and 7.0. At pH values above 7, the unprotonated and thus charged dye does not penetrate bacterial cells well enough to distinguish them from the extracellular background, and at pH values below 4.5 most of the dye molecules are protonated and no further changes in the fluorescent emission can be observed. The fitted curve (pH vs. Ratio green/red) is steepest around pH 6 and flattens out towards pH 4.5. An example is shown in Schlafer et al., 2015, Figure S2.11 At present the use of the fluorescent dye for pH ratiometry is limited to monitoring extracellular pH1. In principle, the dye might also be used to monitor intracellular bacterial pH changes, but so far, calibration has not been performed for intracellular use. Additionally, it would be difficult to distinguish accurately between intracellular fluorescent emission and fluorescent light deriving from dye molecules attached to the outside of the bacterial cell wall. Moreover, as staining with the ratiometric dye is used in combination with confocal microscopy, image acquisition in biofilm layers deeper than 75 µm from the cover glass/biofilm interface is compromised. Decreasing contrast between bacterial cells and extracellular matrix renders the differentiation between intra- and extracellular areas difficult. The employed ratiometric dye has been shown to reliably visualize 15 bacterial species associated with dental biofilm, and it stains all bacterial cells in dental biofilms grown in situ11. While it is likely that the ratiometric dye is a universal bacterial stain, this has not yet been proven and the stain needs to be tested on biofilms from other habitats than the oral cavity. The method does not permit to produce technical replicates of a given pH measurement, as image acquisition takes some seconds and biofilm pH changes dynamically. Repeated imaging of biofilm-free buffer solutions, however, and repeated imaging of biofilms in buffer yielded stable pH values (data not shown).
All steps of the above described procedure for image processing must be followed accurately. Biofilm images must be acquired with sufficient laser power/gain to obtain adequate levels of fluorescent signal in the extracellular matrix, but overexposure of bacterial cells should be avoided. If bacterial cells are overexposed (too high laser power or gain) larger areas than actually covered by bacteria are recognized as objects during image segmentation and part of the extracellular space is lost for pH calculation (see Figure 3B). On the other hand, if images are acquired with very low laser power/gain, fluorescent intensity in the extracellular space might not be sufficient for reliable calculation of green/red emission ratios. A Range Indicator tool in the microscope software might be used to adjust the microscope settings, so that bacterial cells are captured with maximum intensity, but without overexposure. Automated image segmentation must be controlled for all biofilm images to assure that all bacterial and, if present, eukaryotic cells are recognized as objects by the software. After segmentation, all biofilm images should be compared one by one to the respective unsegmented images to ascertain congruence between the bacterial biomass and the area recognized as objects. If larger areas than those covered by bacteria are recognized as objects the brightness threshold is too low for an accurate differentiation, and segmentation must be performed with a higher brightness threshold. If part of the bacterial biomass is not among the objects, the brightness threshold must be lowered to yield a correct differentiation between extracellular and intracellular space. For the analysis of large datasets it has proven advantageous to segment all images with a row of different brightness thresholds and to subsequently determine the ideal threshold for each image. Once a correct distinction between bacteria and extracellular matrix is achieved, no further problems are to be expected during image processing. There may, however, be some images with a very dense biofilm, where bacteria cover the entire microscopic field of view. In these images, obviously, extracellular pH cannot be determined. In some cases the problem can be resolved by acquiring images in a slightly different z-plane, where the bacterial biomass does not cover the entire field of view.
Further applications of extracellular pH ratiometry might be to study pH landscapes in other microbial communities than dental biofilms (i.e. Pseudomonas aeruginosa biofilms or current-producing bacterial biofilms). The effect of different ecological parameters, such as oxygen concentration, carbohydrate supply or application of electric current on biofilm pH might be determined. The influence of biofilm age, biofilm thickness and metabolic activity on pH might be investigated, as well as the effect of pH modulating agents on bacterial biofilms. The latter is particularly relevant in the context of dental biofilms, where buffering agents represent a promising therapeutic approach to control dental caries15. Moreover, future research should focus on applying the presented method under flow conditions. To date extracellular pH ratiometry has only been used to monitor pH under static conditions. Constant supply of fresh oxygenated medium is likely to have a considerable impact on the development of pH microenvironments and, in particular, vertical pH gradients within thin biofilms. The clearance of acids by medium flow might contribute to the establishment of vertical gradients even in very thin biofilms.
Ratiometric confocal microscopic imaging with the ratiometric dye C-SNARF-4 in combination with precise postprocessing of the acquired digital images permits to calculate and visualize biofilm pH in the extracellular matrix, in real time, in the pH range between 4.5 and 7.0 and up to a biofilm thickness of 75 µm.
The authors have nothing to disclose.
The authors would like to thank Javier E. Garcia and Lene Grønkjær for technical assistance and Merete K. Raarup for fruitful discussions. This work was funded by Aarhus University Research Foundation and the Simon Spies Foundation.
Zeiss LSM 510 META | Zeiss | N/A | |
C-Apochromat 63X water immersion objective | Zeiss | N/A | |
XL Incubator | PeCON | N/A | |
SNARF-4F 5-(and-6)-Carboxylic Acid | Life Technologies | S23920 | |
Dimethyl sulfoxide | Life Technologies | D12345 | |
HEPES | Life Technologies | 11344-041 | |
Costar 96-well black clear-bottom plate | Fisher Scientific | 07-200-567 | |
Custom-made glass slabs (4x4x1 mm; 1,200 grit) | Menzel | N/A | |
Alginate impression material | GC Corporation | N/A | |
Acrylic Adjusting Logic Sets/set of acrylic dental burs | Axis Dental | LS-906 | |
Orthodontic retainer containers | Spark Medical Equipment Co., Ltd | SK-WDTC01 | |
Sticky wax | Dentsply | N/A | |
Chewing paraffin wax | Ivoclar Vivadent AG | N/A | |
Dithiothreitol | Sigma Aldrich | D0632 | Used during preparation of salivary solution |
0.45 µm and 0.2 µm syringe filters | Sigma Aldrich | CLS431220; CLS431219 | |
daime | University of Vienna, Austria | http://dome.csb.univie.ac.at/daime | |
ImageJ | NIH, Bethesda, Maryland, USA | http://imagej.nih.gov/ij/ |