Because of the importance and extensive use of palladium, gold and cobalt metals in high-technology equipment, their recovery and recycling constitute an important industrial challenge. The metal recovery system described herein is a simple, low-cost means for the effective detection, removal, and recovery of these metals from the urban mine.
Developing low-cost, efficient processes for recovering and recycling palladium, gold and cobalt metals from urban mine remains a significant challenge in industrialized countries. Here, the development of optical mesosensors/adsorbents (MSAs) for efficient recognition and selective recovery of Pd(II), Au(III), and Co(II) from urban mine was achieved. A simple, general method for preparing MSAs based on using high-order mesoporous monolithic scaffolds was described. Hierarchical cubic Ia3d wagon-wheel-shaped MSAs were fabricated by anchoring chelating agents (colorants) into three-dimensional pores and micrometric particle surfaces of the mesoporous monolithic scaffolds. Findings show, for the first time, evidence of controlled optical recognition of Pd(II), Au(III), and Co(II) ions and a highly selective system for recovery of Pd(II) ions (up to ~95%) in ores and industrial wastes. Furthermore, the controlled assessment processes described herein involve evaluation of intrinsic properties (e.g., visual signal change, long-term stability, adsorption efficiency, extraordinary sensitivity, selectivity, and reusability); thus, expensive, sophisticated instruments are not required. Results show evidence that MSAs will attract worldwide attention as a promising technological means of recovering and recycling palladium, gold and cobalt metals.
Driving forces for the booming use of platinum group metals (PGM) are their extraordinary and sometimes exclusive properties, which make them essential components in a broad range of applications. PGMs can play a part in building a sustainable society, and these materials are used in a variety of contemporary applications and products: chemical process catalysis, automotive emissions control, information technology, consumer electronics, fine jewelry, preparation of dental materials, photovoltaic fuel cells, and lithium ion batteries (LIB)1-10. Over the past century, worldwide economic changes have been powered by the use of PGMs. Because of the importance of PGMs in clean technologies and high-technology equipment, the use of PGMs has increased dramatically in modern society. Because of the sharp increases in the use of PGMs, particularly in the production of electronic equipment, the accumulation of electronic waste (e-waste) has led to environmental challenges and concerns. Moreover, the recent surge in commodity prices has generated a new interest in the mining of e-wastes1-4.
E-wastes contain both hazardous materials and valuable palladium, gold and cobalt metals. If e-wastes are disposed of in landfills or not treated in an environmentally sound manner, they may pose a high risk of environmental damage. Palladium, gold and cobalt metals in e-wastes are a sustainable and "green" secondary resource of such metals5-10. Therefore, efficient processes for recovering palladium, gold and cobalt metals from e-wastes are urgently needed.
Future advancements in many technological fields will require control of primary metal resources. Because of the growing importance of palladium, gold and cobalt metals in industrial applications and solutions to environmental problems11-13, developing adsorption/extraction techniques for the recognition and recovery of such metals has become a top priority.
The main precious metals used in electronic products are silver, gold, palladium, platinum, and small quantities of rhodium4-8. Recovering palladium and gold has become crucial because of their unique combination of properties in a wide range of industrial applications, economic value, and rare occurrence. Market mechanisms have been influential in increasing the rates of collection and recycling of circuit boards of outdated PCs, TVs, mobile phones, and other electronic devices. Mass-produced consumer components, such as computer motherboards, contain approximately 80 g of Pd and 300 g of Au per ton of e-waste; the corresponding amounts for mobile phone handsets are 130 g of Pd and 200 g of Au per ton of e-waste5-10. This urban mine holds immense amounts of these metals (by comparison, Au and Pd are present in extremely low concentrations in rocks (~4 ng/g), soils (1 ng/g), seawater (0.05 µg/L), and river water (0.2 µg/L)14-16). To ensure a continuing and reliable supply of palladium, gold and cobalt metals for future technological innovations and new electronic equipment, it is important to develop an efficient and low-cost technology for recycling precious metals from e-waste. Such technology could serve as insurance against a future scarce availability of rare earth ores, which are predicted to be in short supply, or even exhausted, within 100 years.
An element such as cobalt has an essential input to nearly all of the electrochemical storage energy cells such as LIBs17-19. Because of the fast growth of information technology and a wide-range utilization of LIBs, the release of LIBs as e-wastes explored a new environmental challenge18-20. Therefore, handling these wastes with care by recovering these resources might open a new avenue in the environment and industrial applications.
Several powerful and well-established methodologies and analytical techniques have been used to discriminate and quantify Au(III), Pd(II), and Co(II) in natural ore and industrial waste, including flame and carbon furnace atomic absorption spectrophotometry, ultraviolet-visible (UV-vis) spectrophotometry, neutron activation analysis, and inductively coupled plasma mass spectrometry14-16,21-27. Despite their versatility and growing popularity, these analytical techniques suffer from many shortcomings. For example, they usually require careful planning and testing, involve many sample preparation steps to minimize interference from the sample matrix, require sophisticated instrumentation and well-trained individuals, and must be performed under rigorous experimental conditions17,21. Moreover, all of these analytical techniques incorporate pre-concentration and separation steps, such as solvent extraction, coprecipitation, ion exchange, and adsorption, to pre-concentrate the target metal ions from the matrix components prior to their determination20-27. Moreover, hydrometallurgy and pyrometallurgy techniques are commonly used in the recycle chain in industry19-22. Therefore, developing efficient, cost-effective and easy-to-use analytical methods to recover palladium, gold and cobalt metals from natural ore and industrial waste are important both for environmental protection and in the industrial sector11-13.
New technologies can offer new approaches to chemical analysis and recovery of metals from natural ore and industrial waste. Recent progress has been made in reducing the cost and shortening the time to fabricate optical chemical nanosensors/adsorbents; however, optical adsorbents are still used for specific real-world sensing, extraction, and recovery applications for a wide range of metals28-36. Recently, research has focused on tailoring specific solid mesoporous monoliths for use as highly sensitive sensors for the simple and simultaneous naked-eye detection and removal of toxic and precious metal ions, such as mercury and gold ions, from aquatic samples28-32. Here, a process for selectively detecting and efficiently recovering Au(III) and Pd(II) from the urban mine was reported; additionally, the process can be applied for the recovery of Co(II) ions from LIBs. Recycling metals by this process should not only serve as a secondary source of Au(III), Pd(II), and Co(II) ions but also reduce environmental pollution. The protocol designs of wagon-wheel-shaped MSAs show, for the first time, evidence of controlled optical recognition of Au(III), Pd(II), and Co(II) ions, and a highly selective system for recovery of Pd(II) ions (up to ~95%) in ores and industrial wastes.
1. Fabrication of Wagon-wheel-shaped, Cubic Ia3d Mesoporous Monolithic Scaffolds
NOTE: Control cubic geometry (preferentially gyroidal Ia3d symmetry) and micrometric particle surfaces of mesoporous monolithic scaffolds by using triblock copolymer Pluronic P123 [P123; poly(ethylene oxide-block-propylene oxide-block-ethylene oxide) (EO20PEO70EO20)] as a template.
2. Characterization of Materials
3. Fabrication of Pd(II)-MSA-1, Au(III)-MSA-2, and Co(II)-MSA-3
4. Batch Studies for Detecting Pd(II), Au(III), and Co(II) Ions
5. Method for Removing Pd(II), Au(III), and Co(II) Ions
6. Formation of Metal-to-ligand Binding Constants in Wagon-wheel-shaped MSAs
7. Selective-ion-extraction Experimental System
NOTE: Ensure specific and strong metal-to-ligand binding as follows:
8. Real Extraction of Metals from Urban Mine
Periodic gyroidal cubic Ia3d monolithic scaffolds and wagon-wheel-shaped MSAs with large cylindrical open pores (up to 10 nm in diameter) were fabricated using pressure-assisted direct templating with a P123 copolymer microemulsion system. TEM micrographs of the MSAs show wagon-wheel-like channels organized in large domain sizes and in different orientational geometries in the gyroidal bicontinuous cubic Ia3d mesostructures (Figure 1). Although the L1, L2, and L3 probes were directly physisorbed into the monolithic scaffolds (~80 mg of probe per gram of scaffold), the MSAs provided control over potential leaching out of the ligands upon washing, sensing condition assays, and chemical treatment during regeneration/reuse cycles.
Wagon wheel shape-like pores featured the cubic Ia3d structures of the MSAs, as evidenced by the TEM images (Figure 1). The HRTEM micrographs recorded along the dominant facet in the [111] direction indicate the formation of cubic bi-continuous surface morphology37-39. Six-fold symmetric channels with different nano-sized interconnections in wagon wheel shape-like pores were characteristics the cubic Ia3d lattice structures of MSAs (Figure 1, center)44. Furthermore, the agreement in the unit cell lattice determining by TEM micrographs (22.5 nm) with the unit cell parameter determined by small-angle XRD (a = d211√6) indicates the formation of the cubic Ia3d MSA morphology.
The appearance of pores of various geometrical shapes in this six-fold orientation around each wagon wheel pattern is the key feature of controlled Pd(II), Au(III), and Co(II) ion diffusion, adsorption, and recovery. Figure 2B indicates that uniformly shaped pore geometries and textural properties of the cubic Ia3d MSA-1, MSA-2, and MSA-3 were retained (surface area (SBET) of 560, 520, and 570 m2/g; pore volume (Vp) of 1.03, 0.98, and 1.09 cm3/g; and pore size (D/nm) of 8.2, 8.1, and 8.2 nm, respectively, as evidenced from N2 isotherm results). This retention of cubic Ia3d MSA structural integrity was used for the rational design of the MSAs, for which the Pd(II), Au(III), and Co(II) ions were detected with a fast response time, even at nanomolar concentrations (Figure 3-5). A sizeable number of organic moieties with potential functional active sites are strongly anchored onto the wagon wheel pore surfaces via H-bonding and dispersive interactions with retention of the cubic Ia3d geometry, as evidenced by the Bragg reflection planes (hkl) (Figure 2A). The formation of stable organic-inorganic hybrid MSAs with suitable accommodation of L1, L2, and L3 into the wagon wheel pores might lead to no leaching of ligands during the metal ion sensing/capture/removal assays and reusability/recovery process.
The specificity and sensitivity of the wagon-wheel-shaped MSAs for the target Pd(II), Au(III), and Co(II) ions were controlled by adjusting the pH to 2, 7, and 5.2, respectively. These specific pH values are the most suitable for the selective, sensitive, and efficient monitoring and removal of metal ions using MSAs (Figure 6A). The quantification procedure for sensing/capturing Pd(II), Au(III), and Co(II) ions with MSA-1, MSA-2, and MSA-3 involved detecting changes in color intensity at color response times (Rt) of 2, 3, and 5 min, respectively. To evaluate the sensitivities of the MSAs, color transitions in the reflectance spectra that could be detected by the human eye were carefully monitored over a wide range of metal ion concentrations (0-5,000 µg/L). Figures 6B-D show changes in color and reflectance intensity of MSA-1, MSA-2, and MSA-3 at λmax 384, 486, and 537 nm, respectively. These changes indicate metal-to-ligand binding events during the formation of the octahedral [Pd-(L1)2], square-planar [Au-(L2)], and octahedral [Co-(L3)2] complexes (the stability constants of these complexes are higher than those of competing-ion complexes; Figure 7).The reflectance spectral responses of the MSAs indicated the efficient detection/recognition of metals. In addition, Figure 6F shows that MSAs are very effective in removing and monitoring Pd(II), Au(III), and Co(II) ions from the urban mine and LIB solutions over a wide range of concentrations (from µg/L to mg/L) and even at the low-concentration limits of 0.19, 0.6, and 0.51 µg/L, respectively.
The ion-sensing/ion-removal efficiencies of the wagon-wheel-shaped MSAs toward Pd(II), Au(III), and Co(II) ions in the absence and in the presence of interfering ions were evaluated (Figure 7). Significant changes in the visible color patterns and reflectance spectra were evident, in most cases, upon addition of 1 to 18 competing ions [i.e., (G1) of K(I), Na(I), Li(I), Ca(II), Fe(III), and Cu(II); (G2) of Cd(II), Pb(II), Hg(II), Ni(II), Mn(II), Al(III); and (G3) of Bi(III), Zn(II), Dy(III), Er(III), Ho(III), and La(III)]to the Pd(II), Au(III), and Co(II) ion systems, confirming selective removal and efficient monitoring of the target (T) ions. Low concentrations of Ni(II), Cu(II), and Fe(III) ions interfered, but interferences were eliminated by using 0.3-0.5 M citrate/tartrate solution as a suppressing agent; no significant changes in the visible color patterns and reflectance spectra occurred upon addition of high concentrations of various cations at the optimal ion-sensing/capture conditions (pH 2, 7, and 5.2, 40 mg of the MSAs, 20 ml volume, 25 °C) (Figure 7). These findings indicated selective identification and capture of target ions in a wide range of real samples containing high concentrations of competing ions45,46.
The reusability of the wagon-wheel-shaped MSAs was assessed by examining the reflectance spectra of the target ion sensing/capture assays and determining the uptake efficiency (E %) as a function of regeneration/reuse cycle. The recycling process was carried out by stripping the Pd(II), Au(III), and Co(II) ions from the MSA surfaces (i.e., decomplexation). Decomplexation was accomplished by treating the Pd(II)-, Au(III)-, and Co(II)-MSAs with 0.1 M HClO4, 0.1 M thiourea in 1% concentrated HCl, and 2M HCl, respectively. The decomplexation treatment was carried out repeatedly to completely remove the Pd(II), Au(III), and Co(II) ions from the MSA surfaces. UV-vis spectroscopy and ICP-MS were used to confirm that the MSA surfaces were free of metal (Figure 8). Uptake efficiencies for MSA-1, MSA-2, and MSA-3 were calculated as % (CA/C0), where CA is the target ion concentration uptake by solid MSAs and C0 is the initial target ion concentration. Results indicated that the functionalities of the wagon-wheel-shaped MSAs were maintained over eight regeneration/reuse cycles46,47.
The recovery of Pd(II) and Au(III) from electronic scrap (i.e., PCI boards) and Co(II) from LIBs was carried out in several stages:
The first stage was the mechanical separation of grinded PCI board components.
The second stage included a pretreatment hydrometallurgical process, in which the PCI board chips (e-waste source) were leached in a mixture of 2 M H2SO4 and 0.2 M H2O2 at 90 °C for 6 hr to dissolve base metals (Cu, Fe, Ni, Al, Li, Mn, Co and Zn) and a suspension of partially dissolved plastic and Pd(II) and Au(III) ions8. After filtration of undissolved plastics, the residue was leached with a combined acid of HCl and HNO3 (3:1)at 70 °C for 3 hr to form a soluble solution of Pd(II), Au(III), Ag(I), Fe (III), Sn(IV) and Al(III) ions. The Fe (III), Sn(IV) and Al(III) ions precipitate by raising pH solution up to 4.5 using 2 M NaOH and filtered off. AgCl was precipitated using NaCl and filtered off (Figure 9). Additionally, the LIBs waste components were treated with HNO3, leading to a mixture of Co(II), Ni(II), Mn(II), Li(I), Fe(III), and Al(III) ions.
The third stage involved a series of batch experiments carried out under controlled experimental conditions. In these experiments, leach solutions were purified, Pd(II) and Au(III) ions were recovered from the electronic scrap solutions using MSA-1 and MSA-2 (see Figure 9), and Co(II) was recovered from the main products of the LIB solution using MSA-3 (Table 1). After removal, the filtrate was analyzed by ICP-MS.
In the fourth stage, the percentage uptakes of Pd(II) and Au(III) by MSA-1 and MSA-2 from a real urban mine composite mixture [0.119 mg/L Pd(II), 0.35 mg/L Au(III), 0.23 mg/L Ag(I), 7.05 mg/L Cu(II), 5.78 mg/L Ni(II), 13.35 mg/L Fe(III), 7.09 mg/L Al(III)] were determined. MSA-3 was used to estimate the recovery of Co(II) ions from a real LIB composite mixture [1.75 mg/L Co(II), 420 mg/L Ni(II), 350 mg/L Mn(II), 370 mg/L Li(I), 7 mg/L Fe(III), 1 mg/L Al(III)]. The efficiency of uptake of Pd(II), Au(III), and Co(II) ions by MSA-1, MSA-2, and MSA-3 was calculated as follows: E%= CA/Ce= C0 – Ce/C0, where CA is the target ion concentration uptake by solid MSAs, and Ce and C0 are the target ion concentrations in the equilibrated and initial solutions. Table 1 presents results for the real-sample study of the extraction of Pd(II), Au(III), and Co(II) using the MSAs; the percentage uptakes of Pd(II), Au(III), and Co(II) were approximately 79%, 68%, and 66%, respectively.
The fifth stage involved recovery experiments using stripping agents (Figure 3-5) to release Pd(II), Au(III), and Co(II) ions from the wagon-wheel-shaped MSA surfaces. The recovery efficiency (R%) was calculated as follows: R%= CR/CA, where CR is the target ion concentration released in solution by the stripping agent. ICP-MS analyses of the collected solutions indicated that >>98% of the metal ions were released by simple chemical stripping (Table 1). This result indicates that ultra-trace levels of Pd(II), Au(III), and Co(II) ions were extracted from the urban mine by the MSAs .
Figure 1. Investigation of wagon-wheel-shaped geometry. HRTEM micrographs of the wagon wheel pattern in the cubic Ia3d structures of the MSAs. Center: crystal shape.
Figure 2. Determination of mesostructured crystal lattice and surface parameters of wagon-wheel-shaped pores. XRD patterns (A) and N2 adsorption/desorption isotherms (B) of the wagon-wheel-shaped, cubic Ia3d MSAs.
Figure 3. Systematic engineering of the MSA-1. Fabrication of Pd(II)-MSA-1 and Co(II)-MSA-3 via the pressure-assisted method.
Figure 4. Systematic engineering of the MSA-3. Fabrication of Co(II)-MSA-3 via the pressure-assisted method.
Figure 5. Systematic engineering of the MSA-2. Fabrication of Au(III)-MSA-2 via the building blocks protocol.
Figure 6. Controlled pH-dependent Pd(II), Au(III), and Co(II) ion-sensing systems. (A) pH-response profiles of wagon-wheel-shaped MSA-1, MSA-2, and MSA-3 during the sensing and removal assays of target Pd(II), Au(III), and Co(II) ions. The efficiency of the reflectance spectra was monitored as a function of pH at λmax = 384, 486, and 537 nm, respectively. (B–D) Target ion concentration as a function of the reflectance spectra of MSA-1, MSA-2, and MSA-3, respectively. (E) Color maps for the MSAs with addition of 2 ppm Pd(II), Au(III), and Co(II). (F) Calibration plots of (R − R0) vs. [Mn+] for MSA-1, MSA-2, and MSA-3. Note: R and R0 represent the reflectance of the MSAs with and without the addition of target ions, respectively.
Figure 7. Study of the Pd(II), Au(III), and Co(II) ion-selective systems. (A–C) Selectivity of wagon-wheel-shaped MSA-1, MSA-2, and MSA-3 toward Pd(II) (2 mg/L), Au(III) (1 mg/L), and Co(II) (2 mg/L) ion-sensing and ion-removal assays. (D) Sequential color response ofMSA-1, MSA-2, and MSA-3 (blank; i.e., metal-free assay) toward target Pd(II), Au(III), and Co(II) ions upon addition of interfering ions in single, binary, and groups of ions (G1-G3).
Figure 8. Reusability of wagon-wheel-shaped MSAs. (A) Evaluation of the wagon-wheel-shaped, optical sensing/removal assays of the target ions after eight regeneration/reuse cycles (target ion concentration: 2 mg/L; pH and signal response time values for MSA-1, MSA-2, and MSA-3:pH = 2, 7, and 5.2,Rt = 2, 3,and 5 min; t = 25 °C). (B) Uptake efficiency vs. regeneration cycle number.
Figure 9. Real recovery of Pd(II) and Au(III) ions from electronic scrap solutions. Hydrometallurgical treatment of PCI boards and recovery of Pd(II) and Au(III) ions from electronic scrap solutions.
Target ions | Target ion-determination | Target ions (mg/L) | Coexisted metal ions (mg/L) | E % | R % |
Pd(II) | C0 | 0.119 | Ag (I): 0.23, Au(III): 0.35, Al(III): 7.09, Ni(II): 5.78, Fe(III): 13.35, Cu(II): 7.05 | 79 | 97 |
Ce | 0.025 | Ag (I): 0.225, Au(III): 0.351, Al(III):7.11, Ni(II): 5.77, Fe(III):13.32, Cu(II): 6.95 | |||
CR | 0.0913 | Ag (I): 0.00, Au(III): 0.001, Al(III): 0.00, Ni(II): 0.002, Fe(III): 0.005, Cu(II): 0.009 | |||
Au(III) | C0 | 0.35 | Ag (I): 0.23, Pd(II): 0.119, Al(III): 7.09, Ni(II): 5.78, Fe(III): 13.35, Cu(II): 7.05 | 68 | 98 |
Ce | 0.11 | Ag (I): 0.231, Pd(II): 0.118, Al(III): 7.00, Ni(II): 5.66, Fe(III): 13.29, Cu(II): 6.92 | |||
CR | 0.235 | Ag (I): 0.00, Pd(III): 0.002, Al(III): 0.00, Ni(II): 0.004, Fe(III): 0.003, Cu(II): 0.01 | |||
Co(II) | C0 | 1.75 | Ni(II): 420, Mn(II): 350, Li(I): 370, Fe(III): 2.00, Al(III): 0.40 | 66.3 | 95 |
Ce | 0.59 | Ni(II): 419.34, Mn(II): 350.06, Li(I): 370, Fe(III): 1.91, Al(III): 0.05 | |||
CR | 1.15 | Ni(II): 0.85, Mn(II): 0.00, Li(I): 0.00, Fe(III): 0.05, Al(III): 0.02 |
Table 1. Quantitative determination of metal ions in real samples. ICP-MS analytical data for the recovery of Pd(II), Au(III), and Co(II) ions in electronic scrap and LIB solutions.
Worldwide demand is growing for a means to accurately and rapidly detect, selectively recognize, and recover Pd(II), Au(III), and Co(II) ions from electronic scrap and LIB solutions. To address this issue, wagon-wheel-shaped, optical MSAs for chemical detection/removal/extraction and recovery of these metal ions were developed.
In designing the MSAs, two key factors were considered as follows: (1) receptors and (2) immobilization/transducing scaffolds. Receptors are organic ligands responsible for the selectivity of the MSAs; scaffolds are responsible for the stability, reusability, and sensitivity of the MSAs. Because of their highly uniform channels, large surface areas, pore size distribution, and controllable wagon-wheel structure, which is commonly associated with the [111] projection of the cubic bicontinuous surface morphology (Figures 1 and 2), the MSA-based wagon wheel Ia3d mesostructure material scaffolds provided control over the potential demands of this detection/removal/extraction and recovery method as follows: (1) stability of ligand-embedding HOM solid (i.e., no leaching out of the ligands upon washing), (2) sensing condition assays, and (3) chemical treatment conditions during the regeneration/reuse cycles (i.e., after eight cycles); high ligand-surface coverage and dispersion; mechanical robustness; and efficient recovery processability from urban mine.
To fabricate the stable and robust MSAs design, the monofunctionalization of the wagon wheel inner pore surface or successive inclusion of different ligands (i.e., L1, L2, and L3; Figures 3-5) into the HOM scaffolds can be achieved by pressure-assisted co-condensation; the high-order hybrids MSA-1 and MSA-3 were obtained using L1 and L3, respectively. Controlled design of MSA-2 was based on the fine-tuned surface patterning of the mesoscopic wagon wheel scaffolding architectures. This was accomplished by using a dispersible active agent (DDAB) that led to the dense decoration of L2 signaling centers inside the wagon wheel pore cavities. With these MSA designs, metal ions can interact with organic moieties by noncovalent bonding (e.g., hydrogen bonding), metal coordination, hydrophobic forces, van der Waals forces, π-π interactions, and electrostatic and/or electromagnetic effects (Figures 3-5). In sensing assays, nanoengineered MSAs can be triggered by a target Pd(II), Au(III),or Co(II) ion species and transduce measurable optical signals under synergistic pH, reaction temperature, and contact time (response time) conditions, enabling the binding of the metals into a hydrophobic or hydrophilic ligand pocket to be mimicked. The developed MSAs not only removed Pd(II), Au(III), and Co(II) ions from complex environmental matrices but also provided a means for a simple visual colorimetric estimate of the metal ion concentration; UV-vis reflectance spectroscopy sensitively quantified metal ion concentration over a wide range of concentration (Figures 3-6). Thus, MSAs provide a simple and sensitive colorimetric-based solution to detect changes over a wide range of metal ion concentrations as well as a means for the sensitive quantification of the target ions, thereby avoiding the need for sophisticated instruments. Even at ultra-trace concentrations (≤0.19 µg/L), a signal change in the reflectance spectra of the sensors appeared during formation of the complexes (Figure 1).
In batch sensing/removal/extraction systems, a major advantage of the wagon-wheel-shaped MSAs is their selectivity toward target ions, thereby preventing hindrance from interfering competing ions. Figure 6 confirmed the selective removal and efficient monitoring of Pd(II), Au(III), and Co(II) ions by the optical MSAs. The negligible change in the reflectance signals of the MSAs in the presence of competing ions indicated that weak chelates were formed between competing metals and L1, L2, and L3, specifically at pH 2, 7, and 5.2, respectively. The selectivity of the MSAs can be ascribed to the formation of highly stable octahedral [Pd-(L1)2], square-planar [Au-(L2)], and octahedral [Co-(L3)2] complexes.
For judging the cost-effectiveness, recyclability and durability of wagon-wheel-shaped MSAs after repeated regeneration/reuse cycles were investigated. Figure 8 shows that the MSAs retained a high efficiency for detection/removal/extraction of Pd(II), Au(III), and Co(II) ions over repeated regeneration/reuse cycles, although overall efficiency decreased slightly after the sixth regeneration/reuse cycle. The stability of the cubic Ia3d mesostructure and the incorporation of L1, L2, and L3 into the ordered wagon-wheel-shaped pores (induced by strong H-bonding and dispersive interactions) play significant roles in maintaining the functionality of the ion-sensing/capture system through several regeneration/reuse cycles (see Figure 7).
Recovering Pd(II), Au(III), and Co(II) ions from the urban mine can help limit the environmental damage associated with mining these metals, especially with respect to the impact on land and climate. Using real urban mine samples, results have shown that the MSAs described herein can selectively recover Pd and Au from e-waste, and Co from discarded LIBs (Table 1 & Figure 9), but practical, scalable process still remains challenge for the future applicability of the metal recovery from urban mine.
On the basis of the proposed management protocol, two key components play important roles in the enhanced metal ion accessibility, adsorption capacity, and recovery during the heterogeneous processes. First, the large surface-to-volume ratios and open cylindrical pores of the wagon wheel cubic Ia3d mesostructures (MSAs) promote orientational ligand assembly (as evidenced by the flexible interaction of Pd(II), Au(III), and Co(II) ions with L1, L2, and L3 and the high affinity of the metal-to-ligand binding events) (Figures 3-5). Second, the selective adsorption/detection/extraction processes mainly depend on the structure of the chelating agent, the experimental conditions (particularly pH), the composition of the ion system, the metal ion concentrations, and metal-to-ligand binding events. Although this protocol shows significant progress in the quality, and efficiency of the recovery methods, further efforts are required so that they can be used in other demanding applicability of environmental wastes, in which they enriched with high-doses of actively competitive metals such as Cu(II), Fe(III) and Ni(II) ions.
In conclusion, efficient, cost-effective, wagon-wheel-shaped MSAs have developed for recovering palladium, gold and cobalt metals from the urban mine. Results show evidence that MSAs will be useful in providing a route to a sustainable supply of gold, palladium, and cobalt to meet the needs of modern society.
The authors have nothing to disclose.
This work was supported by the Ministry of Education, Culture, Sports, Science & Technology and the Ministry of Environment, Government of Japan.
Tetramethylorthosilicate (TMOS) | Sigma–Aldrich Company Ltd. (USA) | CAS Number 681-84-5 | Molecular Weight 152.22; Linear Formula Si(OCH3)4; 218472-500G |
Poly(ethylene glycol)-block-poly(propylene glycol)-block-poly(ethylene glycol), PEG-PPG-PEG, Pluronic® P-123 | Sigma–Aldrich Company Ltd. (USA) | CAS Number 9003-11-6 | average Mn ~5,800 |
Sodium citrate tribasic dehydrate | Sigma–Aldrich Company Ltd. (USA) | CAS Number 6132-04-3 | Linear Formula HOC(COONa)(CH2COONa)2 · 2H2O; Molecular Weight 294.10; S4641-500G |
Pentadecane, C15 | Sigma–Aldrich Company Ltd. (USA) | CAS Number 629-62-9 | Linear Formula CH3(CH2)13CH3; Molecular Weight 212.41 |
3-(N-Morpholino)propanesulfonic acid (MOPS) | Tokyo Chemical Industry Con, LTD (TCI) | CAS Number:1132-61-2, Product Number M0707 | Linear Formula C7H15NO4S, M1254-250G, Molecular Weight 209.26 |
2-(cyclohexylamino) ethane sulfonic acid (CHES) | Tokyo Chemical Industry Con, LTD (TCI) | CAS Number:103-47-9, Product Number C0920 | Linear Formula C8H17NO3S, Molecular Weight 207.29 |
N-cyclohexyl-3-aminopropane sulfonic acid (CAPS) | Dojindo Chemicals (Japan) | 343-00484, Lot.DE132 | Linear Formula C9H19NO3S, M1254-250G, Molecular Weight 221.32 |
2-Nitroso-1-naphthol (NN) | Tokyo Chemical Industry Con, LTD (TCI) | Product Number N0267 | Linear Formula ONC10H6OH, M1254-250G, Molecular Weight 173.17 |
Sunset Yellow FCF | Sigma–Aldrich Company Ltd. (USA) | CAS Number 2783-94-0 | Empirical Formula (Hill Notation) C16H10N2Na2O7S2, Molecular Weight 452.37, 465224-25G |
Diphenylthiocarbazone | Sigma–Aldrich Company Ltd. (USA) | CAS Number 60-10-6 | Linear Formula C6H5NHNHCSN=NC6H5, Molecular Weight 256.33, 194832-10G |
4-hydrazinobenzoic acid | Sigma–Aldrich Company Ltd. (USA) | CAS Number 619-67-0 | Linear Formula H2NNHC6H4CO2H, Molecular Weight 152.15, 246395-25G |
Carbon disulfide | Sigma–Aldrich Company Ltd. (USA) | CAS Number 75-15-0 | Empirical Formula (Hill Notation) CS2, Molecular Molecular Weight 76.14, 335266-100ML |
Ethanol absolute | Sigma–Aldrich Company Ltd. (USA) | CAS Number 64-17-5 | Linear Formula CH3CH2OH, Molecular Weight 46.07, 24102-1L-R |
Small angle powder X-ray diffraction (XRD) | Bruker D8 Advance | Small angle powder X-ray diffraction (XRD) patterns were measured by using a 18 kW diffractometer (Bruker D8 Advance) with monochromated CuKα radiation and with scattering reflections recorded for 2θ angles between 0.1o and 6.5o corresponding to d-spacing between 88.2 and 1.35 nm. First, the powder samples were ground and spread on a sample holder. The samples were scanned in the range from 2θ = 0.1–6.5o with step size of 0.02o. To confirm the resolution of the diffraction peaks with standard reproducibility in 2θ (±0.005), the sample measurement was recorded by using both graphite monochromator and Göbel mirror detectors. Both detectors were used to generate focusing beam geometry and parallel primary beam. The sample measurement was repeated three times under rotating at various degrees (15o, 30o and 45o). | |
N2 adsorption–desorption isotherms | BELSORP MIN-II analyzer (JP. BEL Co. Ltd) | N2 adsorption–desorption isotherms were measured using a BELSORP MIN-II analyzer (JP. BEL Co. Ltd) at 77 oK. The pore size distribution was determined from the adsorption isotherms by using nonlocal density functional theory (NLDFT). Specific surface area (SBET) was calculated using multi-point adsorption data from a linear segment of the N2 adsorption isotherms using Brunauer–Emmett–Teller (BET) theory. Before the N2 isothermal analysis, all prepared samples were pre-treated at 100oC for 8 h under vacuum until the pressure was equilibrated to 10−3 Torr. | |
High-resolution transmission electron microscopy (HRTEM) | JEOL JEM model 2100F microscope | High-resolution transmission electron microscopy (HRTEM) was performed using a JEOL JEM model 2100F microscope. HRTEM was conducted at an acceleration voltage of 200 kV to obtain a lattice resolution of 0.1 nm. The HRTEM images were recorded using a CCD camera. In the HRTEM characterization, the sample was dispersed in ethanol solution using an ultrasonic cleaner, and then dropped on a copper grid. Prior to inserting the samples in the HRTEM column, the grid was vacuum dried for 20 min. Energy Dispersive X-ray micro-analyzers (EDX) were recorded by employing Horiba EDS-130S, which directly connected with Hitachi FE-SEM S-4300. Elemental mapping of all samples was carried out with the energy dispersive X-ray micro-analyzers with an acceleration voltage of 30 kV. Ten distinct spots were analyzed per sample, which resulted in 99% confidence bounds of ±0.01 in the molar fraction of each cation (with their sum normalized to unity). | |
UV-Vis-NIR spectrophotometer | Shimadzu 3700 | The absorbance spectrum of the nano-collectors material was measured by UV-Vis-NIR spectrophotometer (Shimadzu 3700). | |
Inductively coupled plasma mass spectrometry (ICP-MS) | Perkin Elmer Elan-6000 ICP-MS | In selective removal, metal ion concentrations were determined by ICP-AES. The instrument was calibrated using four standard solutions containing 0, 0.5, 1.0 and 2.0 mg/L (for each element) and the correlation coefficient of calibration curve was higher than 0.9999. | |
inductively coupled plasma atomic emission spectrometry (ICP-AES) | PerkinElmer Elan-6000 |