Source: Wang, J., et al. A Mouse Model of Vascularized Heterotopic Spleen Transplantation for Studying Spleen Cell Biology and Transplant Immunity. J. Vis. Exp. (2019).
The video demonstrates a surgical method for generating a mouse model of vascularized heterotopic spleen transplantation. The abdominal cavity of an anesthetized donor mouse is surgically opened to remove the spleen. The inferior vena cava and infrarenal aorta are identified, their lumbar branches are ligated, and openings are made for the heterotopic transplantation of a spleen from a congenic donor mouse. Upon completing vascular anastomosis and restoring blood flow to the implanted spleen, the incision is closed, and the mouse is monitored for recovery.
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board.
1. Surgical Preparation, Anesthetization, and Analgesia Regimen
2. Donor Spleen Harvest
3. Recipient Splenectomy and Spleen Graft Implantation
4. Animal Recovery
5. Post-surgical Pain Management
Figure 1: Donor spleen harvest. (A) Cauterize the short gastric vein attached to the spleen. (B) Place a small piece of sterile warm wet gauze over the spleen to keep it moist. (C) Dissect and isolate the portal vein behind the pancreas. (D) Ligate the side branches of the portal vein and place a suture round the portal vein distal to the splenic vein. The dashed lines represent the location transecting later for the anastomosis with the recipient IVC. (E) Flip the spleen over to the right side of the abdomen (surgeon's left) to expose the aorta and celiac trunk with its branches including splenic artery. (F) Dissect and mobilize aortic -celiac -splenic artery by ligating the two other branches. (G) Place a suture around the aorta proximal to the celiac artery. The dashed lines represent the location transecting later used for the anastomosis with recipient abdominal aorta. (H) After ligating the aorta and transecting the portal vein, perfuse the spleen graft with 10 mL of heparinized saline through the aorta.
Figure 2: Spleen graft implantation. (A) After isolation and cross clamping the aorta and IVC, make a longitudinal aortotomy and venotomy in the aorta and IVC, respectively. (B-D) Place the spleen graft on the right side of the abdomen (surgeon's left side). Make the end-to-side anastomosis between donor aortic cuff and the anterior wall of the recipient's aortotomy, using 2-3 bites of continuing suture. (E) Turn the spleen graft over to the left flank of the recipient; repeat the previous procedure between the donor aortic cuff and the posterior wall of the recipient's aortotomy and close the suture on the outside of aorta. (F-G) Make an end-to-side anastomosis between the donor portal vein and the posterior wall of the recipient's IVC, using 4 to 5 bites of continuous 11-0 nylon suture in the inside of the IVC and then close the suture on the outside of the IVC. (H) After completing the anastomosis, release the vessel clamps and place some cotton buds to help stop the bleeding.
The authors have nothing to disclose.
Ketamine | Wyeth | 206205-01 | |
Xylazine | Lloyd Laboratories | 139-236 | |
Heparin solution | Abraxis Pharmaceutical Products | 504031 | |
Injection grade normal saline | Hospira Inc. | NDC 0409-4888-20 | |
70% Ethanol | Pharmco Products Inc. | 111000140 | |
ThermoCare Small Animal ICU System | Thermocare, Inc. | ||
Adson Forceps | Roboz Surgical Instruments | RS-5230 | |
Derf Needle Holder | Roboz Surgical Instruments | RS-7822 | |
Extra Fine Micro Dissecting Scissors | Roboz Surgical Instruments | RS-5881 | |
Micro-clip | Roboz Surgical Instruments | RS-5420 | |
7-0 silk | Braintree Scientific | SUT-S 103 | |
11-0 nylon on 4-mm (3/8) needle | Sharpoint DR4 | AK-2119 | |
Ms CD45.2 antibody | BD Bioscience | 553772 | |
Ms CD45.1 antibody | BD Bioscience | 553776 | |
Ms CD11b antibody | BD Bioscience | 557657 | |
Ms B220 antibody | BD Bioscience | 553089 | |
Ms Ly6C antibody | eBioscience | 48-5932-80 | |
Ms Ly6G antibody | BD Bioscience | 561236 | |
Ms F4/80 antibody | BD Bioscience | 565614 | |
Ms CD11c antibody | BD Bioscience | 558079 | |
Ms CD3 antibody | eBioscience | 48-0032-82 | |
Ms CD4 antibody | BD Bioscience | 552051 | |
Ms CD8 antibody | BD Bioscience | 563786 | |
LIVE/DEAD™ Fixable Violet Dead Cell Stain Kit | Thermo Fisher | L34955 |
.