In this video, we demonstrate how to apply a conductance into a dopaminergic neuron recorded in the whole cell configuration in rat brain slices. This technique is called the dynamic clamp.
Neuroscientists study the function of the brain by investigating how neurons in the brain communicate. Many investigators look at changes in the electrical activity of one or more neurons in response to an experimentally-controlled input. The electrical activity of neurons can be recorded in isolated brain slices using patch clamp techniques with glass micropipettes. Traditionally, experimenters can mimic neuronal input by direct injection of current through the pipette, electrical stimulation of the other cells or remaining axonal connections in the slice, or pharmacological manipulation by receptors located on the neuronal membrane of the recorded cell.
Direct current injection has the advantages of passing a predetermined current waveform with high temporal precision at the site of the recording (usually the soma). However, it does not change the resistance of the neuronal membrane as no ion channels are physically opened. Current injection usually employs rectangular pulses and thus does not model the kinetics of ion channels. Finally, current injection cannot mimic the chemical changes in the cell that occurs with the opening of ion channels.
Receptors can be physically activated by electrical or pharmacological stimulation. The experimenter has good temporal precision of receptor activation with electrical stimulation of the slice. However, there is limited spatial precision of receptor activation and the exact nature of what is activated upon stimulation is unknown. This latter problem can be partially alleviated by specific pharmacological agents. Unfortunately, the time course of activation of pharmacological agents is typically slow and the spatial precision of inputs onto the recorded cell is unknown.
The dynamic clamp technique allows an experimenter to change the current passed directly into the cell based on real-time feedback of the membrane potential of the cell (Robinson and Kawai 1993, Sharp et al., 1993a,b; for review, see Prinz et al. 2004). This allows an experimenter to mimic the electrical changes that occur at the site of the recording in response to activation of a receptor. Real-time changes in applied current are determined by a mathematical equation implemented in hardware.
We have recently used the dynamic clamp technique to investigate the generation of bursts of action potentials by phasic activation of NMDA receptors in dopaminergic neurons of the substantia nigra pars compacta (Deister et al., 2009; Lobb et al., 2010). In this video, we demonstrate the procedures needed to apply a NMDA receptor conductance into a dopaminergic neuron.
1. Slice Preparation
2. Electrophysiological Recording
3. Conductance Application with Dynamic Clamp
4. Representative Results
A successful setup for application of a conductance using the dynamic clamp is shown in Figure 1A. Using this setup, we made a whole cell somatic recording from a dopaminergic neuron in the substantia nigra pars compacta. Dopaminergic cells typically fire spontaneously at low rates with a pacemaker-like pattern. A burst of action potentials can be evoked by phasic application of a NMDA receptor conductance with dynamic clamp (Figure 1B).
Figure 1: Application of a NMDA receptor conductance using the dynamic clamp technique. A. Hardware setup illustrating the connections between the intracellular recording rig and dynamic clamp computer. B. A burst of action potentials is evoked by application of a 40nS NMDA receptor conductance in a whole cell recording from a substantia nigra pars compacta dopaminergic neuron.
The dynamic clamp technique demonstrated here improves upon the traditional technique of direct current injection by allowing the experimenter to mimic the electrical effects of the activation of a receptor. In this video, we have shown that one can add the effects of activation of an NMDA receptor to the spontaneous activity of the dopaminergic neuron, i.e. a burst of action potentials are evoked.
Due to the flexibility of the hardware/software implementation, a variety of extensions can be used. The sign of the injected current can be switched from negative to positive, representing a scenario where the effects of activated receptor is removed from a neuron. Model neurons, represented in the form a series of differential equations, can also be numerically solved and allow the experimenter to investigate small networks.
The authors have nothing to disclose.
This work was supported by MH084494 (CJL), and MH079276 and NS060658 (CAP).
Material Name | タイプ | Company | Catalogue Number | Comment |
---|---|---|---|---|
K-gluconate anhydrous | Reagent | Sigma-Aldrich | ||
HEPES | Reagent | Fisher Scientific | ||
CaCl2 X 2H2O | Reagent | Fisher Scientific | ||
Ethylene glycol-bis(B-aminoethyl ether)-N,N,N’,N’-tetraacetic acid | Reagent | EGTA; Sigma-Aldrich | ||
MgATP | Reagent | MP Biomedicals | ||
NaGTP | Reagent | MP Biomedicals | ||
MgCl2 | Reagent | Sigma-Aldrich | ||
NaHCO3 | Reagent | Sigma-Aldrich | ||
KCl | Reagent | Fisher Scientific | ||
NaH2PO4, Anhydrous | Reagent | Fisher Scientific | ||
Glucose | Reagent | Acros Organics | ||
NaCl | Reagent | Fisher Scientific | ||
CholCl | Reagent | Sigma-Aldrich | ||
Sodium Pyruvate | Reagent | Fisher Scientific | ||
Ascorbic Acid | Reagent | Acros Organics | ||
Glutathione | Reagent | Sigma-Aldrich | ||
Olympus BX51WI Microscope (with 40x objective) | Microscope | Olympus | ||
2 A/D converters | Equipment | e.g. Heka Instruments Inc. ITC-18, National Instruments BNC-2090A | ||
Multiclamp 700B with CV-7B headstage | Equipment | Molecular Devices | ||
P-97 Flaming/Brown Micropipette Puller | Equipment | Sutter Instrument Company | ||
Microfil syringe needles | Equipment | World Precision Instruments | ||
Micromanipulator | Equipment | Siskiyou, Inc. | ||
Monitor | Equipment | Triview |