This video presents a procedure for intracranial cannula implantation in a brain tumor mouse model, to facilitate the administration of an immunotherapeutic agent. The delivery of glypican-2-specific chimeric antigen receptor T cells in the tumor microenvironment triggers T cell activation, resulting in tumor lysis and tumor regression.
Protocol
All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board. 1. Preparing the mouse for surgery Anesthetize the mouse in an induction chamber with isoflurane (2-4%) at an oxygen flow rate of 1 L/min until an adequate plane of anesthesia is reached (approximately 5 min). Weigh the mouse using a scale to the nearest 0.1 g and administer subcutaneous slow-release (SR) bupreno…
Representative Results
Figure 1: Guide cannula with projection dummy and treatment cannulas. (A) Guide cannula with 0.5 mm projection and 2 mm projection dummy cannulas in place. (B) Guide cannula with 0.5 mm projection and 2 mm projection treatment cannulas in place.
開示
The authors have nothing to disclose.
Materials
18 G needles
BD
511097
1 1/2 inch metal hub
Acrylic resin liquid
Lang Dental
B1323
Acrylic resin powder
Lang Dental
B1323
Alcohol wipes
BD
326895
Centrifuge 5240
Eppendorf
5420000040
Centrifuge
Cotton tipped swabs
Puritan
826-WC
Handle Width = 2.11 mm (0.083), Head Width = 1.27 mm (0.050), Handle Length = 147.62 mm (5.812), Overall Length = 152.4 mm (6), Head Length = 12.7 mm (0.500)
Drill bit holder
P1 Technologies
DH-1
Drill bit holder for D56-D70
Drill bit
P1 Technologies
D58
1.07 mm
Dummy cannula
P1 Technologies
C315DCS-5/SPC
Configuration: Small cap; Length: Cut 5.00 mm below pedestal; Projection: 0.50 mm
Flat tip screwdriver
P1 Technologies
SD-80
Screwdriver
Graefe forceps
Fine Science Tools
11051-10
Forceps
Guide cannula
P1 Technologies
C315GS-5/SPC
Configuration: 5.00 mm pedestal height; Length: Cut 5.00 mm below pedestal
Hemostatic cotton pellets with racemic epinephrine
Pascal
1151602
MOXI Z Mini automated cell counter Kit
Moxi
MXZ001
Cell counter
NOD scid gamma (NSG) mice
Jackson Laboratory
5557
6 to 12-week-old males and females
Pasteur pipet
VWR
14673-043
PKG tubing
P1 Technologies
C313CT
Diameter: 0.58 mm x 1.27 mm
Porcelain 12 well plate
Flinn Scientific
AP6064
Povidone iodine
Medline
MDS093943
Scalpel
World Precision Instrument
50-822-457
Disposable Scalpel, no.10, sterile, 10/box, Plastic Handle with 6" Ruler
Screws
P1 Technologies
0-80 X 3/32
2.4 mm
Stereotaxic Frame
David Kopf Instruments
940
Model 940 Small Animal Stereotaxic Instrument with Digital Display Console
Student fine scissors
Fine Science Tools
91460-12
Scissors
Treatment cannula
P1 Technologies
C315IS-5/SPC
33GA; Configuration: Standard internal; Length: Cut 5.00 mm below pedestal; Projection: 0.50 mm
Treatment syringes
Hamilton
87908
5 µL, Model 75 Cemented Needle Special (SN) Syringe, 75SN/22/0.5"/PT3