This protocol describes a sensitive, cell-based cytotoxicity assay. By enumerating the decrease in frequency of live target CD4+ T cells in the presence of an increasing number of effector CD8+ T cells, this assay allows for the direct assessment of cytolytic activity of antigen-specific CD8+ T cells.
Cytolytic activity of CD8+ T cells is rarely evaluated. We describe here a new cell-based assay to measure the capacity of antigen-specific CD8+ T cells to kill CD4+ T cells loaded with their cognate peptide. Target CD4+ T cells are divided into two populations, labeled with two different concentrations of CFSE. One population is pulsed with the peptide of interest (CFSE-low) while the other remains un-pulsed (CFSE-high). Pulsed and un-pulsed CD4+ T cells are mixed at an equal ratio and incubated with an increasing number of purified CD8+ T cells. The specific killing of autologous target CD4+ T cells is analyzed by flow cytometry after coculture with CD8+ T cells containing the antigen-specific effector CD8+ T cells detected by peptide/MHCI tetramer staining. The specific lysis of target CD4+ T cells measured at different effector versus target ratios, allows for the calculation of lytic units, LU30/106 cells. This simple and straightforward assay allows for the accurate measurement of the intrinsic capacity of CD8+ T cells to kill target CD4+ T cells.
Cytolytic activity is the major function of CD8+ T cells but is still rarely measured as assays used for this purpose are cumbersome and have been difficult to standardize. Accurate measurement of this function is of paramount importance when characterizing effector functions of CD8+ T cells, as no reliable predictors of effective cell-mediated cytotoxicity have been described yet1,2. Here, we propose a new functional assay to measure the cytotoxic activity of antigen-specific CD8+ T cells on target CD4+ T cells. Several approaches have been developed to provide alternatives to the gold standard, chromium release assay. We present here a cell-based assay that reveals the entire process of killing as it measures the death of live target cells. This method was derived from protocols of flow cytometry-based cytotoxic assays in vivo in mice4,5 and in vitro in humans6. In this protocol, the antigen-specific CD8+ T cells contained in the total CD8+ T cell population are used as effector cells and autologous CD4+ T cells are used as target cells. Effector CD8+ T cells of interest are enumerated using MHCI/peptide tetramers7. Death of target cells is calculated by the ratio between peptide loaded/nonloaded CD4+ T cells. We have previously shown that this method was reproducible, sensitive, specific and did not depend on the number of effector cells within the total CD8+ T cell population8. By enumerating both the number of effector and target cells in the coculture assay, the intrinsic capacity of CD8+ T cells to kill target cells can be calculated and expressed in lytic units9.
1. Preparation of Effector CD8+ T Cells
2. Preparation of Target CD4+ T Cells
3. Coculture
4. Flow Cytometry Staining and Acquisition
The schematic in Figure 1 summarizes the assay. Purified CD8+ T cells (effector cells) were resuspended in 450 µl of complete RPMI and serial dilutions were performed by adding 225 µl of CD8+ T cells to the next tube containing 225 µl of media (upper panel). Purified CD4+ T cells (target cells) were counted, split into two tubes and stained with two different concentrations of CFSE (high and low) as described in the protocol. CFSE-low CD4+ T cells were pulsed with the peptide of interest and CFSE-high CD4+ T cells remained unloaded as a control. CFSE-high and CSFE-low CD4+ T cells were resuspended at 2 x 105/ml and mixed at a ratio of 1:1 (lower panel). The mixed CD4+ T cells were seeded at 100 µl in each well. Three wells containing the mixed CD4+ T cells were used for triplicate of CD4+ T cells alone (wells in red). 100 µl of each CD8+ T cell dilution was added in duplicate to the remaining wells containing the mixed CD4+ T cells (wells in green). The killing of target cells was assessed by flow cytometry after 6 hr of coculture.
After incubation, cells were analyzed and gated as in Figure 2. The ratio of viable CFSE-high versus CFSE-low target cells, un-pulsed or peptide pulsed was analyzed from a small FSC-A/SSC-A gate. Live cells were gated on LIVE/DEAD negative. CD4+ T cells were plotted on CFSE in order to analyze the ratio CFSE-low versus CFSE-high cells. A larger FSC-A/SSC-A gate was then created to enumerate the total number of effector and target cells after 6 hr incubation, either dead or alive. Tetramer+ CD8+ T cells and CFSE-low CD4+ T cells were plotted in order to analyze the ratio effector versus target cells. The total number of effector CD8+ T cells was determined by gating on CD8+ and tetramer+ cells. The total number of target cells was determined by gating on CD4+ T cells CFSE-low and LIVE/DEAD positive and negative cells.
The results presented in Figure 3 show that the ratio of CFSE-low versus CFSE-high cells (target ratio) was 1:1 when CD4+ target cells were cultured in absence of effector cells. However, the ratio of CFSE-low versus CFSE-high cells was drastically decreased when CFSE-low cells pulsed with peptide were incubated with the total CD8+ T cell population containing antigen-specific CD8+ effector T cells. As the ratio decreased, the CFSE-low CD4+ pulsed target cells became LIVE/DEAD positive. The dilution of the effector cells (right panel) resulted in restoration of the CFSE ratio and decreased the number of LIVE/DEAD positive peptide-pulsed CFSE-low CD4+ target T cells.
For each well, the ratio between pulsed and un-pulsed live CD4+ target T cells (CFSE-low/CFSE-high) in the presence of different dilutions of effector CD8+ T cells was measured by calculating the ratio between antigen-pulsed CFSE-low CD4+ T cells and un-pulsed CFSE-high CD4+ T cells after 6 hr of culture with effector CD8+ T cells. The percentage of specific lysis for each well was calculated as follows: % specific lysis = 100 – ((CFSE low/CFSE high) in the presence of effector cells / mean of the three wells containing target cells alone in the absence of effector cells) x100. To determine the intrinsic cytolytic capacity of antigen-specific CD8+ T cells and compare results between donors, the cytolytic activity was expressed in lytic units as previously reported8. The effector versus target ratio (E/T) was measured by calculating the ratio between total tetramer+ CD8+ T cells and total CFSE-low CD4+ T cells for each well. The percentage of specific lysis was plotted in function of the E/T ratio in a log scale as illustrated in Figure 4. A linear regression was calculated from the plot and the equation of the trendline was used to calculate the lytic units LU30/106 cells (i.e. the number of CD8+ effectors T cells required to kill 30% of 106 target CD4+ T cells).
Figure 1. Schematic representation of the cytotoxic assay coculture. Purified CD8+ T cells were resuspended in 450 µl of complete RPMI and 5 serial dilutions were performed. Purified CD4+ T cells were counted, split into two tubes and stained with two concentrations of CFSE (0.02 µM CFSE-low and 0.2 µM CFSE-high). Only CFSE low CD4+ T cells were pulsed with 5 µg of specific peptide. After 45 min, both CFSE low and high CD4+ T cells were washed 2x, resuspended at 2 x 105/ml and mixed at a ratio of 1:1. 100 µl of mixed CD4+ were seeded in a 96-well plate in the presence or absence of 100 µl of each CD8+ T cell dilution for 6 hr. Click here to view larger image.
Figure 2. Gating strategy of the cytotoxic assay. From a smaller FSC-A/SSC-A gate, the ratio of CFSE-low versus CFSE-high cells was analyzed within the CD4+ LIVE/DEAD negative cells. From a larger FSC-A/SSC-A gate, effector cells were analyzed by gating on CD8+ T cells and tetramer+ cells. The number of target cells was analyzed by gating on CD4+ T cells, CFSE-low and LIVE/DEAD positive and negative cells. Click here to view larger image.
Figure 3. Representative results of FACS staining. CFSE-low/CFSE-high ratio (left panels), target cells (middle panels) and effector cells (right panels) in the different coculture conditions. Click here to view larger image.
Figure 4. Linear regression of specific lysis in function of the effector/target ratio. The equation of the trendline is used to calculate the lytic units LU30/106 cells. Click here to view larger image.
The assay described here allows for the quantification of the principal function of CD8+ T cells: the cytolytic activity. The accurate measurement of this function is of paramount importance when characterizing effector functions of CD8+ T cells, as previous studies reported discordance between this function and the cytokine secretion of antigen-specific CD8+ T cells10,11. Due to the short coculture incubation time (6 hr) and the use of autologous target cells, there is low rate of nonspecific killing of target cells. This assay is therefore highly specific and reliable. This assay can also be easily modified to analyze different cell subsets. The effector CD8+ T cells can be replaced by other cell types, such as CD4+ T cells as recently described in the in vivo killing assay12. The target CD4+ T cells can also be replaced by other cell types, as we previously described the use of autologous B cells as target cells8. In this system, the origin of the antigen can be replaced as well. For example, target cells could be infected with a virus instead of pulsed with peptides. This protocol provides an accurate method to quantify the cytolytic activity of antigen-specific CD8+ T cells. As this method is versatile and easy to perform, measuring the killing capacity of effector cells might be performed more often in the quantification of CD8+ T cell functions.
The authors have nothing to disclose.
This work was supported by the Office of Tourism, Trade, and Economic Development of Florida.
EasySep Human CD4+ T Cell Enrichment Kit | Stem Cell | 19052 |
EasySep Human CD8+ T Cell Enrichment Kit | Stem Cell | 19053 |
CellTrace CFSE Cell Proliferation Kit – For Flow Cytometry | Invitrogen | C34554 |
Far Red LIVE/DEAD fixable dead cell | Invitrogen | L10120 |
Alexa Fluor 700 Mouse Anti-Human CD3 | BD | 557943 |
Brilliant Violet 650 Anti-Human CD4 Antibody | Biolegend | 317435 |
PerCP anti-human CD8 Antibody | Biolegend | 344707 |
RPMI 1640 Medium 1x | VWR | 10-040-CV |
Penicillin-Streptomycin 100x Solution | Invitrogen | 15070063 |
Fetal Bovine Serum – Gold, Heat Inactivated | PAA | A15-252 |
96-well plates; Treated; U-bottom; with lid | BD Falcon | 353077 |
25 ml sterile polystyrene, individually wrapped reservoirs | USA Scientific | 2321-2230 |
96-well U-bottom, sterile 2 ml deep well plates | Thermo Scientific | 275743 |
Human IL-2 (v126), research grade | Miltenyi Biotec | 130-093-096 |
RoboSep Buffer, separation buffer | Stem cell | 20104 |
15 ml Polypropylene Conical Tube | BD Falcon | 352097 |
14 ml round bottom tube, polypropylene | BD Falcon | 352059 |
The Big Easy EasySep Magnet | Stem cell | 18001 |
PBS 1x | VWR | 21-040-CV |
96-well; V-bottom plate with lid | Fisher | 12-565-481 |
Formaldehyde solution, ACS reagent, 37 wt % in H2O | Sigma-Aldrich | 252549-500ML |
1.5 ml screw cap microtube, conical | Sarstedt | 72.692.005 |