We present a method of creating a thinned-skull cortical window (TSCW) in a mouse model for in vivo OCT imaging of the cerebral cortex.
Optical coherence tomography (OCT) is a biomedical imaging technique with high spatial-temporal resolution. With its minimally invasive approach OCT has been used extensively in ophthalmology, dermatology, and gastroenterology1-3. Using a thinned-skull cortical window (TSCW), we employ spectral-domain OCT (SD-OCT) modality as a tool to image the cortex in vivo. Commonly, an opened-skull has been used for neuro-imaging as it provides more versatility, however, a TSCW approach is less invasive and is an effective mean for long term imaging in neuropathology studies. Here, we present a method of creating a TSCW in a mouse model for in vivo OCT imaging of the cerebral cortex.
Since its introduction in the early 1990’s, OCT has been used extensively for biological imaging of tissue structure and function2. OCT generates cross-sectional images by measuring echo time delay of backscattered light4 by implementing low coherence light source with a fiber-optic Michelson interferometer2,4. SD-OCT, also known as Fourier domain OCT (FD-OCT), was first introduced in 19955 and offers a superior imaging modality compared with traditional time domain OCT (TD-OCT). In SD-OCT, the reference arm is kept stationary resulting in a high speed and ultra high resolution image acquisition6-9.
Presently, TSCW models have been used largely for in vivo brain imaging applications of two-photon microscopy in place of a traditional craniotomy. These TSCW have been used concurrently with a custom skull plate or a glass cover slip10-13 to provide additional imaging stability. In our studies, we have observed that accessories such as these are not necessary for OCT imaging when a TSCW is used. Therefore, the lack of a skull plate or glass cover slips allows for a wider range of imaging window size as they may interfere with the optical beam and alter OCT images.
A thinned-skull preparation has proven to be advantageous in imaging studies of the brain using two-photon microscopy10-13. In our experiments, we utilize a SD-OCT system to image the cortex in vivo through a TSCW. Our custom SD-OCT imaging setup contains a broadband, low-coherence light source consisting of two superluminescent diodes (SLD) centered at 1295 nm with a bandwidth of 97 nm resulting in an axial and lateral resolution of 8 μm and 20 μm, respectively14. With our optical imaging device, we envision that imaging through a TSCW has great potential in identifying and visualizing structures and functions in the optically dense brain tissue.
1. Surgical Preparation
2. Thinned-skull Cortical Window Preparation
3. Optical Coherence Tomography Imaging
After creating a thinned window over the cerebral cortex the vasculature should now be more visually prominent (Figure 1) and will allow for a deeper imaging depth (up to 1 mm). The right cortex is thinned to approximately 55 μm as compared to a normal skull measured at 140 μm (Figure 1) and provides greater optical clarity. Further thinning to 10-15 μm is possible11 however not necessary as the use of glass cover slips and skull plates are not implemented in our experiments (Figure 1 and 2). This particular method has allowed us to identify specific structures (cerebral cortex, corpus callosum) in our OCT cross-sectional images (Figure 3). Parasagittal OCT images of a normal skull (Figure 3A) versus a thinned skull (Figure 3B) are shown to compare the outcome of an OCT image with a successful TSCW. Additionally, a coronal cross-sectional OCT image is also obtained to facilitate in identifying midline structures (Figure 3C). The maximum signal intensity for Figure 3 is 45 dB above the noise floor. An intensity profile comparison of a non-thinned skull and a thinned skull reveals a greater signal intensity and depth penetration in a TSCW model (Figure 4).
Figure 1. TSCW in a mouse model. A 4 × 4 mm thinned skull window (denoted in the dotted square box) is created ~ 1 mm posterior and lateral to bregma over the right cerebral hemisphere using various dental burs. The right cortex (thinned to approximately 55 μm) is significantly more transparent than the non-thinned skull (left cortex, 140 μm) providing greater depth penetration for optical imaging using OCT. β = bregma, λ = lambda, SS = sagittal suture.
Figure 2. OCT imaging of TSCW in vivo. A mouse model with a thinned-skull is fixed in a stereotactic frame under the objective for OCT imaging in vivo.
Figure 3. OCT images of the cerebral cortex in vivo. (A) Parasagittal OCT image of the cortex under a normal skull. (B) Parasagittal OCT image of the cortex under a thinned skull. (C) Coronal OCT image of a thinned skull (left) and a normal skull (right). The structures of the brain are more visually apparent under a TSCW as compared to a normal skull. OCT images from were obtained from the same mouse in vivo with imaging size 5.5 mm × 2 mm with maximum signal intensity of 45 dB. β = bregma, CC = corpus callosum, SS = sagittal suture, scale bar = 1 mm.
Figure 4. Intensity profile comparisons of normal and thinned skull prep. TSCW permits increased signal intensity and depth penetration. The TSCW achieves an imaging depth of about 1 mm with sufficient SNR.
Imaging with OCT and a thinned-skull is a novel neuro-imaging technique that has only been recently investigated15, 16. In our experiments, we demonstrated the feasibility of SD-OCT imaging through a TSCW in a mouse model in vivo. From our results, the skull is thinned to approximately 55 μm and the penetration depth is obtained at approximately 1 mm with image resolution of 8 μm and 20 μm in the axial and lateral direction, respectively. In the signal intensity profile, OCT imaging through a TSCW increases the signal intensity and depth penetration as compared to a normal skull (Figure 4). In comparison, two-photon imaging with a TSCW at skull thickness of ~10-15 μm can reach imaging depths of 150-250 μm below pial surface10, 11, 13 with axial resolution at ~3 μm10 while a thinned skull of ~20 μm imaging depth can reach up to 300-400 μm within the cerebral cortex12. Overall, optical imaging with OCT proves to be a promising imaging modality, permitting a thicker TSCW during the thinning process while providing deeper depth penetration than mutiphoton microscopy.
Utilizing a thinned-skull is advantageous in optical imaging such as OCT15, 16 and two-photon microscopy10-13 as it provides little to no neuroinflammation as compared to a craniotomy if thinning is conducted successfully11, 12, 15, 16 ,. Employing a craniotomy for imaging may result in reactive microglia as well as upregulation of glial fibrillary acidic protein (GFAP) in reactive astrocytes after insults to the brain. However, imaging after adopting a thinned-skull technique reveals non-active microglia and weak GFAP immunostaining implying non-reactive astrocytes10. Through proper thinning of the skull, specific structures within the cerebral cortex, such as microglia morphology and cortical vasculature, can be distinguished11-13. Nevertheless, there are drawbacks of using a TSCW for optical imaging. If the skull is not thinned to the correct thickness or the skull has rough surfaces due to improper thinning depth penetration for imaging may be limited. Another downside for poor imaging depth may result from sub-dural hemorrhage due to vibrations of drilling. Bleeding underneath the dura is unavoidable and therefore cannot be used for OCT imaging. In cases such as these, a new animal model should be used for the experiment.
Identifying certain structures within the cortex using OCT through a TSCW can be helpful in tracking neurodegenerative diseases and in studying changes in brain function. Imaging blood flow can be achieved through Doppler OCT17, 18 as quantifying cerebral blood flow is paramount in monitoring the metabolic demands of the brain in studying stroke, Alzheimer’s disease18, or brain tumors17. Axonal and neuronal degeneration is also prominent in OCT images and can benefit studies of various brain disorders. By imaging the retinal nerve fiber layer (RNFL), which contains ganglion cell axons, mechanisms of neuro-degeneration, neuro-protection, and neuro-repair can be visualized not only in optical disorders but also in neurological diseases such as Parkinson’s19 and multiple sclerosis20, 21, the latter which has been explored in detail by measuring the macula21 and retinal layer thickness through OCT segmentation techniques20.
Neuro-imaging with OCT is not only restricted to imaging structures and functions of the brain. OCT can be advantageous in chronic in vivo imaging10, 11 as well as in stereotactic procedures such as electrophysiological and microinjection studies1, 3, 15-17. In neurosurgery, OCT can be used as a biopsy or guiding tool2 by allowing surgeons to view real-time feedback images of specific anatomical features within the brain17. With further developments, we believe our current combination of SD-OCT with a TSCW has the potential to improve a clinician’s ability to diagnosis neurological deficits when it is applied with other modalities such as an intracranial pressure (ICP) monitor22, magnetic resonance imaging (MRI), or computerized axial tomography (CAT)1.
The authors have nothing to disclose.
This work was supported by the UC Discovery Proof of Concept grant and by the NIH (R00 EB007241). The authors would also like to thank Jacqueline Hubbard for her assistance in this experiment.
Materials | Company | Catalogue number | Comments |
Ketamine | Phoenix Pharmaceuticals | 57319-542-02 | |
Xylazine | Akorn, Inc. | 139-236 | |
Artificial Tears Ointment | Rugby | 0536-6550-91 | |
Nair | Church & Dwight Co., Inc. | 4010130 | |
Sterile Alcohol Prep Pad | Kendall Healthcare | 6818 | |
Cotton Tipped Applicators | Fisherbrand | 23-400-115 | |
Betadine Solution Swabstick | Purdue Products | 67618-153-01 | |
Saline Solution, .9% | Phoenix Pharmaceuticals | 57319-555-08 | |
Stereotactic Frame | Stoelting | ||
High Speed Surgical Hand Drill | Foredom | 38,000 rpm | |
Carbide Round Bur | Stoelting | 0.75 mm | |
Dura-Green Stones | Shofu | Shank: HP Shape: BA1 |
|
CompoMaster Coarse & CompoMaster Polisher | Shofu | Shape: Mini-Pt. | |
SpaceDrapes | Braintree Scientific, Inc. |