Intravital fluorescence microscopy can be utilized to study leukocyte-endothelial interactions and capillary perfusion in real-time. This protocol describes methods to image and quantify these parameters in the pulmonary microcirculation using a vacuum-stabilized lung imaging system.
Intravital imaging of leukocyte-endothelial interactions offers valuable insights into immune-mediated disease in live animals. The study of acute lung injury (ALI)/acute respiratory distress syndrome (ARDS) and other respiratory pathologies in vivo is difficult due to the limited accessibility and inherent motion artifacts of the lungs. Nonetheless, various approaches have been developed to overcome these challenges. This protocol describes a method for intravital fluorescence microscopy to study real-time leukocyte-endothelial interactions in the pulmonary microcirculation in an experimental model of ALI. An in vivo lung imaging system and 3-D printed intravital microscopy platform are used to secure the anesthetized mouse and stabilize the lung while minimizing confounding lung injury. Following preparation, widefield fluorescence microscopy is used to study leukocyte adhesion, leukocyte rolling, and capillary function. While the protocol presented here focuses on imaging in an acute model of inflammatory lung disease, it may also be adapted to study other pathological and physiological processes in the lung.
Intravital microscopy (IVM) is a useful imaging tool for visualizing and studying various biophysical processes in vivo. The lung is highly challenging to image in vivo due to its enclosed location, the fragile nature of its tissue, and motion artifacts induced by respiration and heartbeat1,2. Various intravital microscopy (IVM) setups have been developed for real-time imaging of leukocyte-endothelial interactions in pulmonary microcirculation to overcome these challenges. Such approaches are based on surgically exposing and stabilizing the lung for imaging.
Animals are typically prepared for lung IVM by surgical procedures. First, animals are intubated and ventilated, which permits surgical excision of a thoracic window and subsequent interventions to stabilize the lung for imaging. One technique involves gluing the parenchyma onto a glass coverslip3, a procedure that risks significant physical trauma to the imaged tissue. More advanced is the utilization of a vacuum system to stabilize the lung under a glass window4. This setup facilitates loose adherence of the lung surface to the coverslip via a reversible vacuum spread over a large local area and expands the lung while still limiting the movement in x, y, and z dimensions4. The vacuum is applied evenly through a channel surrounding the imaging area of the setup and pulls the tissue into a shallow conical region facing the imaging-grade coverslip4. Through this viewing window, the lung microcirculation can be studied using various optical imaging modalities.
Lung IVM enables quantitative imaging of a multitude of microcirculatory parameters. These include measurements such as leukocyte track speed and length5, red blood cell flow velocity6 and oxygenation7, tumor metastases8, the distinction of immune cell subpopulations9,10,11, visualization of microparticles12, alveolar dynamics13,14, vascular permeability15, and capillary function16. The focus here is on leukocyte recruitment and capillary function. Initiation of leukocyte recruitment in the pulmonary microcirculation involves transient rolling interactions and firm adhesive interactions between leukocytes and endothelial cells, both of which are increased under inflammatory conditions16,17. Typically, rolling is quantified by the number of leukocytes that pass an operator-defined reference line, while adhesion is quantified by the number of leukocytes that are immobile on the endothelium16. Capillary function may also be affected in inflammatory states, often resulting in decreased perfusion. This can be attributed to several factors, including a reduction of red blood cell deformability18 and variegated expression of inducible NO synthase by endothelial cells resulting in pathological shunting19. Typically, the aggregate length of perfused capillaries per area is measured and reported as functional capillary density (FCD).
Studying leukocyte recruitment in the lungs in real-time requires labeling biological targets with fluorescent dyes or fluorescent-labeled antibodies20. Alternatively, various transgenic mouse strains such as lysozyme M-green fluorescent protein (LysM-GFP) mice can be utilized to image specific immune cell subsets such as neutrophils21,22. The fluorescent-labeled leukocytes can then be visualized using widefield fluorescence microscopy, confocal microscopy, or multiphoton microscopy. These techniques achieve contrast by utilizing specific excitation wavelengths and detecting emitted fluorescence while simultaneously blocking the detection of the excitation wavelength, thus highlighting the labeled object.
Existing research concerning the quantification of leukocyte rolling, adhesion, and functional capillary density in the murine lung has relied primarily on manual video analysis. This is made possible through open-source software such as Fiji6,23, proprietary software such as CapImage12, or custom-made image processing systems24. Conversely, various proprietary software platforms (e.g., NIS Element, Imaris, Volocity, MetaMorph) enable automated measurement of a wide array of other physiological parameters, including many of those previously mentioned here5,6,7,8,9,10,11,12,13,15.
Important observations have been made regarding the pathology of acute lung injury (ALI) and acute respiratory distress syndrome (ARDS) using lung IVM. ARDS is characterized by a host of pathophysiological processes in the lung, including pulmonary edema and alveolar damage caused by dysfunction of the endothelium and epithelial barrier25. Using a murine model, it has been found that sepsis-induced ALI is associated with significant detrimental changes in immune cell trafficking in the lung environment26. Neutrophils recruited to the capillaries of mice with sepsis-induced ALI were found to impede microcirculation, thereby increasing hypoxia in ALI26. Additionally, IVM has been used to gain insights into the underlying mechanism of repair following the onset of ARDS27. Lung IVM has also been a valuable tool in understanding pathophysiological changes in various obstructive lung diseases. For example, visualization of mucus transport in diseases such as cystic fibrosis (CF) and chronic obstructive pulmonary disease (COPD) has facilitated the study of novel and existing treatments for mucous clearance28. Leukocyte trafficking under these conditions has been analyzed as well17.
This protocol expands on the approach initially described by Lamm et al.29 to study leukocyte-endothelial interactions using conventional fluorescence microscopy. The described procedures employ an in vivo lung imaging system, which includes a 16.5 cm x 12.7 cm metal base, micromanipulator, and vacuum imaging window (Figure 1). The system is mounted in a 20 cm x 23.5 cm 3-D printed platform (Supplemental File 1) to provide secure attachment for the ventilator tubing and heating pad. This method offers reproducible and quantifiable imaging of murine pulmonary microcirculation in vivo. Important aspects of the surgical preparation as well as proper utilization of a vacuum-stabilized lung imaging system are explained in detail. Finally, an experimental model of ALI is used to provide representative imaging and analysis of altered leukocyte rolling, leukocyte adhesion, and capillary perfusion associated with inflammation. The use of this protocol should facilitate further important investigations into pathophysiological changes in pulmonary microcirculation during acute disease states.
All the procedures described here were performed with prior approval by the Dalhousie University Committee on Laboratory Animals (UCLA).
1. Preparation
2. Anesthesia
3. Intubation
4. Ventilation
5. Thoracotomy
6. Microscopy
7. Euthanasia and cleaning protocol
To illustrate results achievable through this protocol, acute lung injury (ALI) was induced 6 h prior to imaging using a model of intranasal bacterial lipopolysaccharide (LPS) instillation. Briefly, mice (n = 3) were anesthetized with isoflurane, and small droplets of LPS from Pseudomonas aeruginosa in sterile saline (10 mg/mL) were pipetted into the left naris at a dosage of 5 mg/kg. This was compared to naïve mice (n = 3; no intranasal administration).
Upon imaging, a successful surgical preparation is identifiable by several factors. The lung should be relatively stable with respiration causing cyclic frameshifts no greater than 25 µm. Alveoli should be clearly visible and may exhibit tidal distension/contraction. Excitation by blue light (450-490 nm wavelength) will permit visualization of blood flow directionality, and it may be possible to distinguish individual red blood cells (Supplemental Movie 1, Supplemental Movie 3, and Supplemental Movie 5). Leukocytes will be clearly identifiable upon excitation by green light (530-560 nm wavelength, Supplemental Movie 2, Supplemental Movie 4, and Supplemental Movie 6). After completion of imaging and removal of the suction window, there may be slight bruising of the lung surface, although not within the imaged area, as shown in Figure 3B.
Several technical challenges may interfere with experimental viability. Accumulation of blood on the lung surface will compromise vacuum stabilization and may even clog the channel. To avoid this, extreme caution should be exercised during each surgical step. Excessively high vacuum pressure may damage the lung and affect microcirculation. This may be identifiable by alveolar stasis or excessive bruising on the pulmonary surface (Figure 3C) and can be remedied by reducing pressure from the vacuum pump. As well, errors in intravenous fluorophore injection may lead to poor visualization of leukocyte trafficking and blood flow.
Following completion of the protocol, blinded manual analysis was performed using Fiji21 in a manner adapted from the previous literature28. Five venules, arterioles, and capillary regions-of-interest (ROIs) were analyzed from each animal. Leukocyte adhesion in venules and arterioles was defined as the number of cells that remain adhered to the vascular endothelium during 30 s of observation per area of endothelial surface. This is relayed in cells/mm2. Leukocyte adhesion in capillaries was defined as the number of cells within ROI that remain adhered to the vascular endothelium during 30 s of observation per total analyzed area. This is also relayed in cells/mm2. Leukocyte rolling was defined as twice the number of cells passing a reference point in the vessel during the 30 s observation period. Free-flowing leukocytes were excluded by comparing the speed of passage with that of red blood cell flow, and this is relayed in cells/min. To measure microcirculatory perfusion, FCD was defined as the sum of the lengths of red blood cell-perfused capillaries per observation area. This is relayed in cm/cm2. Each parameter is reported as a mean value for each animal.
A common trend of leukocyte recruitment was observed in pulmonary venules, with increased adhesion and rolling in LPS-treated mice versus naïve ones (Figures 4C,D). This trend was recapitulated by arteriolar leukocyte adhesion, although both levels of rolling and adhesion were highly variable in the naïve group (Figures 5C,D). Notably, LPS administration resulted in a substantial increase in leukocyte adhesion in pulmonary capillary ROIs (Figure 6C). LPS mice also demonstrated a reduced FCD versus naïve mice (Figure 7C). These effects within the pulmonary capillaries are consistent with previous literature identifying increases in immune cells per field of view and derangement of normal capillary perfusion following various inflammatory stimuli4,5,16.
Figure 1: Lung imaging system. Custom-order system includes (1) an anodized metal base, (2) imaging window, (3) vacuum inlet, (4) micromanipulator. Please click here to view a larger version of this figure.
Figure 2: Surgical preparation. (A) Mouse is secured to the IVM platform in the right lateral decubitus position. (B) Ribcage is exposed using blunt dissection to preserve hemodynamics. (C) Thoracotomy is performed to expose the left lung. Please click here to view a larger version of this figure.
Figure 3: Vacuum stabilization. (A) Application of vacuum imaging window stabilizes pulmonary surface. (B) Utilization of vacuum pressures below 75 mmHg minimizes damage to the lung, particularly within the imaged area. (C) Higher vacuum pressures may cause significant bruising. Please click here to view a larger version of this figure.
Figure 4: Leukocyte trafficking in pulmonary venules. Excitation of rhodamine 6G permits visualization of adherent and rolling leukocytes. Outlined areas represent analyzed portions of vascular endothelium as confirmed by excitation of FITC-albumin in (A) naïve and (B) LPS-treated mice. (C,D) Intranasal LPS administration impacts leukocyte rolling and adhesion in pulmonary venules. Values are given as mean ± SD. Please click here to view a larger version of this figure.
Figure 5: Leukocyte trafficking in pulmonary arterioles. Excitation of rhodamine 6G permits visualization of adherent and rolling leukocytes. Outlined areas represent analyzed portions of vascular endothelium as confirmed by excitation of FITC-albumin in (A) naïve and (B) LPS-treated mice. (C,D) Intranasal LPS administration impacts leukocyte rolling and adhesion in pulmonary arterioles. Values are given as mean ± SD. Please click here to view a larger version of this figure.
Figure 6: Adherent leukocytes in pulmonary capillaries. Excitation of rhodamine 6G permits visualization of leukocytes within ROIs in (A) naïve and (B) LPS-treated mice. (C) Intranasal LPS administration impacts leukocyte adhesion in LPS-treated mice. Values are given as mean ± SD. Please click here to view a larger version of this figure.
Figure 7: Pulmonary capillary function. Excitation of FITC-albumin permits visualization of capillary blood flow within ROIs in (A) naïve and (B) LPS-treated mice. (C) Intranasal LPS administration impacts FCD in pulmonary capillaries. Values are given as mean ± SD. Please click here to view a larger version of this figure.
Supplemental File: File for 3D-printable IVM platform. Please click here to download this File.
Supplemental Figure 1: Diagram of the vacuum system. Please click here to download this File.
Supplemental Movie 1: Sample video of blood flow in the pulmonary venule. The green arrow denotes the direction of the blood flow. Please click here to download this Movie.
Supplemental Movie 2: Sample video of leukocyte trafficking in the pulmonary venule. Red arrows denote adherent leukocytes within the vessel. Please click here to download this Movie.
Supplemental Movie 3: Sample video of blood flow in the pulmonary arteriole. The green arrow denotes the direction of the blood flow. Please click here to download this Movie.
Supplemental Movie 4: Sample video of leukocyte trafficking in pulmonary arteriole. Red arrows denote adherent leukocytes within a vessel. Please click here to download this Movie.
Supplemental Movie 5: Sample video of blood flow in pulmonary capillaries. Green arrows denote several well-visualized areas of red blood cell-perfused capillaries. Please click here to download this Movie.
Supplemental Movie 6: Sample video of leukocyte trafficking in pulmonary capillaries. Red arrows denote adherent leukocytes within the field of view. Please click here to download this Movie.
The protocol presented here requires practice and attention to a few critical steps. First, it is important to prepare the imaging window prior to initiating intubation and surgery. Use a minimal amount of vacuum grease to coat the outer ring of the imaging window, apply the cover glass, and test suction with a drop of distilled water. Preparing this in advance will prevent the exposed lung from drying out during the setup otherwise. While it is possible to flush with warm saline, doing so may risk damaging the fragile pulmonary tissue.
After intubation, while transferring the mouse to the IVM platform, the cannula may occasionally become displaced. To prevent this, consider tying the cannula to the mouse’s front teeth or suturing it to the skin around its mouth. If using pressure-controlled ventilation, the tidal volume should be carefully monitored throughout the procedure. It should remain steady at approximately 0.20 mL, as significantly lower values (e.g., ~0.10 mL) may indicate single lung ventilation. If this occurs, slightly retracting the endotracheal cannula may resolve the issue. The use of inhalant anesthesia (isoflurane) facilitates control of anesthetic depth while the mouse is ventilated. Other means of anesthesia (e.g., intravenous ketamine/xylazine10,11) have been employed by other laboratories, and each carry their respective advantages and drawbacks.
During the surgery, blunt dissection is employed to minimize the risk of severing blood vessels. This is of particular importance when dissecting the thick and heavily vascularized adipose tissue near the shoulder. Resection of the ribcage requires both speed and accuracy. The heat from the cauterizer is intense enough to burn the lung if used excessively. When resecting the ribcage, there should be empty space between the lung and the chest wall. If the lung adheres to the chest wall, lightly pressing down on the outside of the rib cage will encourage adhesion to the underlying parietal pleura. Alternatively, use a blunt needle to inject a small amount of warm saline between the lung and the ribcage to facilitate release. Positioning the window arm at the 3 o’clock position is advised to avoid unwanted pressure on the ribs during imaging (Figure 3A). It will also leave more clearance between the micromanipulator and the microscope objective, allowing easier access for manipulations. When lowering the imaging window, it is critical to target the central region of the lung as contact with the edge will result in an inadequate seal and excessive motion artifact during imaging. Also, multiple attempts to lower the window can damage the lung. Likewise, cycles of detachment and re-stabilization will contribute to lung injury and may compromise experimental accuracy. When performed correctly, however, the preparation presented here is stable enough to enable high-resolution intravital imaging with a 20x objective.
A rigorous cleaning protocol is necessary to prevent contamination and blockage of the vacuum channel within the imaging window. Using a 30 G needle immediately following experiments to repeatedly flush with distilled water is effective for removing most contaminants. This is followed by a flush with concentrated ethanol and a final flush with distilled water before reattaching to the vacuum line to remove moisture. Using acetone or strong detergents may be adequate to resolve serious blockages, should they occur.
Notably, this protocol employs a higher readout of vacuum pressure versus some other reported methods4,11, and this may raise concerns of damage to lung tissue. An important distinction, however, is that the digital gauge used here measures pressure only at the vacuum pump. This pressure is delivered through narrow tubing and the extremely narrow channel of the imaging window itself prior to distribution over a larger surface area of the lung. As such, no evidence of damage to the imaged region was observed in these experiments following intravital sessions. Furthermore, imaged alveoli exhibited tidal distension and contraction, indicating that this physiological phenomenon was not significantly disrupted.
Despite the increasing popularity of lung IVM as a tool for studying disease in vivo, there are limitations to this technique. First, the invasive and terminal nature of the surgery induces a non-negligible effect on the mouse’s physiological state and limits the procedure to a single imaging session. However, it should be noted that several longitudinal lung IVM approaches have been developed30. Second, the use of mechanical ventilation may induce a degree of ventilator-associated lung injury (VALI)31, although this is limited by the short duration of the procedure. Third, contact between the visceral pleura and glass coverslip and the application of vacuum pressure may result in altered microvascular blood flow. Finally, perhaps the most significant limitation of this approach is that imaging is restricted to subpleural alveoli in non-dependent pulmonary regions, which are not representative of the entire lung32.
In summary, this protocol can be used to study leukocyte-endothelial interactions in the pulmonary microvasculature using intravital fluorescence microscopy. While these experiments employ endotoxin-induced lung injury, an acute model which was selected based on previous research, this protocol may also be adapted to study other pathological and physiological processes in the lung. Furthermore, the lung imaging system employed here is applicable to a range of microscopy approaches, and the imaging window is large enough to accommodate high numerical aperture oil-immersion objectives. Thus, the described procedures should facilitate further research into the impact of various disease states on pulmonary microcirculation.
The authors have nothing to disclose.
The authors would like to thank Dr. Pina Colarusso, who provided significant expertise in the editing and revising of this manuscript.
1 mL BD Luer Slip Tip Syringe sterile, single use | Becton, Dickinson and Company | 309659 | 1 mL syringe |
ADSON Dressing Forceps, Tip width 0.6 mm, teeth length 11.5 mm, 12 cm | RWD Life Science Co. | F12002-12 | Blunt forceps |
Albumin-Fluorescein Isothiocyanate | Sigma-Aldrich | A9771-1G | FITC-albumin |
Alcohol Swab Isopropyl Alcohol 70% v/v | Canadian Custom Packaging Company | 80002455 | Alcohol wipe |
AVDC110 Advanced Digital Video Converter | Canopus | 00631069602029 | Digital video converter |
B/W – CCD – Camera | Horn Imaging | BC-71 | Camera |
Bovie Deluxe High Temperature Cautery Kit | Fine Science Tools | 18010-00 | Cauterizer |
C57BL/6 Mice | Charles River Laboratories International | C57BL/6NCrl | C57BL/6 Mice |
Cotton Tipped Applicators | Puritan | 806-WC | Cotton applicator |
CS-8R 8mm Round Glass Coverslip | Warner Instruments | 64-0701 | Glass coverslip |
Digital Pressure Gauge | ITM Instruments Inc. | DG2551L0NAM02L0IM&V | Digital Pressure Gauge |
Dr Mom Slimline Stainless LED Otoscope | Dr. Mom Otoscopes | 1001 | Otoscope |
Ethyl Alchohol 95% Vol | Commercial Alcohols | P016EA95 | 95% ethanol |
Fine Scissors – Martensitic Stainless Steel | Fine Science Tools | 14094-11 | Scissors |
Fisherbrand Colored Labeling Tape | Fisher Scientific | 1590110 | Labeling tape |
Gast DOA-P704-AA High-Capacity Vacuum Pump | Cole-Parmer Canada Company | ZA-07061-40 | Vacuum pump |
Hartman Hemostats | Fine Science Tools | 13003-10 | Hemostatic forceps |
High Vacuum Grease | Dow Corning | DC976VF | Vacuum grease |
Isoflurane USP | Fresenius Kabi | CP0406V2 | Isoflurane |
LIDOcaine HCl Injection 1% 50 mg/5 mL | Teligent Canada | 0121AD01 | Lidocaine HCl 1% |
Lung SurgiBoard | Luxidea, Inc. | IMCH-0001 | Designed for intravital microscopy of the lung |
Mineral Oil | Teva Canada | 00485802 | Mineral oil |
Mouse Endotracheal Intubation Kit | Kent Scientific Corporation | ETI-MSE | Intubation stand, anesthesia mask, 20 G endotracheal cannula, fibre optic cable |
MST49 Fluorescence Microscope | Leica Microsystems | 10 450 022 | Fluorescence Microscope |
N Plan L 20x/0.40 Long Working Distance Microscope Objective | Leica Microsystems | 566035 | 20x objective |
Non-Woven Sponges 2" x 2" | AMD-Ritmed | A2101-CH | Gauze |
Optixcare Eye Lube Plus | Aventix | 5914322 | Tear gel |
Original Prusa i3 MK3S+ 3D Printer | Prusa Research | PRI-MK3S-KIT-ORG-PEI | 3D printer |
Oxygen, Compressed | Linde Canada Inc. | Oxygen | |
PrecisionGlide Needle 30 G x 1/2 (0.3 mm x 13 mm) | Becton, Dickinson and Company | 305106 | 30 G needle |
Pyrex 5340-2L 5340 Filtering Flasks, 2000 mL | Cole-Parmer Canada Company | 5340-2L | Vacuum flask |
Rhodamine 6 G | Sigma-Aldrich | 252433 | Rhodamine 6G |
Secure Soft Cloth Medical Tape – 3" | Primed | PM5-630709 | Cloth tape |
Silastic Medical Grade Tubing .040 in. ID x .085 in. OD | Dow Corning | 602-205 | 1.0 mm I.D. polyethylene tubing |
Somnosuite Low-Flow Anesthesia System | Kent Scientific Corporation | SS-01, SS-04-module | Small rodent ventilator, Low-flow anesthesia system, Heating pad, Rectal temperature probe, Pulse oximeter |
Tissue Forceps, 12.5cm long, Curved, 1 x 2 Teeth | World Precision Instruments | 501216 | Toothed forceps |
Transpore Medical Tape, 1527-1, 1 in x 10 yd (2.5 cm x 9.1 m) | 3M | 7000002795 | Medical tape |
Tubing,Clear,3/8 in Inside Dia. | Grainger Canada | USSZUSA-HT3314 | 1.0 cm I.D. polyethylene tubing |
Whatman 6720-5002 50 mm In-Line Filters, PTFE, 0.2 µm | Cole-Parmer Canada Company | 6720-5002 | Inline 0.2µm filter |