Summary

대뇌 혈류와의 광 산란 특성을 동시에 평가<em> 생체</em> 다중 스펙트럼 확산 반사 이미징을 이용한 쥐 뇌

Published: May 07, 2017
doi:

Summary

뇌 혈류 역학 및 생체 내 쥐의 뇌 조직의 산란 특성의 동시 평가는 종래의 멀티 스펙트럼 확산 반사율 촬상 시스템을 이용하여 설명된다.

Abstract

The simultaneous evaluation of cerebral hemodynamics and the light scattering properties of in vivo rat brain tissue is demonstrated using a conventional multispectral diffuse reflectance imaging system. This system is constructed from a broadband white light source, a motorized filter wheel with a set of narrowband interference filters, a light guide, a collecting lens, a video zoom lens, and a monochromatic charged-coupled device (CCD) camera. An ellipsoidal cranial window is made in the skull bone of a rat under isoflurane anesthesia to capture in vivo multispectral diffuse reflectance images of the cortical surface. Regulation of the fraction of inspired oxygen using a gas mixture device enables the induction of different respiratory states such as normoxia, hyperoxia, and anoxia. A Monte Carlo simulation-based multiple regression analysis for the measured multispectral diffuse reflectance images at nine wavelengths (500, 520, 540, 560, 570, 580, 600, 730, and 760 nm) is then performed to visualize the two-dimensional maps of hemodynamics and the light scattering properties of the in vivo rat brain.

Introduction

멀티 스펙트럼 확산 반사율 영상은 피질 조직에서 고유의 광 신호 (손실이 최소화)의 공간지도를 획득하기위한 가장 일반적인 방법이다. 형태 학적 변화에 의해 유발 된 광 산란 특성의 광 흡수 변화 의한 피질 혈류 역학에 대한 산란 성질, 감소 또는 미토콘드리아 내의 사이토 크롬의 산화에 따라 흡수 편차 및 변형 : 손실이 최소화 주로 세 현상에 기인하는 생체의 뇌에서 관찰 1.

근적외선 (NIR) 분광 범위 (VIS)에 보이는 빛을 효과적으로 흡수 및 생체 조직에 의해 산란된다. 생체의 뇌의 확산 반사율 스펙트럼은 흡수 및 산란 스펙트럼을 특징으로한다. 감소 된 스 캐터링 계수는 단조로운 산란 스펙트럼 전시에 VIS 투 NIR 파장 범위의 결과 뇌 조직들긴 파장에서 더 작은 크기를 보내고. 감소 된 산란 스펙트럼 계수 μ는 S '(λ)는 s의 μ로서 멱 함수 (2), (3)의 형태로 근사 할 수있는'(λ)는 λ × -b =. 산란 파워는 조직 B (2, 3) 살아있는 생물에서 산란의 크기에 관련된다. 조직 및 대뇌 피질의 생체 조직의 생존을 감소 형태 학적 변화는 생물학적 산란 4, 5, 6, 7, 8, 9의 크기에 영향을 미칠 수있다.

멀티 스펙트럼 확산 반사율 촬상 용 광학 시스템을 용이 백열 리로 구성 될 수있다GHT 원본, 간단한 광학 구성 요소 및 단색 충전 결합 소자 (CCD). 따라서, 다양한 알고리즘과 멀티 스펙트럼 확산 반사율 촬상 광학 시스템은 피질 혈류 역학 및 / 또는 티슈 형태 10, 11, 12, 13, 14, 15, 16, 17, 18을 평가하기 위해 사용되었다.

본 문서에 기재된 방법은 혈류 역학과 종래의 멀티 스펙트럼 확산 반사율 이미징 시스템을 사용하여 생체 내에서 래트 뇌 조직의 산란 특성 모두를 시각화하는데 사용된다. 대안 기술을 통해이 방법의 장점은 대뇌 혈류 역학과 대뇌 피질의 조직 모두의 시공간적 변화를 평가 할 수있는 기능입니다형태뿐만 아니라 다양한 뇌 기능 장애의 동물 모델에의 적용. 따라서, 방법은 외상성 뇌 손상, 간질 발작, 뇌졸중, 허혈의 조사에 적합합니다.

Protocol

동물 관리, 준비, 실험 프로토콜은 도쿄 농공 대학의 동물 연구위원회에 의해 승인되었다. 이 방법의 경우, 래트는 음식과 물을 사용할 수의와, 제어 된 환경 (24 ° C, 12 시간 광 / 암주기)에 수용된다. 광파 멀티 스펙트럼 확산 반사율 이미징 시스템의 1. 건설 산의 중심 파장 협 아홉 광학 간섭 필터 500, 520, 540, 560, 570, 580, 600, 730, 및 전동 필터 휠의 필터 구…

Representative Results

생체 래트 뇌로부터 취득한 확산 반사율의 대표적인 분광 화상 500, 520, 540, 560, 570에서도 3 이미지 표시되었으며 580 명확 대뇌 피질에서 혈관의 밀도 네트워크 시각화 nm의. 혈관 (600), (730)에서 이미지에 주변 조직 관찰, 및 760 nm의 사이의 콘트라스트의 저하는 이상과 NIR 파장의 광에 의한 헤모글로빈의 낮은 흡수를 반영한다. <p class="jove_content" fo:keep-to…

Discussion

이 프로토콜에서 가장 중요한 단계는 두개골 창을 만들 수있는 얇아 두개골 지역의 제거이다; 이 예기치 않은 출혈을 방지하기 위해주의 깊게 수행해야합니다. 이 단계는 높은 정밀도로 반사 이미지를 확산 다중 분광 높은 품질을 얻는 것이 중요하다. 실체 현미경의 사용은 수술 가능한 경우에 권장됩니다. 젤라틴 스폰지의 작은 조각 지혈하는 데 유용합니다.

이 문서에서 ?…

Divulgaciones

The authors have nothing to disclose.

Acknowledgements

Part of this work was supported by a Grant-in-Aid for Scientific Research (C) from the Japanese Society for the Promotion of Science (25350520, 22500401, 15K06105) and the US-ARMY ITC-PAC Research and Development Project (FA5209-15-P-0175).

Materials

150-W halogen-lamp light source Hayashi Watch Works Co., Ltd, Tokyo, Japan LA-150SAE
Light guide Hayashi Watch Works Co., Ltd, Tokyo, Japan LGC1-5L1000
Collecting lens Hayashi Watch Works Co., Ltd, Tokyo, Japan SH-F16
Interference filters l@500nm Edmund Optics Japan Ltd, Tokyo, Japan #65088
Interference filters l@520nm Edmund Optics Japan Ltd, Tokyo, Japan #65093
Interference filters l@540nm Edmund Optics Japan Ltd, Tokyo, Japan #65096
Interference filters l@560nm Edmund Optics Japan Ltd, Tokyo, Japan #67766
Interference filters l@570nm Edmund Optics Japan Ltd, Tokyo, Japan #67767
Interference filters l@580nm Edmund Optics Japan Ltd, Tokyo, Japan #65646
Interference filters l@600nm Edmund Optics Japan Ltd, Tokyo, Japan #65102
Interference filters l@730nm Edmund Optics Japan Ltd, Tokyo, Japan #65115
Interference filters l@760nm Edmund Optics Japan Ltd, Tokyo, Japan #67777
Motorized filter wheel  Andover Corporation, NH, USA FW-MOT-12.5
16-bit cooled CCD camera Bitran, Japan BS-40
Video zoom lens Edmund Optics Japan Ltd, Tokyo, Japan VZMTM300i
Spectralon white standard with 99% diffuse reflectance Labsphere Incorporated, North Sutton, NH, USA SRS-99-020

Referencias

  1. Bonhoeffer, T., Grinvald, A., Toga, A. W., Mazziotta, J. C. Optical Imaging based on intrinsic signals: the methodology. Brain mapping; the methods. , 55-97 (1996).
  2. Mourant, J. R., et al. Mechanisms of light scattering from biological cells relevant to noninvasive optical-tissue diagnostics. Appl. Opt. 37 (16), 3586-3593 (1998).
  3. Abookasis, D., et al. Imaging cortical absorption, scattering, and hemodynamic response during ischemic stroke using spatially modulated near-infrared illumination. J. Biomed. Opt. 14 (2), 024033 (2009).
  4. Lipton, P. Ischemic cell death in brain neuron. Physiol. Rev. 79 (4), 1432-1568 (1999).
  5. Jarvis, C. R., Anderson, T. R., Andrew, R. D. Anoxic depolarization mediates acute damage independent of glutamate in neocortical brain slices. Cereb. Cortex. 11 (3), 249-259 (2001).
  6. Joshi, I., Andrew, R. D. Imaging anoxic depolarization during ischemia-like conditions in the mouse hemi-brain slice. J. Neurophysiol. 85 (1), 414-424 (2001).
  7. Polischuk, T. M., Jarvis, C. R., Andrew, R. D. Intrinsic optical signaling denoting neuronal damage in response to acute excitotoxic insult in the hippocampal slice. Neurobiol. Dis. 4 (6), 423-437 (1998).
  8. Jarvis, C. R., Lilge, L., Vipond, G. J., Andrew, R. D. Interpretation of intrinsic optical signals and calcein fluorescence during acute excitotoxic insult in the hippocampal slice. NeuroImage. 10 (4), 357-372 (1999).
  9. Obeidat, A. S., Jarvis, C. R., Andrew, R. D. Glutamate does not mediate acute neuronal damage after spreading depression induced by O2/glucose deprivation in the hippocampal slice. J. Cereb. Blood Flow Metab. 20 (2), 412-422 (2000).
  10. Dunn, A. K., Devor, A., Dale, A. M., Boas, D. A. Spatial extent of oxygen metabolism and hemodynamic changes during functional activation of the rat somatosensory cortex. Neuroimage. 27 (2), 279-290 (2005).
  11. Jones, M., Berwick, J., Johnston, D., Mayhew, J. Concurrent optical imaging spectroscopy and laser-Doppler flowmetry: the relationship between blood flow, oxygenation, and volume in rodent barrel cortex. Neuroimage. 13 (6), 1002-1015 (2001).
  12. Jones, M., Berwick, J., Mayhew, J. Changes in blood flow, oxygenation, and volume following extended stimulation of rodent barrel cortex. Neuroimage. 15 (3), 474-487 (2002).
  13. Zhou, C., et al. Diffuse optical correlation tomography of cerebral blood flow during cortical spreading depression in rat brain. Opt. Express. 14 (3), 1125-1144 (2006).
  14. Bouchard, M. B., Chen, B. R., Burgess, S. A., Hillman, E. M. C. Ultra-fast multispectral optical imaging of cortical oxygenation, blood flow, and intracellular calcium dynamics. Opt. Express. 17 (18), 15670-15678 (2009).
  15. Jones, P. B., et al. Simultaneous multispectral reflectance imaging and laser speckle flowmetry of cerebral blood flow and oxygen metabolism in focal cerebral ischemia. J. Biomed. Opt. 13 (4), 044007 (2008).
  16. Kawauchi, S., et al. Diffuse light reflectance signals as potential indicators of loss of viability in brain tissue due to hypoxia: charge-coupled-device-based imaging and fiber-based measurement. J. Biomed. Opt. 18 (1), 015003 (2013).
  17. Yoshida, K., et al. Multispectral imaging of absorption and scattering properties of in vivo exposed rat brain using a digital red-green-blue camera. J. Biomed. Opt. 20 (5), 051026 (2015).
  18. Nishidate, I., et al. Evaluation of Cerebral Hemodynamics and Tissue Morphology of In Vivo Rat Brain Using Spectral Diffuse Reflectance Imaging. Appl. Spectrosc. , (2016).
  19. Wang, L. -. H., Jacques, S. L., Zheng, L. -. Q. MCML-Monte Carlo modeling of photon transport in multi-layered tissues. Comput. Methods Programs Biomed. 47 (2), 131-146 (1995).
  20. Tsytsarev, V., Premachandra, K., Takeshita, D., Bahar, S. Imaging cortical electrical stimulation in vivo: Fast intrinsic optical signal versus voltage-sensitive dyes. Opt. Lett. 33 (9), 1032-1034 (2008).
  21. Arnold, T., Biasio, M. D., Leitner, R. Hyper-spectral video endoscope for intra-surgery tissue classification using auto-fluorescence and reflectance spectroscopy. Proc. SPIE. 8087, 808711 (2011).
  22. Basiri, A., et al. Use of a multi-spectral camera in the characterization of skin wounds. Opt. Express. 18 (4), 3244-3257 (2010).
  23. Nishidate, I., Maeda, T., Niizeki, K., Aizu, Y. Estimation of melanin and hemoglobin using spectral reflectance images reconstructed from a digital RGB image by the Wiener estimation method. Sensors. 13 (6), 7902-7915 (2013).

Play Video

Citar este artículo
Nishidate, I., Mustari, A., Kawauchi, S., Sato, S., Sato, M. Simultaneous Evaluation of Cerebral Hemodynamics and Light Scattering Properties of the In Vivo Rat Brain Using Multispectral Diffuse Reflectance Imaging. J. Vis. Exp. (123), e55399, doi:10.3791/55399 (2017).

View Video