The monocyte monolayer assay (MMA) is an in vitro assay that utilizes isolated primary monocytes obtained from mammalian peripheral whole blood to evaluate Fcγ receptor (FcγR)-mediated phagocytosis.
Although originally developed for predicting transfusion outcomes of serologically incompatible blood, the monocyte monolayer assay (MMA) is a highly versatile in vitro assay that can be modified to examine different aspects of antibody and Fcγ receptor (FcγR)-mediated phagocytosis in both research and clinical settings. The assay utilizes adherent monocytes from peripheral blood mononuclear cells isolated from mammalian whole blood. MMA has been described for use in both human and murine investigations. These monocytes express FcγRs (e.g., FcγRI, FcγRIIA, FcγRIIB, and FcγRIIIA) that are involved in immune responses. The MMA exploits the mechanism of FcγR-mediated interactions, phagocytosis in particular, where antibody-sensitized red blood cells (RBCs) adhere to and/or activate FcγRs and are subsequently phagocytosed by the monocytes. In vivo, primarily tissue macrophages found in the spleen and liver carry out FcγR-mediated phagocytosis of antibody-opsonized RBCs, causing extravascular hemolysis. By evaluating the level of phagocytosis using the MMA, different aspects of the in vivo FcγR-mediated process can be investigated. Some applications of the MMA include predicting the clinical relevance of allo- or autoantibodies in a transfusion setting, assessing candidate drugs that promote or inhibit phagocytosis, and combining the assay with fluorescent microscopy or traditional Western immunoblotting to investigate the downstream signaling effects of FcγR-engaging drugs or antibodies. Some limitations include the laboriousness of this technique, which takes a full day from start to finish, and the requirement of research ethics approval in order to work with mammalian blood. However, with diligence and adequate training, the MMA results can be obtained within a 24-h turnover time.
The monocyte monolayer assay (MMA) is an in vitro assay originally developed to better predict blood transfusion outcomes in patients with auto- or alloantibodies to red blood cells (RBCs)1-5. By assessing the effect of anti-RBC antibodies in mediating Fcγ receptor (FcγR)-mediated phagocytosis using this in vitro assay, it is possible to predict the clinical outcome in vivo. Indeed, the MMA has been used successfully to avoid immune destruction of antibody-bound RBCs, despite the transfusion of serologically incompatible blood5. The typical pre-transfusion procedure for compatibility testing, also termed crossmatching, involves serological methods that include typing the patient’s blood for ABO and Rh antigens and screening for the presence of anti-RBC antibodies in the patient6. Blood matched for ABO/Rh is selected, and if antibodies are present, an attempt to identify them is made so that blood for transfusion can be further selected to avoid these antigens. An ideal crossmatch result occurs when all donor blood is serologically compatible with the patient’s blood, which reduces the risk of post-transfusion hemolysis7. However, this system falls short for the small group of patients who have become alloimmunized upon repeated transfusion or pregnancy. These patients produce alloantibodies against specific RBC antigens. Some produce antibodies to antigens of very high frequency in the general population, and thus become progressively more difficult to crossmatch8,9. Adding to the complexity, not all alloantibodies are clinically significant; in other words, the binding of an alloantibody to RBCs detected by a serology test does not necessarily result in hemolysis when antigen-positive, incompatible blood is transfused. The MMA was originally developed to assess the potential clinical significance of serologically incompatible blood in a transfusion setting1-5.
Since extravascular hemolysis of antibody-bound RBCs is known to be mediated by the mononuclear phagocyte system, primary monocytes/macrophages are utilized in the development of diagnostic assays. The first assay to study the interaction of monocytes, RBCs, and antibodies was published in 1975, but the sub-optimal conditions used led only to rosette formation (the binding of RBCs to the periphery of the monocyte), and no phagocytosis was observed10. Significant modifications to the assay were made by several groups, leading to an assay for which the level of phagocytosis of alloantibody-bound RBCs could be correlated to the clinical outcome of hemolysis1-5. Recently, the optimal storage conditions of clinical samples and further optimization of assay conditions were examined to enhance the utility of a clinical MMA crossmatch using autologous patient samples11.
Three other diagnostic techniques have been employed in addition to the MMA in predicting transfusion outcomes: the 51Cr release test, the rosette test, and the chemiluminescence test (CLT). In the 51Cr release test, the patient is injected with 51Cr-labeled donor RBCs, and the half-life of the labeled RBCs is monitored and is predictive of post-transfusion survival or clearance12,13. As this method uses radioactive materials, it is rarely performed anymore. The rosette test involves mixing and incubating monocytes with RBCs and quantifying the level of rosette formation (with no phagocytosis)14. The clinical significance of antibodies in vivo involves active phagocytosis by macrophages found in the spleen and/or the liver; thus, this method does not provide a relevant readout of phagocytosis. The CLT uses luminol to monitor the oxidative burst during monocyte phagocytosis of RBC, since luminol fluoresces blue when oxidized in the phagosome15. This method is good, but contamination by neutrophils can confound the readout. Parallel comparisons have been made to evaluate the sensitivity, practicality, and reproducibility of the four available methods, and both the CLT and MMA were ranked superior16. However, the CLT has been mainly utilized in assessing hemolytic disease of the fetus and newborn (HDFN), and the assay’s optimal pH of 8.0 might compromise the level of phagocytosis11.
In addition to its diagnostic and clinical utility, the MMA has been modified for other research purposes. Indeed, the MMA can not only serve as a functional assay to address discrepancies between serology and biology, it has also been used to retrospectively investigate the cause of hemolysis after intravenous immunoglobulin (IVIG) therapy17. It has also been used to examine the structure-function of chemical inhibitors of FcγR-mediated phagocytosis18-20 and to study the downstream signaling of FcγR-mediated phagocytosis21. In our laboratory, in addition to using a human MMA, we are developing a murine MMA using primary mouse peripheral blood mononuclear cells (PBMCs) and autologous RBCs. The rationale is to screen antibodies that can induce FcγR-mediated phagocytosis as an intermediate to developing an in vivo autoimmune hemolytic anemia (AIHA) mouse model (unpublished data). The various modifications focus on different aspects of the IgG antibody and FcγR interaction that induce phagocytosis.
O MMA é uma técnica trabalhosa que requer experiência tanto em cultura de tecidos e microscopia. Há vários passos críticos para garantir o sucesso: 1) geração da monocamada de monócitos; 2) opsonização dos glóbulos vermelhos, e 3) quantificação manual. A monocamada de monócitos não adere muito fortemente ao slide câmara, de modo que o pH fisiológico deve ser mantida durante todo o ensaio de 11 e um número adequado de PBMC deve ser semeadas. pipetagem vigorosa, a qual poderia perturbar as células aderidas, devem ser evitados. Uma abordagem é sempre remover e adicionar soluções a partir do mesmo canto da câmara, e para assegurar que o movimento é lento e constante. Do mesmo modo, durante o último passo de lavagem para remover o excesso de glóbulos vermelhos, o movimento deve ser lento e constante. Isto garante um mínimo de perturbações para a monocamada enquanto ainda remover a maioria dos GVs fagocitados-un. lavagem inadequada irá conduzir a uma elevada interferência de fundo dos GVs contaminantes, o que torna o manual quantification difícil. Em segundo lugar, os R 2 R 2 hemácias deve ser suficientemente opsonizado para se obter um índice médio de 80-120 fagocítica para o controlo fagocitose. Esta gama fagocítica desejado estabelece um equilíbrio entre a facilidade de contagem (por exemplo, monócitos com mais de 5 fagocitados GVs são difíceis de quantificar com precisão) e manutenção de uma quantidade adequada de fagocitose para análise estatística. O grau de opsonização pode ser confirmada por um IAT, e é necessária uma leitura entre 3+ a 4+. O R 2 R 2 hemácias deve ser descartado quando não há excesso de lise durante a lavagem, em que o sobrenadante passa a vermelho escuro, ou quando ocorre uma diminuição significativa na fagocitose é observado em experiências devido ao envelhecimento das células em armazenamento. Por último, a quantificação manual usando o microscópio pode ser complicado, especialmente quando se compara contagens entre o pessoal de laboratório e entre experimentos. Ao examinar o mesmo campo em cada poço, ou simplesmente pela contagem mais células, Uma contagem mais consistente pode ser obtido. formação lado-a-lado com um técnico experiente e a utilização de um conjunto de lâminas de formação designada é recomendado.
Uma grande crítica do MMA é a subjetividade da etapa de quantificação manual. No entanto, com formação adequada, a consistência pode ser obtido através de diferentes contadores. Outra limitação é a diferenças intrínsecas doador-a-doador em monócitos capacidades fagocíticas e em R 2 R níveis de expressão do antigénio de superfície 2, que é uma fonte de variação dos dados quando se lida com amostras humanas.
Outras técnicas alternativas estão disponíveis para examinar a fagocitose FcyR mediada. A maioria dos kits comerciais utilizam saída fluorescente para monitorizar a fagocitose (por exemplo, biopartículas, a proteína de fluorescência sensível ao pH, ou IgG-esferas de látex marcadas fluorescentes). O uso de saída fluorescente não oferecem quantificação mais objetiva, mas também é preciso conconsiderar as disponibilidade, custo, e de formação associada com o uso de um microscópio de fluorescência ou um citómetro de fluxo, bem como a dependência que se seguiu após kits disponíveis comercialmente.
Finalmente, este ensaio pode ser modificado, dependendo da questão de pesquisa. Por exemplo, no ensaio de inibição de droga de fagocitose, monócitos pode ser pré-tratado ou co-incubadas com ambos os fármacos e RBCs opsonizadas (ou seja, um ensaio de competição). A sinalização a jusante de anticorpos de diferentes subtipos, anticorpos quiméricos, ou construções recombinantes pode também ser testada. Com os recentes avanços no desenvolvimento de um sangue antígeno-nulo universal 24, o MMA poderia ser utilizada em telas iniciais desses hemácias antígeno-nulo com vários anticorpos para avaliar se há de fato uma eficácia reduzida no desencadeamento de fagocitose.
The authors have nothing to disclose.
The authors thank the Canadian Blood Services for a Graduate Fellowship Program Award to T.N.T. This research received financial support from the Canadian Blood Services’ Centre for Innovation, funded by the federal government (Health Canada) and the provincial and territorial ministries of health. The views herein do not reflect the views of the federal, provincial, or territorial governments in Canada.
Acid citrate dextrose (ACD) vacutainers | BD | REF364606 | |
RPMI 1640 | Sigma | R8758 | |
HEPES | Bioshop | HEP003.100 | |
Fetal bovine serum | Multicell | 080150 | |
Gentamicin | Gibco | 15710-64 | |
Ficoll-Paque PLUS | GE | 17-1440-03 | https://www.gelifesciences.com/ |
Phosphate buffered saline | Sigma | D8537 | |
8-chamber slides | Lab-Tek-ll | 154534 | |
R2R2 (cDE/cDE) red blood cells | Canadian Blood Services | Commercially available (e.g. http://www.bio-rad.com/en-ca/product/reagent-red-blood-cells) | |
Polyclonal anti-D from human serum | Gamma Biologics | DIN 02247724 | Can be substituted with commercially available monoclonal anti-D or with Rh immune globulin |
100% methanol | Caledon | 6700-1-42 | |
Polyvinyl alcohol resin | Sigma | P8136 | Can be substituted with commercially available mount |
UltraPure glycerine | Invitrogen | 15514-011 | |
Cover slips | VWR | 48366 067 | |
Novaclone anti-IgG | Immucorgamma | 5461023 | Optional for IAT (http://www.fda.gov/downloads/biologicsbloodvaccines/…/ucm081743.pdf) |