Summary

주요 조직 적합성 복잡한 클래스 II Dextramers을 사용하여 뇌와 심장에있는자가 반응 CD4 T 세포의 제자리 탐지에

Published: August 01, 2014
doi:

Summary

주요 조직 적합성 복합체 클래스 II dextramers 직접 염색으로 뇌와 심장 자기 반응성 CD4 T 세포를 감지하는 프로토콜은이 보고서에 설명되어 있습니다. 종합적인 분석을 위해, 시츄 항원 특이 CD4 + T 세포의 빈도를 열거하는 신뢰할 수있는 방법도 고안되어있다.

Abstract

This report demonstrates the use of major histocompatibility complex (MHC) class II dextramers for detection of autoreactive CD4 T cells in situ in myelin proteolipid protein (PLP) 139-151-induced experimental autoimmune encephalomyelitis (EAE) in SJL mice and cardiac myosin heavy chain-α (Myhc) 334-352-induced experimental autoimmune myocarditis (EAM) in A/J mice. Two sets of cocktails of dextramer reagents were used, where dextramers+ cells were analyzed by laser scanning confocal microscope (LSCM): EAE, IAs/PLP 139-151 dextramers (specific)/anti-CD4 and IAs/Theiler’s murine encephalomyelitis virus (TMEV) 70-86 dextramers (control)/anti-CD4; and EAM, IAk/Myhc 334-352 dextramers/anti-CD4 and IAk/bovine ribonuclease (RNase) 43-56 dextramers (control)/anti-CD4. LSCM analysis of brain sections obtained from EAE mice showed the presence of cells positive for CD4 and PLP 139-151 dextramers, but not TMEV 70-86 dextramers suggesting that the staining obtained with PLP 139-151 dextramers was specific. Likewise, heart sections prepared from EAM mice also revealed the presence of Myhc 334-352, but not RNase 43-56-dextramer+ cells as expected. Further, a comprehensive method has also been devised to quantitatively analyze the frequencies of antigen-specific CD4 T cells in the ‘Z’ serial images.

Introduction

주요 조직 적합성 복합체의 사용은 항원 특이 CD4 T 세포의 검출 (MHC) 클래스 II 테트라 도전 1-7이었다. MHC 클래스 II 테트라의 검출 감도를 향상시키기 위해, 연구팀은 지정된 차세대 테트라, "dextramers"8을 만들었습니다. Dextramers는 여러 가지 펩타이드 닿는, 바이오틴 MHC 단량체 한 덱스 트란 분자 9에 부착 할 수있는 여러 스트렙 타비 딘 – 형광 부분이 접합되는 덱스 트란 등뼈가 포함되어 있습니다. 따라서, 몇개의 MHC-펩티드 복합체를 포함하는 MHC dextramers의 큰 응집체가 다수의 T 세포 수용체 (TCR도)와 상호 작용할 수있다.

이 그룹은 최근 다양한 자기 항원에 대한 dextramers을 생성 dextramers의 검출 감도가 약 테트라 8보다 5 배 정도였다. 실험 시스템은 실험자가 면역 뇌척수염을 포함 (EAE) 테오 단백질 (PLP) SJL 마우스에서 139-151로 유도; EAE는 수초 희소 돌기 아교 세포의 당 단백질 (MOG) C57BL / 6 마​​우스에서 35-55로 유도; 실험자가 면역 심근염 (EAM)는 심장 미오신 중쇄-α (Myhc) A / J 생쥐에서 334-352로 유도. 이 연구는 PLP 139-151의 사용을 보여 – 및 Myhc 334-352함으로써 형광 항체를 사용하여 신호를 증폭 할 필요가 없어, 직접 염색 프로토콜을 개발함으로써 특이 반응계에서 항원 특이 CD4 T 세포를 검출 dextramers 접근 일반적으로 테트라의 사용과 채택했다. 또, 조직을 평가하는 포괄적 인 방법은 또한 안정적 시츄 (10) 항원 특이 CD4 T 세포의 빈도를 열거 고안되었다. 시츄 항원 특이 T 세포의 검출 와키 활성화로 인한 것과 특정 항원 자극에 의해 유발 사건 묘사를 허용한다. 마찬가지로,있는 현장 기술도 제공하기대상 기관에 항원 특이 T 세포 침윤의 동역학을 추적하는 에스 기회.

Protocol

윤리 문 : 모든 동물의 절차는 실험 동물의 관리 및 사용에 대한 지침에 따라 실시 및 네브래스카 링컨, 링컨, 네브래스카의 대학에 의해 승인되었습니다. EAE 1. 유도 단계 1.1 : EAE를 유도하기 위해, 다음의 수정 (11)에서 설명한 바와 같이 펩티드 / 완전 프로 인트 아쥬 반트 (CFA) 에멀션 제조. 1X 인산 완충 생리 식염수 (PBS)의 1 ㎎ / ㎖?…

Representative Results

이 보고서에서, MHC 클래스 II dextramers 직접 염색하여 항원 특이, 반응성 CD4 T 세포의 현장 검출에 설명되어 있습니다. 갓 잘라 뇌 섹션은 EAE 마우스에서 파생 된 (제어) dextramers 및 안티-CD4 (특정) 또는 TMEV 70 ~ 86 PLP 139-151을 포함하는 칵테일을 염색 하였다. 그림 1의 상단 패널은 이중 양성 세포가 노란색 등장 PLP 139-151 dextramers (빨강) 및 CD4 항체 (녹색)로 costained 대뇌 부분의 LSCM 분?…

Discussion

MHC 클래스 I 테트라와는 달리, 일상적인 응용 프로그램의 MHC 클래스 II 테트라의 사용은 특히 자신의 활성화 종속성 6,15-17에 부분적으로 인해 낮은 친화력자가 반응 CD4 T 세포의 전구체 주파수를 열거하는 도전되고 있습니다. 최근에,이 문제는 이러한 PLP 139-151, MOG 35-55과 Myhc 334으로자가 항원의 수를 항원 특이 CD4 T 세포를 감지하는 우리를 허용 ", dextramers"라고 사량의 다음 세대를 ?…

Divulgaciones

The authors have nothing to disclose.

Acknowledgements

이 작품은 미국 심장 협회와 어린이의 심장 근육 병증 재단 (SDG2462390204001)과 국립 보건원 (HL114669)에 의해 지원되었다. CM은 심근염 재단, NJ에 의해 수여 박사 학위 취득 후 연구 활동 보조금의 수상자이다.

Materials

CFA Sigma Aldrich, St Louis, MO 5881 Store at 4οC
MTB  H37Rv extract  Difco Laboratories, Detroit, MI 231141 Store at 4οC
PT List Biologicals Laboratories, Campbell, CA 181 Store at 4οC
1x PBS  Corning, Manassas, VA 21-040-CV Store at 4οC
Female A/J mice  Jackson Laboratories, Bar Harbor, ME 646
Female SJL/J mice Jackson Laboratories, Bar Harbor, ME 686
Leur-lok sterile 1 ml syrringe BD, Franklin Lakes, NJ 309628
Leur-lok sterile 3 ml syrringe BD, Franklin Lakes, NJ 309657
Sterile needle, 18 G BD, Franklin Lakes, NJ 305195
Sterile needle, 27 1/2 G BD, Franklin Lakes, NJ 305109
3-way stopcock  Smiths Medical ASD, Inc. Dublin, OH MX5311L
Kerlix gauze bandage rolls  Covidien, Mansfield, MA 6720
Kimwipes Kimberly-Clark Professional, Roswell, GA 34155
Agarose, Low Melting Point, Analytical Grade Promega corporation, Madison, WI V2111
Immunopure normal goat serum Thermo Scientific, Waltham, MA 31873 Store at -20 οC
Anti-mouse CD4 conjugated with PE dye eBioscience, San Diego, CA  12004185 Store at 4οC
Paraformaldehyde Electron Microscopy Sciences, Hatfield, PA 19202 Store at 4οC
Faramount Aqueous Mounting Medium Dako, Carpinteria, CA 10073021
Conical tube (15ml) BD Biosciences, San Jose, CA 352099
Conical tube (50 ml) BD Biosciences, San Jose, CA 352070
24-well flat bottomed tissue culture plates BD Biosciences, San Jose, CA 356775
Water color #2 brushes Charles Leonard, Inc. Hauppauge, NY 73502
Plain Microscope slides, size: 3" x 1" x 1.2 mm Fisher Scientific, Pittsburgh, PA 1255010
Premium Cover glass, 22 x 22-1 Fisher Scientific, Pittsburgh, PA 12548B
Disposable deep base mold histology cassettes Laboratory prodcust, Rochester, NY M-475-10
Loctite Super glue Henkel Corporation, Westlake, OH 1471879
Razor blades Gillette SuperSilver
Myhc-a 334-352 (DSAFDVLSFTAEEKAGVYK) Neopeptide, Cambridge, MA Store at 4οC
PLP 139-151 (HSLGKWLGHPDKF) Neopeptide, Cambridge, MA Store at 4οC
MHC class II/IAs PLP 139-151 or TMEV 70-86 dextramers conjugated with APC dye Store at 4οC
MHC class II/IAk Myhc 334-352 or  or RNase 40-56 dextramers conjugated with APC dye Store at 4οC
Dextran conjugated SA-APC  Immundex, Copenhagen, Demark Store at 4οC
Sterile surgical scissors and forceps INOX tool Corporation
Micro oven GE Healthcare, Pittsuburgh, PA
Leica VT 1200 Vibratome Leica Microsystems, Inc. Buffalo Grove, IL
Olympus BX 60  Laser scanning confocal microscope Olympus America, Inc. Center Valley, PA
Nikon A1-Eclipse 90i confocal microscope Nikon Inc. Melville, NY

Referencias

  1. Cecconi, V., Moro, M., Del Mare, ., Dellabona, S., P, G., Casorati, Use of MHC class II tetramers to investigate CD4+ T cell responses: problems and solutions. Cytometry A. 73 (11), 1010-1018 (2008).
  2. Ferlin, W., Glaichenhaus, N., Mougneau, E. Present difficulties and future promise of MHC multimers in autoimmune exploration. Curr Opin Immunol. 12, 670-675 (2000).
  3. Kwok, W. W., Ptacek, N. A., Liu, A. W., Buckner, J. H. Use of class II tetramers for identification of CD4+ T cells. J Immunol Methods. 268, 71-81 (2002).
  4. Landais, E., et al. New design of MHC class II tetramers to accommodate fundamental principles of antigen presentation. J Immunol. 183, 7949-7957 (2009).
  5. Nepom, G. T. MHC class II tetramers. J Immunol. 188, 2477-2482 (2012).
  6. Vollers, S. S., Stern, L. J. Class II major histocompatibility complex tetramer staining: progress, problems, and prospects. Immunology. 123, 305-313 (2008).
  7. Wooldridge, L., et al. Tricks with tetramers: how to get the most from multimeric peptide-MHC. Immunology. 126, 147-164 (2009).
  8. Massilamany, C., Upadhyaya, B., Gangaplara, A., Kuszynski, C., Reddy, J. Detection of autoreactive CD4 T cells using major histocompatibility complex class II dextramers. BMC Immunol. 12, 1471-2172 (2011).
  9. Batard, P., et al. Dextramers: new generation of fluorescent MHC class I/peptide multimers for visualization of antigen-specific CD8+ T cells. J Immunol Methods. 310 (1-2), 136-148 (2006).
  10. Massilamany, C., Gangaplara, A., Jia, T., et al. Direct staining with major histocompatibility complex class II dextramers permits detection of antigen-specific, autoreactive CD4 T cells in situ. PLoS One. 9 (1), (2014).
  11. Massilamany, C., Khalilzad-Sharghi, V., Gangaplara, A., Steffen, D., Othman, S. F., Reddy, J. Noninvasive Assessment of Cardiac Abnormalities in Experimental Autoimmune Myocarditis by Magnetic Resonance Microscopy Imaging in the Mouse. J Vis Exp. (88), e51654 (2014).
  12. Massilamany, C., Steffen, D., Reddy, J. An epitope from Acanthamoeba castellanii that cross-react with proteolipid protein 139-151-reactive T cells induces autoimmune encephalomyelitis in SJL mice. J Neuroimmunol. 219 (1-2), 17-24 (2010).
  13. Donermeyer, D. L., Beisel, K. W., Allen, P. M., Smith, S. C. Myocarditis-inducing epitope of myosin binds constitutively and stably to I-Ak on antigen-presenting cells in the heart. J Exp Med. 182 (5), 1291-1300 (1995).
  14. Liao, L., Sindhwani, R., Leinwand, L., Diamond, B., Factor, S. Cardiac alpha-myosin heavy chains differ in their induction of myocarditis. Identification of pathogenic epitopes. J Clin Invest. 92 (6), 2877-2882 (1993).
  15. Cameron, T. O., Cochran, J. R., Yassine-Diab, B., Sekaly, R. P., Stern, L. J. Cutting edge: detection of antigen-specific CD4+ T cells by HLA-DR1 oligomers is dependent on the T cell activation state. J Immunol. 166 (2), 741-745 (2001).
  16. Novak, E. J., et al. Activated human epitope-specific T cells identified by class II tetramers reside within a CD4high, proliferating subset. Int Immunol. 13 (6), 799-806 (2001).
  17. Reddy, J., et al. Detection of autoreactive myelin proteolipid protein 139-151-specific T cells by using MHC II (IAs) tetramers. J Immunol. 170 (2), 870-877 (2003).
  18. Skinner, P. J., Daniels, M. A., Schmidt, C. S., Jameson, S. C., Haase, A. T. Cutting edge: In situ tetramer staining of antigen-specific T cells in tissues. J Immunol. 165 (2), 613-617 (2000).
  19. Skinner, P. J., Haase, A. T. In situ tetramer staining. J Immunol Methods. 268 (1), 29-34 (2002).
  20. Skinner, P. J., Haase, A. T. In situ staining using MHC class I tetramers. Curr Protoc Immunol. Chapter 17, Unit 17.14.11 (2004).

Play Video

Citar este artículo
Massilamany, C., Gangaplara, A., Jia, T., Elowsky, C., Li, Q., Zhou, Y., Reddy, J. In Situ Detection of Autoreactive CD4 T Cells in Brain and Heart Using Major Histocompatibility Complex Class II Dextramers. J. Vis. Exp. (90), e51679, doi:10.3791/51679 (2014).

View Video