Traditional slab gel electrophoresis (SGE) experiments require a complicated apparatus and high chemical consumption. This work presents a protocol that describes a low-cost method to separate DNA fragments within a short timeframe.
Slab gel electrophoresis (SGE) is the most common method for the separation of DNA fragments; thus, it is broadly applied to the field of biology and others. However, the traditional SGE protocol is quite tedious, and the experiment takes a long time. Moreover, the chemical consumption in SGE experiments is very high. This work proposes a simple method for the separation of DNA fragments based on an SGE chip. The chip is made by an engraving machine. Two plastic sheets are used for the excitation and emission wavelengths of the optical signal. The fluorescence signal of the DNA bands is collected by smartphone. To validate this method, 50, 100, and 1,000 bp DNA ladders were separated. The results demonstrate that a DNA ladder smaller than 5,000 bp can be resolved within 12 min and with high resolution when using this method, indicating that it is an ideal substitute for the traditional SGE method.
Slab gel electrophoresis (SGE) is the most effective method for DNA fragment separation1,2,3,4,5 and thus it is deemed a versatile tool in biochemical and biological analyses6,7,8. However, many experiments indicate that SGE is restricted by the following four problems: (1) the separations take many hours, and even days; (2) the chemical consumption is very high; (3) it requires a complicated apparatus (e.g., 2D electrophoresis cell, electrophoresis power supply, and gel imaging system); (4) the gel imaging system can only observe the separated DNA fragments when the experiment is finished. Furthermore, ethidium bromide (EtBr), which is commonly used in SGE9,10, is mutagenic and cancerogenic11,12. Thus, gloves should always be worn when handing gels containing EtBr.
Capillary electrophoresis (CE) has numerous advantages13,14,15,16,17 compared to SGE, such as automatic operation, short separation time, and lower consumption. However, the CE instrument is quite expensive. Therefore, to overcome those limitations, a system has been developed (Figure 1) for the separation of DNA. Such a system can not only greatly reduce the chemical consumption and save on SGE experiment time (<8 min), but it can also perform real-time tracking of the DNA separation process in the agarose gel by smartphone. By following the procedures described in this protocol, students should be able to design and fabricate the SGE chip, prepare the agarose gel in the chip, set up a simple SGE system with a smartphone, and record the DNA migration process in the agarose gel.
1. Basic Design of the SGE Chip
2. Preparation of the Agarose Gel
3. Running the Electrophoresis in the SGE Chip
Figure 4, Figure 5, and Figure 6 represent a typical result after the gel electrophoresis of 50, 100, and 1,000 bp DNA ladders. After the experiment, the DNA fragments were well-separated. Furthermore, the same samples were separated in the 4 channels of the SGE chip, showing that DNA fragments of the same size move the same distance in each experiment.
The separation performance of the DNA ladder can be evaluated by analyzing the relationship of the migration distance and the logarithm of DNA size; thus, SGE can be applied to calculating the size of unknown DNA fragments. In Figure 3, it was found that the migration distance is linearly related to the logarithm of DNA size when the DNA size is smaller than 700 bp.
Figure 1: Schematic and images. (A) A schematic diagram of the real-time tracking DNA separation system. It includes the LED array as the light source, the optical filter, and the CGE chip. The smartphone can record the DNA migration process. (B) The SGE chip. (C) The device assembled for electrophoresis. Please click here to view a larger version of this figure.
Figure 2: A student loading the gel. Please click here to view a larger version of this figure.
Figure 3: A student recording the migration on a smartphone. Please click here to view a larger version of this figure.
Figure 4: Separation of 50-bp DNA ladders on the SGE chip. The geometric parameters for the channel in the SGE chip are 2.5 mm x 4.0 mm x 90 mm (width x depth x length). The separation voltage is 120 V. Please click here to view a larger version of this figure.
Figure 5: Separation of 100-bp DNA ladders on the SGE chip. The geometric parameters for the channel in the SGE chip are 2.5 mm x 4.0 mm x 90 mm (width x depth x length). The separation voltage is 120 V. Please click here to view a larger version of this figure.
Figure 6: Separation of 1,000-bp DNA ladders on the SGE chip. The geometric parameters for the channel in the SGE chip are 3.6 mm x 4.0 mm x 90 mm (width x depth x length). The separation voltage is 180 V. Please click here to view a larger version of this figure.
Agarose gel electrophoresis is widely employed for the separation of DNA, RNA, and protein. This work proposes a new method to replace the traditional gel electrophoresis protocol. Results demonstrate that 50, 100, and 1,000 bp DNA ladders can be separated well in such a small assembled device. The great advantage of this method is that not only can it separate the nucleic acids with little chemical consumption, but it can also record the separation process. Although the DNA fragments looks wide in Figure 2, the results can be improved by optimizing the parameters of the SGE chip and the concentration of the agarose gel. Furthermore, the total SGE process takes no more than 10 min if precast gels are used in the chip.
The separation performance of the DNA ladder is quite different if the channel width in the chip is changed. For example, when a 1,000-bp DNA ladder is separated, the DNA band looks wider if the width of the channel is small. This is possibly because the joule heating in the agarose gel is very high18, which affects the separation performance.
The SGE method proposed here is very simple. A portable mini-SGE device can be developed if the system is optimized. Such a device can be applied to point-of-care laboratory testing.
The authors have nothing to disclose.
We gratefully acknowledge support from National Natural Science Foundation of China (No. 21205078) and the Research Fund for the Doctoral Program of Higher Education of China (No.20123120110002). This work was partially supported by the National Key Research and Development Program of China (2016YFB1102303), the National Basic Research Program of China (973Program; 2015CB352001), and the National Natural Science Foundation of China (61378060).
10×TBE | Beijing Solarbio Science & Technology Co., Ltd. | T1051 |
50bp DNA ladder | Takara Bio Inc. | 3421A |
100bp DNA ladder | Takara Bio Inc. | 3422A |
1kbp DNA ladder | Takara Bio Inc. | 3426A |
SYBR GREEN | Takara Bio Inc. | 5760A |
Agarose | Sigma-Aldrich Corporate | V900510 |