Summary

분석 미세 유체 장치의 열 측정 기술

Published: June 03, 2015
doi:

Summary

Here, we present three protocols for thermal measurements in microfluidic devices.

Abstract

Thermal measurement techniques have been used for many applications such as thermal characterization of materials and chemical reaction detection. Micromachining techniques allow reduction of the thermal mass of fabricated structures and introduce the possibility to perform high sensitivity thermal measurements in the micro-scale and nano-scale devices. Combining thermal measurement techniques with microfluidic devices allows performing different analytical measurements with low sample consumption and reduced measurement time by integrating the miniaturized system on a single chip. The procedures of thermal measurement techniques for particle detection, material characterization, and chemical detection are introduced in this paper.

Introduction

세 가지 다른 마이크로 크기의 열 측정 기술은이 문서에 제시되어있다. 미세 유체 장치의 세 가지 상이한 구성은 열 입자 검출부 (TPD), 열적 특성 (열전도율 및 비열), 및 화학 반응과 상호 작용 열량 검출에 사용된다.

열 입자 검출

검출 및 미세 유체 장치에서 입자를 계산하는 것은 널리, 환경 산업, 생물 응용 프로그램 (1)에 사용됩니다. TPD는 미세 유체 장치 2 열 측정의 새로운 응용 프로그램 중 하나입니다. 검출 및 입자 크기에 기초하여 입자를 계수 열 전달을 사용하여 시스템의 복잡성, 비용 및 크기를 감소시킨다. 다른 방법, 복잡한 광학 또는 복잡한 전기 측정 및 고급 신호 처리 소프트웨어에서 입자를 검출하기 위해 사용된다.

열 체인지마이크로 열량계를 사용하여 액체 물질의 cterization

액체 시료의 열 특성은 미세 유체 장치의 열 측정의 두 번째 응용 프로그램입니다. 마이크로 스케일 열량을 수행하면 샘플 소모를 줄이고, 종래의 벌크 열량 방법에 비해 더 높은 반복성을 제공하여 정확도를 증가시킬 것이다. 온 – 칩 마이크로 – 열량계 장치를 이용하여 열전도율 및 비열 측정을위한 절차는 다른 제시된다. 열전도율 측정 용 히트 침투 시간 기술 및 마이크로 유체 디바이스들에서 비열 측정을위한 열 파 분석 (TWA)의 세부 사항은 프로토콜 절에서 설명된다.

열량 바이오 화학에있는 검색, 탐지 종이 기반 미세 유체 소자

열 측정의 또 다른 응용 프로그램은 종이 기반 미세 유체에서 생화학 감지입니다. 에서 모세관 작용종이의 다공질 구조가 액체를 운반 마이크로 채널 거품 개시 문제를 피할 수있다. 종이 기반의 미세 유체 소자에서 가장 일반적인 검출 메커니즘은 광학 또는 전기 화학적 기술이다. 광 검출은 높은 복잡성 앓고 고급 화상 처리 소프트웨어의 필요성이 검출 된 신호를 양자화하는. 이들은 활성 반응 부산물을 생산에 적용 할 수 있기 때문에, 전기 화학 탐지가 또한 제한된다. 최근 소개 열량 종이 기반 생화학 센서 플랫폼 (4)은 종이 기반 마이크로 유체 시스템 및 라벨없는 열 감지 메커니즘을 이용한다. 종이 기반의 미세 유체 플랫폼에 글루코스 옥시 다제 (GOD) 효소를 이용한 글루코스의 열량 검출 절차는 프로토콜 부분에 제시되어있다.

본 연구의 목적은 미세 유체 소자에서 열 측정 기술의 능력을 입증하는 것이다. 장치 혼합물 준비N, 액체 시료 처리 및 저항 온도 감지기 (RTD) 센서 여기 및 측정은 다음 절에 제시되어있다.

Protocol

1. 열 입자 감지 (TPD) 표준 반도체 공정 기술을 이용하여 2, 마이크로 머신에 의한 박막 실리콘 질화물 막, 및 온도 센서가 내장 마이크로 제조 실리콘 장치를 준비한다. 탈 (DI) 물 제조 장치를 씻어. 주 : 열 입자 탐지기를위한 미세 유체 소자의 제조 방법은 선행 문헌 2에 설명되어있다. 마이크로 채널이 폴리 디메틸 실록산 (PDMS) 기판을 제조, (5)를</s…

Representative Results

그림 3은 측정 된 온도 신호의 플롯을 보여줍니다. 해당 광학 이미지 비드의 존재 하에서 생성 된 신호는 마이크로 채널에서 미세 구 PS 비드의 성공적인 검출을 나타낸다. 마이크로 채널을 통과하는 액체의 열전도 PS 비드의 존재로 인해 변경된다. 채널의 열전도율의 변화는 마이크로 채널에서의 열전달에 영향을주지한다. 마이크로 채널에서의 열 전달의 변화는 저항의 변동 (?…

Discussion

Different thermal measurement techniques in microfluidic devices and their respective setup procedures are presented in this work. These thermal measurement methods such as thermal conductivity monitoring, thermal penetration time, amplitude of AC thermal fluctuations, and amplitude measurement of the generated heat are used to detect specific substances and investigate different reactions and interactions.

The thermal time constant plays a key role in the aforementioned thermal measurement t…

Offenlegungen

The authors have nothing to disclose.

Acknowledgements

이 작품에 대한 부분적인 재정 지원은 물 장비 및 위스콘신 – 밀워키 (IIP-0968887)과 마켓 대학 (IIP-0968844)의 대학에있는 정책에 대한 산업 / 대학 협동 연구 센터를 통해 미국 국립 과학 재단 (National Science Foundation)에 의해 제공되었다. 우리는 도움이 토론 글렌 M. 워커, 우 진 장과 샨 Radhakrishnan 감사합니다.

Materials

Polydimethylsiloxane (PDMS)  Dow Corning Sylgard 184
PS beads – 90 um  Corpuscular 100265
PS beads – 200 um  Corpuscular 100271
Glycerol SigmaAldrich G5516
GOD enzyme SigmaAldrich G7141
Glucose Control Solution-Low Bayer contour Low Control
Glucose Control Solution-Normal Bayer contour Normal Control
Glucose Control Solution-High Bayer contour High Control
Chromatography filter paper Whatman 3001-845
Glass VWR  48393-106
Acrylic Film Nitto Denko 5600
Glass syringe (1 mL) Hamilton 1001
Syringe pump New Era NE-500
knife plotter Silhouette portrait
Current Preamplifier Stanford Research SR-570
Ocilloscope Agilent DSO 2420A
Signal Generator HP HP3324A
Lock-in Amplifire Stanford Research SRS-830
Source/meter 2400 Keithley 2400
Source/meter 2600 Keithley 2436A

Referenzen

  1. Zhang, H., Chon, C., Pan, X., Li, D. Methods for counting particles in microfluidic applications. Microfluid Nanofluid. 7 (6), 739-749 (2009).
  2. Vutha, A. K., Davaji, B., Lee, C. H., Walker, G. M. A microfluidic device for thermal particle detection. Microfluid Nanofluid. 17 (5), 871-878 (2014).
  3. Davaji, B., Bak, H. J., Chang, W. J., Lee, C. H. A Novel On-chip Three-dimensional Micromachined Calorimeter with Fully Enclosed and Suspended Thin-film Chamber for Thermal Characterization of Liquid Samples. Biomicrofluidics. 8 (3), 034101-034113 (2014).
  4. Davaji, B., Lee, C. H. A paper-based calorimetric microfluidics platform for bio-chemical sensing. Biosens. Bioelectron. 59, 120-126 (2014).
  5. Liu, J., et al. Process research of high aspect ratio microstructure using SU-8 resist. Microsystem Technologies. 10, 265-268 (2004).
  6. Dusen, M. S. V. Platinum-resistance thermometry at low temperatures. J. Am. Chem. Soc. 47 (2), 326-332 (1925).
  7. Arpaci, V. S. . Conduction Heat Transfer. , (1966).
  8. Garden, J. L., Chteau, E., Chaussy, J. Highly sensitive ac nanocalorimeter for microliter-scale liquids or biological samples. Appl. Phys. Lett. 84, 3597-3599 (2004).
  9. Kilo, C., et al. Evaluation of a New Blood Glucose Monitoring System with Auto-Calibration. Diabetes Technol. Ther. 7 (2), 283-294 (2005).
  10. Scheper, T. . Thermal Biosensors Bioactivity Bioaffinity (Advances in Biochemical Engineering/Biotechnology). , (1999).

Play Video

Diesen Artikel zitieren
Davaji, B., Lee, C. H. Thermal Measurement Techniques in Analytical Microfluidic Devices. J. Vis. Exp. (100), e52828, doi:10.3791/52828 (2015).