This movie shows how an atmospheric plasma torch can be ignited by microwaves with no additional igniters and provides a stable and continuous plasma operation suitable for plenty of applications.
This movie shows how an atmospheric pressure plasma torch can be ignited by microwave power with no additional igniters. After ignition of the plasma, a stable and continuous operation of the plasma is possible and the plasma torch can be used for many different applications. On one hand, the hot (3,600 K gas temperature) plasma can be used for chemical processes and on the other hand the cold afterglow (temperatures down to almost RT) can be applied for surface processes. For example chemical syntheses are interesting volume processes. Here the microwave plasma torch can be used for the decomposition of waste gases which are harmful and contribute to the global warming but are needed as etching gases in growing industry sectors like the semiconductor branch. Another application is the dissociation of CO2. Surplus electrical energy from renewable energy sources can be used to dissociate CO2 to CO and O2. The CO can be further processed to gaseous or liquid higher hydrocarbons thereby providing chemical storage of the energy, synthetic fuels or platform chemicals for the chemical industry. Applications of the afterglow of the plasma torch are the treatment of surfaces to increase the adhesion of lacquer, glue or paint, and the sterilization or decontamination of different kind of surfaces. The movie will explain how to ignite the plasma solely by microwave power without any additional igniters, e.g., electric sparks. The microwave plasma torch is based on a combination of two resonators — a coaxial one which provides the ignition of the plasma and a cylindrical one which guarantees a continuous and stable operation of the plasma after ignition. The plasma can be operated in a long microwave transparent tube for volume processes or shaped by orifices for surface treatment purposes.
Atmospheric pressure microwave plasma torches offer a variety of different applications. On one hand they can be used for chemical volume processes and on the other hand their afterglow plasma can be applied for the treatment of surfaces. As surface treatment processes the treatment to increase the adhesion of glue, paint or lacquer or the decontamination or sterilization of surfaces can be named. The hot and reactive plasma itself can be used for volume processes like the decomposition of waste gases 1–7. These waste gases are harmful, contribute to the global warming and can hardly be degraded conventionally. However, they are needed in growing industrial sectors such as the semiconductor branch. Other applications are chemical synthesis like the dissociation of CO2 to CO and O2 or CH4 to carbon and hydrogen 8,9. Surplus electrical energy from renewable energy sources can be used to dissociate CO2 into CO and O2. The CO can be processed further to higher hydrocarbons which can be used as synthetic fuels for transportation, as platform chemicals for the chemical industry or as chemical storage.
There are some microwave plasma torches but most of them have disadvantages: They only have very small plasma volumes, need additional igniters, need cooling of the plasma reactor or can only be operated in pulsed mode 10–18. The microwave plasma torch presented in this movie offers an ignition of the plasma solely with the provided microwave power with no additional igniters as well as a stable and continuous operation without any cooling of the plasma reactor for a broad range of operation parameters and can be used for all of the above mentioned applications. The microwave plasma torch is based on a combination of two resonators: a coaxial one and a cylindrical one. The cylindrical resonator has a low quality and is operated in the well-known E010-mode with the highest electrical field in its center. The coaxial resonator is located below the cylindrical resonator and consists of a movable metallic nozzle in combination with a tangential gas supply. The high quality of the coaxial resonator exhibits a very narrow but deep resonance curve. Due to the high quality of the coaxial resonator a high electrical field can be reached which is required for the ignition of the plasma. However, the high quality of the coaxial resonator is associated with a very narrow resonance curve and therefore the resonance frequency has to perfectly match the frequency of the supplied microwave. Since the resonance frequency shifts after ignition of the plasma due to the permittivity of the plasma, the microwave can no longer penetrate into the coaxial resonator. For the continuous operation of the plasma the cylindrical resonator with a low quality and a broad resonance curve is needed.
An additional axial gas supply via the metallic nozzle of the coaxial resonator is possible. The plasma is ignited and confined in a microwave-transparent tube, for example a quartz tube. The permittivity of the quartz tube also affects the resonance frequency. Since the quartz has a permittivity of > 1, the volume of the cylindrical resonator is virtually enlarged which leads to a lower resonance frequency. This phenomenon has to be considered when the dimensions of the cylindrical resonator are designed. A detailed discussion about how the resonance frequency is affected by the inserted quartz tube can be found in Reference 23. If a long and extended quartz tube is used, this can also act as the reaction chamber for the volume processes. However, for surface treatments the plasma can also be shaped differently by different kind of orifices. The microwave is supplied via a rectangular waveguide from the magnetron. To avoid noise nuisance the use of a low ripple magnetron is recommended. The magnetron which is used in the movie is a low ripple one.
For the ignition of the plasma the high quality coaxial resonator is used while a stable and continuous operation is provided by the cylindrical resonator. To achieve the ignition of the plasma by the high quality coaxial resonator the resonance frequency of this resonator has to perfectly match the frequency of the microwave provided by the used magnetron. Since all magnetrons do not emit their microwave frequency at exactly the nominal frequency and since the frequency is dependent on the output power, the magnetron has to be measured with a spectrum analyzer. The resonance frequency of the coaxial resonator can be adjusted by moving the metallic nozzle up and down. This resonance frequency can be measured and thereby also adjusted to the sending frequency of the used magnetron with a network analyzer. To reach the high electrical field at the tip of the nozzle, required for the ignition of the plasma, a three stub tuner is needed in addition. This three stub tuner is a commonly used microwave component. The three stub tuner is mounted between the microwave plasma torch and the magnetron. After the resonance frequency of the coaxial resonator is adjusted, the forward power is maximized and the reflected power minimized by iteratively adjusting the stubs of the three stub tuner.
After having adjusted the resonance frequency of the coaxial resonator as well as having maximized the forward powers by means of the three stub tuner, the plasma of the microwave plasma torch can be ignited when the microwave plasma torch is connected to a magnetron. For the ignition of the plasma a minimum microwave power of about 0.3 to 1 kW is sufficient. The plasma ignites in the coaxial resonator. After the ignition of the plasma the resonance frequency of the coaxial resonator is shifted due to the dielectric permittivity of the plasma and the microwave can no longer penetrate into the coaxial resonator. Thus, the plasma switches from the coaxial mode into its much more extended cylindrical mode burning freely-standing above the metallic nozzle in the center of the cylindrical resonator. Since the quality of the cylindrical mode is very low and therefore exhibits a broad resonance curve, the microwave can still penetrate into the cylindrical resonator despite of the shift of the resonance frequency due to the dielectric permittivity of the plasma. Thus, a continuous and stable operation of the plasma in the cylindrical mode is provided by the microwave plasma torch. However, to reach a complete absorption of the supplied microwave power, the stubs of the three stub tuner have to be readjusted. Otherwise the supplied microwave power is not completely absorbed by the plasma but some percentage of the provided microwave is reflected and absorbed by the water load.
To examine the ignition of the plasma in the coaxial mode and then its transition into the extended cylindrical mode, the plasma ignition is observed by a high speed camera.
The presented movie will show how the frequency dependence of the magnetron is measured, the resonance frequency of the coaxial resonator is adjusted, how the forward power is maximized and how the plasma is ignited by the supplied microwave power. The high speed camera recording is shown as well.
1. Measurement of the Magnetron
Note: The schematic of the experimental setup for measuring the magnetron is depicted in Figure 1A.
2. Adjustment of the Resonance Frequency
Note: The schematic of the experimental setup for measuring and adjusting the resonance frequency is depicted in Figure 2A.
3. Ignition of the Plasma
4. High-speed Camera Movie of the Plasma Ignition
Note: Since the ignition of the plasma and its transition to the cylindrical mode is in the range of some hundred milliseconds, this process can best be investigated by means of a high speed camera. However, it is not necessary to observe the ignition process by means of a high speed camera each time the plasma is ignited.
5. Stable and Continuous Plasma Operation
Note: When the plasma has been ignited in the cylindrical mode and the three stub tuner has been adjusted to maximize the absorption of the microwave power by the plasma a stable and continuous operation of the plasma torch is possible.
To provide a plasma ignition without any additional igniters as well as a stable and continuous plasma operation a high quality coaxial resonator with an adjustable resonance frequency was combined with a low quality cylindrical resonator to a microwave plasma torch. The schematic of this plasma torch is presented in Figure 3. The plasma is confined into a microwave-transparent tube, here a quartz tube. This tube can act as a reaction chamber for volume plasma processes or a plasma brush for surface treatments can be formed by an orifice. The microwave power is guided via a rectangular waveguide from the magnetron to the microwave plasma torch. Different kinds of gases can be supplied via either the tangential gas supply or axially through the metallic nozzle of the coaxial resonator. The microwave plasma torch is equipped with a frontal slit, so that the plasma inside the torch and the ignition can be investigated in detail.
To guarantee an ignition of the plasma solely by the supplied microwave power a high electrical field of about 3 to 6 MV/m is needed. To get a better understanding of the electrical field distribution, simulations of the electric field distribution as well as Eigenmode analysis with the commercially available simulation software COMSOL Multiphysics were conducted. Modeling and simulations of electrical field distributions of atmospheric pressure microwave plasma torches provided already detailed insights and led to further developments and improvements regarding for example their ignition or operation behavior 19–22.
The electrical field distribution of the coaxial mode as well as of the common cylindrical E010 mode is depicted in Figure 4a and 4b, respectively. The electrical field is displayed in arbitrary units, since the electrical field in the coaxial resonator is many times higher compared to the electrical field in the cylindrical resonator. It can be seen that a high electrical field at the nozzle tip is reached with the coaxial resonator and the highest electrical field of the cylindrical resonator is in the center of the cylindrical resonator. The resonance frequency of the coaxial resonator can be varied by the position of the metallic nozzle. The simulation results for the resonance frequencies for different nozzle positions for a microwave plasma torch with a cylindrical resonator with a radius of 0.05 m and a height of 0.048 m are shown in the diagram in Figure 4C. It can be seen that the resonance frequency of the cylindrical mode is not affected by the position of the metallic nozzle. However, the resonance frequency of the coaxial mode is dependent on the nozzle position and decreases when the metallic nozzle is moved upwards into the cylindrical resonator.
To reach the required high electrical field in the coaxial resonator this resonance-frequency-adjustable coaxial resonator exhibits a high quality and a sharp and narrow resonance curve. However, a sharp and narrow resonance curve requires that the resonance frequency of the coaxial resonator matches perfectly the frequency of the supplied microwave. Since usually magnetrons do not emit the microwave at their nominal frequency and since the frequency of the microwave is dependent on the output power of the microwave, the frequency dependence of the magnetron has to be measured by means of a directional coupler and a spectrum analyzer. The experimental set-up to measure the frequency dependence of the magnetron with a spectrum analyzer is schematically given in Figure 1a. The measured frequency dependence of the utilized magnetron is shown in the diagram in Figure 1B. The center frequency was set to 2.45 GHz and the video bandwidth was 200 MHz. It can be seen that at a power of 200 W (10% of the maximum output power of the magnetron) the frequency of the microwave is at 2.44638 GHz and increases when the microwave power is increased. At the maximum output power of 2 kW the microwave frequency reaches a value of 2.45213 GHz.
The resonance frequency of the microwave plasma torch can be measured with a network analyzer and since the nozzle is movable the resonance frequency of the coaxial resonator can be adjusted. To do so, the microwave plasma torch assembly has to be connected to a network analyzer via a rectangular-to-coaxial waveguide transition as shown in the schematic in Figure 2A. By measuring the S11 parameter of the microwave plasma torch assembly the resonance frequency can be determined. The S11 parameter represents the ratio of the input power to the reflected power in dependence of the frequency. When a resonance is reached, an electrical field establishes in the resonator structure leading to a reduced reflected microwave power. However, the field strength inside the cavity is directly related to the fixed wave amplitude of the microwave provided by the network analyzer. A dip appears in the S11 spectrum which corresponds to the resonance frequency. A typical measurement of the S11 parameter is depicted in Figure 2B. Here a resonance is observed at a frequency of 2.846 GHz. By moving the metallic nozzle up and down, the resonance frequency of the coaxial resonator can be varied as the simulations depicted in Figure 4C showed. This dependence of the resonance frequency of the coaxial resonator on the metallic nozzle position can be measured by means of the S11 parameter. A measurement of the resonance frequency in dependence of the nozzle position and the appertaining simulation results are presented in the diagram in Figure 2C. This diagram shows that there is a good agreement between the simulation results and the measured values of the resonance frequency. The very small shift of the two curves can be explained by very small deviations of the geometry or dimension of the manufactured nozzle compared to the one used for the simulations. To adjust the resonance frequency of the coaxial resonator to the frequency of the supplied microwave, the metallic nozzle has to be iteratively moved up and down until the dip in the S11 parameter is located at the measured microwave frequency. Then the metallic nozzle has to be locked and the forward power can be maximized by iteratively adjusting the stubs of the three stub tuner so that the S11 parameter dip reaches its maximum depth. The high quality of the resonator and the maximized forward power lead to fewer microwave reflections and a high electrical field is established in the resonator which is why a deep dip in the S11 parameter results.
After the microwave plasma torch assembly is mounted to the magnetron and the gas supply is connected, the plasma torch can be ignited and operated. The ignition of the plasma can be investigated best by observing the ignition with a high speed camera. The ignition of the plasma was recorded at 1,000 fps. The presented plasma ignition was conducted at a microwave power of 1 kW and a supplied gas flow of 15 slm air. Images of each phase of the ignition are summarized in Figure 5. The image in Figure 5A shows the view from above, looking down on the nozzle at an angle through the diagnostic slit at the front of the inoperational plasma torch. The bottom of the cylindrical resonator is in the front. In the mid plane you can see the beginning of the coaxial resonator. The tip of the nozzle can also be seen. The bottom of the cylindrical resonator is located in the background again. Since the focus is on the nozzle tip, the bottom of the cylindrical resonator is somewhat blurry. The other images show the phases of the plasma ignition. When the microwave power is turned on at t = 0 msec, the plasma ignites somewhere in the coaxial resonator as can be seen in Figure 5B. Then, during 64 msec, the plasma winds up the metallic nozzle to its tip and then burns straight at the nozzle tip in the coaxial mode as the Figure 5C auf 5E show. The intensity of the plasma grows for the following 692 msec as it is shown in Figure 5F. Then, due to the shift of the resonance frequency caused by the burning plasma in the coaxial resonator 1 msec later, the plasma starts to break away from the nozzle tip as shown in Figure 5G and 5H. The complete break away of the plasma from the nozzle tip is reached after 58 msec as depicted in Figure 5I. The plasma is now burning freely above the metallic nozzle in the cylindrical mode. During the last second, the three stub tuner is readjusted to maximize the forward microwave power. This leads to an increase of the plasma as the image in Figure 5J shows. However, the plasma is still burning freely above the nozzle tip with no contact to it. Due to the low quality of the cylindrical resonator the plasma can be operated continuously and stably in this cylindrical resonator mode.
The dimension of the plasma depends on the supplied microwave power and the gas flow. Photos of the plasma for microwave powers of 1 and 2 kW and gas flows of 10, 30 and 70 slm are presented in Figure 6. The resonator with its diagnostic slit at its front is located in the lower part of the photos. The plasma is confined into a quartz tube within and above the cylindrical resonator. UV light couples into the quartz tube which is why the quartz tube exhibits a bluish glowing. It can be seen that the dimensions — radial and also the axial extension — of the plasma increase with an increase of the supplied microwave power while an increase of the gas flow leads to a smaller plasma flame. However, measurements of the gas and electron temperature show the maximum temperatures of Tg = 3,600 K and electron temperature Te = 5,800 K are independent of the outer parameters, supplied microwave power and gas flows, as well as of the plasma volume 19. The temperatures were obtained by means of optical emission spectroscopy. The A2Σ+ – X2Πγ-transition of the free OH radical was used for the determination of the gas temperature while a Boltzmann-plot of atomic oxygen lines was conducted for the estimate of the electron temperature. A detailed description on how the temperatures have been measured and the complete temperature distributions can be found in References 23 and 24.
To treat surfaces in the afterglow of the plasma, the plasma can be shaped with different kinds of orifices. Figure 7 depicts photos of differently shaped plasmas. The layout is similar to the photos of the plasma confined to a long quartz tube: the cylindrical resonator is at the bottom of the image; its diagnostic slit illuminated by the plasma. Differently shaped plasmas can be seen burning above the top-opening. On the photo in Figure 7A the confining quartz tube does not extend outside of the resonator. The plasma can burn freely above the resonator. An extended plasma brush can be formed with as slit orifice as depicted in Figure 7B. A plasma needle can be achieved by using an orifice with a hole in its center. This is shown in Figure 7C. Very small and smooth afterglow plasmas are formed by orifices which have a narrow slit or some small holes arranged in a circle as the photos in Figure 7D and 7E show.
Figure 1. Measurement of the magnetron. The schematic in (A) shows how the frequency dependence of a magnetron of the microwave output power can be measured by means of a spectrum analyzer. The frequency dependence of the used magnetron of the output power is depicted in (B). Please click here to view a larger version of this figure.
Figure 2. Measurement of the resonance frequency. The setup for the measurement and adjustment of the resonance frequency of the microwave plasma torch by means of a network analyzer is given in (A). (B) shows a typical measurement of the S11 parameter. The dip in the S11 parameter reflects the resonance frequency of the microwave plasma torch. The measured dependence of the resonance frequency on the metallic nozzle position and the results of the numerical simulations are summarized in c). Please click here to view a larger version of this figure.
Figure 3. Plasma torch setup. Schematic of the setup of the atmospheric microwave plasma torch. Please click here to view a larger version of this figure.
Figure 4. Coaxial and cylindrical mode. The distribution of the electrical field strength is depicted in (A) and (B). (A) shows the distribution for the coaxial mode while (B) shows the one for the cylindrical mode. The diagram in (C) shows the dependence of the resonance frequency of both the coaxial and the cylindrical mode on the position of the metallic nozzle in the plasma torch. The resonator has a diameter of 0.05 m and a height of 0.0482 m. Please click here to view a larger version of this figure.
Figure 5. Ignition of the plasma. Images of each phase of the ignition of the plasma recorded by a high speed camera at 1,000 fps and at a microwave power of 1 kW and a gas flow of 15 slm air. (A) View from above, looking down on the nozzle at an angle through the diagnostic slit at the front of the inoperational plasma torch. (B) Ignition of the plasma in the coaxial resonator. (C) – (E) Winding up of the plasma to the tip of the metallic nozzle until it burns in the coaxial mode. (F) The plasma increases. (G) – (I) The plasma breaks away from the metallic nozzle and burns freely above the nozzle tip in the cylindrical mode. (J) The plasma increases due to the readjustment of the three stub tuner to maximize the forward power. Please click here to view a larger version of this figure.
Figure 6. Photos of an air plasma for different supplied gas flows of 10, 30 and 70 slm and microwave powers of 1 and 2 kW. The extent of the plasma depends on the supplied microwave power and gas flow and it increases with an increase of the microwave power and a decrease of the gas flow. Please click here to view a larger version of this figure.
Figure 7. Different orifices. By using differently shaped orifices the plasma can be formed. (A) The confining quartz tube does not extend outside of the resonator and the plasma can burn freely above the resonator. (B) The plasma is shaped into a brush with a slit orifice. (C) A plasma needle is formed by a hole orifice. (D) A very smooth plasma brush can be achieved by using an orifice with a narrow slit and (E) a smooth plasma area is formed by an orifice with some small holes arranged in a circle. Please click here to view a larger version of this figure.
The presented movie explains how an ignition of an atmospheric pressure microwave plasma without any additional igniters can be realized, the basic principles of this microwave plasma torch, its adjustment, the ignition process of the plasma and its stable and continuous operation. As described in the introduction, there are already different kinds of microwave plasma torches but none of those provide an ignition of the plasma without any additional igniters as well as stable and continuous plasma operation.
To obtain an ignition of the plasma without any additional igniters at atmospheric pressure a high electrical field is necessary and therefore a resonator with a high quality while for a continuous and stable plasma operation a low quality is needed. This can be realized by combining a high quality coaxial resonator which guarantees the ignition of the plasma and a low quality cylindrical resonator which provides a continuous and stable plasma operation.
The frequency of the supplied microwave has to perfectly match the resonance frequency of the high quality coaxial resonator so that the provided power is coupled into the resonance chamber. Therefore the frequency dependence of the magnetron has to be well known and the resonance frequency of the coaxial resonator has to be adjustable. The sending frequency of the magnetron can be measured with a spectrum analyzer while the resonant frequency of the coaxial resonator can be measured by means of a network analyzer and adjusted by the movable nozzle.
To guarantee the ignition of the plasma solely by the supplied microwave, it is crucial that the resonance frequency of the coaxial resonator perfectly matches the sending frequency of the magnetron. Furthermore, the microwave has to be coupled completely into the coaxial resonator of the plasma torch assembly which is achieved by maximizing the forward power with the three stub tuner. If these critical steps are not conducted carefully it is possible that the plasma will not ignite or that the microwave is coupled into the experimental setup somewhere what could lead to some damage of these parts. Thus if no ignition of the plasma is observed, these steps have to be checked carefully again. Furthermore, it is possible that the plasma ignites but does not switch to the coaxial or cylindrical mode by itself. In this case the plasma can commonly be switched first to the coaxial mode and then to the cylindrical mode by varying the gas flow and the supplied microwave power.
To obtain a more automatic ignition and operation of the plasma an automatic three stub tuner which automatically adjusts its stubs to maximized forward power can be used instead of the manual one. Thus the adjustment of the stubs for ignition of the plasma and afterwards the adjustment for the operation of the plasma are automatically conducted by this three stub tuner. To achieve plasma ignition without any additional igniters and stable and continuous plasma operation the presented smart combination of the two resonator structures and the presented technique of the measurement of the magnetron by a spectrum analyzer and the measurement and adjustment of the resonant frequency by means of a network analyzer are crucial.
The ignition of the plasma was investigated in detail with a high speed camera. It revealed that the plasma ignites in the coaxial resonator, winds up to the tip of the nozzle burning in the coaxial mode, increases in intensity and volume, breaks away from the metallic nozzle, increases further and then burns freely above the metallic nozzle in the cylindrical mode. After the ignition of the plasma and its transition to the cylindrical mode the plasma can be operated stably and continuously. The dimension of the plasma depends on the supplied microwave power and gas flow and increases when the supplied microwave power is increased or the gas flow is decreased. Furthermore, the plasma can be shaped to needles, brushes or smooth afterglow plasmas by using orifices.
The gas flow and the microwave power of the presented microwave plasma torch are limited to about 100 slm and some kilowatts which also limits the volume of the plasma. Since the quartz tube must not be damaged the radial diameter of the plasma is limited to the inner diameter of the quartz tube. If a larger plasma volume is required or large gas flows have to be treated, the plasma source can be up-scaled by using a lower microwave frequency, for example 915 MHz instead of 2.45 GHz. With 915 MHz more microwave power is available, leading to larger plasma volumes which allow larger gas flows to be handled. However, when higher powers are used, the risk of damage, especially of the metallic nozzle, during the ignition of the plasma or during operation increases and therefore another ignition mechanism has to be considered. Furthermore, the plasma parameters, like electron and gas temperature, are independent of the outer parameters like gas flow and supplied microwave power. Thus, if an atmospheric pressure plasma with different plasma parameters is needed, a different source has to be used or one which meets the required needs has to be newly developed.
Since the presented atmospheric pressure microwave plasma torch provides ignition of the plasma without any additional igniters as well as stable and continuous plasma operation, the plasma source is suitable for many industrial applications. The advantage of the ignition of the plasma without any additional igniters for industrial processes, especially when an automatic three stub tuner is used, is that only the microwave has to be switched on and the process starts to run reliably and automatically. Furthermore, if a discontinuous operation is needed where the process is running for some time followed by intermittency, the plasma process can be restarted quickly, reliable and automatically and there is no attrition of an additional ignition system. Volume processes like chemical synthesis as well as surface treatments with the afterglow plasma can be named as applications of the microwave plasma torch. Studies on the successful degradation of harmful waste gases, especially for greenhouse gases like perfluorinated compounds which are used in the growing semiconductor industry, on the dissociation of CO2 to CO and O as well as on the pyrolysis of methane to hydrogen and carbon have already been conducted. Furthermore, the afterglow plasmas were used for the treatment of surfaces to increase the adhesion of glue and paint and for decontamination and sterilization purposes. For example, the plasma source can be used for the decontamination of the surface of cork stoppers to degrade trichloroanisole, which causes the so called cork taint. Another application is the reduction of germs on surfaces, like on packaging materials or on food.
The presented technique how the sending frequency of a high frequency power supply is measured by means of a spectrum analyzer and how the resonant frequency of a resonant structure is measured and adjusted by means of a network analyzer can also be applied to other high frequency plasma sources. As an example a tiny little micro microwave plasma jet which is based on a λ/4-resonator can be named 25–27.
Lastly, the presented movie will lead to further developments and improvements of atmospheric pressure and/or microwave plasma sources.
The authors have nothing to disclose.
The authors would like to thank the Arbeitsgemeinschaft industrieller Forschungsvereinigungen „Otto von Guericke“ e.V., AiF (German Federation of Industrial Research Associations) and the Deutsche Forschungsgemeinschaft, DFG (German Research Foundation) for partly funding the presented work under contract number 14248 and STR 662/4-1, respectively.
2 kW magnetron | Muegge | MH2000S 211BA | |
2 kW power supply | Muegge | ML2000D-111TC | |
insulator – circulator with water load | Muegge | MW1003A-210EC | |
water load | Muegge | MW1002E-260EC | |
three stub tuner | Muegge | MW2009A-260ED | |
orifices | homemade | ||
microwave plasma torch | homemade | ||
spectrum analyzer | Agilent | E4402B | |
network analyzer | Anritsu | MS4662A | |
calibration kit | Anritsu | model 3753 | |
directional coupler | homemade | ||
20 dB attenuator | Weinschee engineering | 20 dB AA57u8 | |
coaxial to rectangular wave guide transition | Muegge | MW5002A-260YD | |
adaptor 7-16 to N connector | Telegärtner | 7-16/N Adaptor | |
coaxial cable | Rosenberger Hochfrequenztechnik | LU7_070_800 | |
high speed camera | Photron | fastcam SA5 | |
lens | Revueflex | makro revuenon 1:3.5/28mm | |
local gas ventilation | Industrievertrieb Henning | ACD220 | |
UV protection glasses | uvex | HC-F9178265 | |
microwave leakage tester | conrad electronic | not available | |
microwave survey meter | Holaday industries inc. | 81273 |