Generating the Widespread Cerebral Cortical Demyelination in a Rat Model

Published: May 31, 2024

Abstract

Source: Üçal, M. et al., Rat Model of Widespread Cerebral Cortical Demyelination Induced by an Intracerebral Injection of Pro-Inflammatory Cytokines. J. Vis. Exp. (2021)

The video demonstrates a method for generating a rat model with widespread cerebral cortical demyelination. This involves disrupting the blood-brain barrier by injecting pro-inflammatory cytokines into mice primed with recombinant myelin sheath protein. This process facilitates the infiltration of immune cells, resulting in widespread cerebral cortical demyelination.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board. 1. Material Preparation NOTE: The surgery is conducted under aseptic conditions. Prior to starting, make sure that all surgical instruments, including the drill bits, are cleaned with an appropriate disinfectant. Prepare an anesthetic mixture: 0.02 mg/mL of fentanyl, 0.4 mg/mL o…

Representative Results

Figure 1: Preparation of the catheter. (A and B) The guide cannula and the dummy cannula (catheter cap with inlet) are assembled and screwed. (C) Then the catheter is cut to 2 mm in size with the help of a scalpel. The microscopic observation showed that the usage of scissors for that purpose distorts the circular shape of the cannula tip, and, t…

Offenlegungen

The authors have nothing to disclose.

Materials

Adult male Dark Agouti rats (300 ±25 g)
Fentanyl Hameln pharma plus, Germany As Fentanyl-Citrate, 50 µg/ml
Midazolam ERWO Pharma, Austria 50039017 5 mg/ml
Medetomidin Orion Pharma, Finland As Medetomidin hydrochloride, 1mg/ml
Flumazenil Roche, Switzerland 0.1 mg/ml
Atipamezol Orion Pharma, Finland As Atipamezol hydrochloride, 5 mg/ml
10% povidone-iodine complex Mundipharma, Austria
Dental cement Heraeus Kulzer, Germany 6603 7633
Physiological saline solution Fresenius Kabi, Austria 0.9% NaCl
Phosphate buffered saline (PBS) Sigma-Aldrich, Germany P3813
Isofluorane AbbVie, Austria
Lubricating eye drops Thea Pharma, Austria
70% EtOH Merck, Germany 1070172511 Absolute ethanol was diluted in ddH2O for preparation of 70% v/v
2.5% Enrofloxacin Bayer, Germany Prophylactic antibiotics
Carprofen Pfizer, USA Painkillers, 50 mg/ml
Tween-20 Sigma-Aldrich, Germany P9416
Pentobarbital Richter Pharma, Austria Pentobarbital sodium, 400 mg/ml
Interferon gamma PeproTech, USA  400-20
Tumor necrosis factor alfa R&D Systems, USA 510-RT-050/CF
rMOG1-125 own product at the Centre of Molecular Medicine, Karolinska Institute, Sweden Recombinant rat myelin oligodendrocyte glycoprotein, amino acids 1-125 from the N-terminus, also commercially available: AnaSpec, AS-55152-500, USA
Incomplete Freund’s adjuvant Sigma-Aldrich, Germany  F5506
Bovine serum albumin Sigma-Aldrich, Germany A9576
Peroxidase substrate solution Vector Laboratories, USA SK-45000
Stereotactic frame David Kopf Instruments, USA
Catheters, MRI suitable PlasticsOne, USA 8IC315GPKXXC
Dummy cannulas PlasticsOne, USA 8IC315DCNSPC
Plastic screws, MRI suitable PlasticsOne, USA 8L080X093N01
Connector cannula PlasticsOne, USA 8IC313CXSPCC
Screw driver with 2mm tip-size
Drill with flexible shaft extension Proxxon, Germany NO 28 472, NO 28 706, NO 28 620,
Drill bit, round, 0.5 mm Hager & Meisinger, Germany REF310 104 001 001 009
Drill bit, twisted, 1.3 mm Hager & Meisinger, Germany REF350 104 417 364 013
Scalpel Braun, Germany BB510
Scalpel handle Fine Science Tools, Germany 91003-12
Cotton tip applicator Henry Schein Medical, Austria 900-3155
Surgical scissors Fine Science Tools, Germany 14101-14, 14088-10
Surgical forceps Fine Science Tools, Germany 11002-12, 11251-35
Bulldog clamps Fine Science Tools, Germany 18050-35
Homoeothermic blanket TSE systems, Germany
Infrared Lamp Beurer, Germany 616.51
Dental curing light Guilin Woodpecker Medical, China
Absorbable suture Johnson & Johnson, Belgium V792E
Programmable syringe pump World Precision Instruments, USA AL-1000
Exam gloves
Surgical gown
Electric Shaver Aesculap, Germany GT420
Volatile anesthetic vaporizer Rothacher Medical, Switzerland CV 30-301-D
Oxygen source for volatile anesthetic vaporizer Air Liquide, Austria 19,113
Volatile anesthesia chamber Rothacher Medical, Switzerland PS-0347
Anesthesia mask for rats Rothacher Medical, Switzerland PS-0307-A
1 ml syringe Codan, Denmark REF 62.1612
26 Gauge needle for injection Braun, Germany 4657683
20 Gauge needle for cytokine injection and immunization Braun, Germany 4657519
Luer lock tip glass syringes Poulten & Graf, Germany 7.140-37
3 way stopcock Becton Dickinson, Sweden 394600
37°C incubator Kendro, Germany 50042301
Micropipettes Gilson, USA F167350

Tags

This article has been published
Video Coming Soon
Keep me updated:

.

Diesen Artikel zitieren
Generating the Widespread Cerebral Cortical Demyelination in a Rat Model. J. Vis. Exp. (Pending Publication), e22250, doi: (2024).

View Video