Pressure Fixation of Isolated Murine Pulmonary Valve: A Procedure to Isolate and Chemically Fix the Mouse Pulmonary Valve in Closed Conformation

Published: April 30, 2023

Abstract

Source: Liu, Y., et al. Surgery and Sample Processing for Correlative Imaging of the Murine Pulmonary Valve. J. Vis. Exp. (2021)

In this video, we describe the procedure to isolate and chemically fix the mouse pulmonary value in closed conformation via perfusion pressurization.

Protocol

All procedures involving animal models have been reviewed by the local institutional animal care committee and the JoVE veterinary review board. 1. Pulmonary valve excision Autoclave the necessary tools needed for the mouse dissection. This includes fine scissors, micro forceps, micro vascular clamps, clamp applying forceps, microneedle holders, spring scissors, and retractors. Acclimate all mice for a minimum of 2 weeks before the operation. Remove C57BL…

Offenlegungen

The authors have nothing to disclose.

Materials

25% glutaraldehyde (aq) EMS 16210 Primary fixative component
0.9% sodium chloride injection Hospira Inc. NDC 0409-4888-10
1 mL syringe BD 309659
10 mL syringe BD 309604
22G needle BD 305156
3-way stopcock Smiths Medical ASD, Inc MX5311L
4% paraformaldehyde (aq) EMS 157-4-100 Primary fixative component
C57BL/6 mice Jackson Laboratories 664 Approximately 1 yo
Clamp applying forcep FST 00072-14
Dumont #5 forcep FST 11251-20
Dumont #5/45 forceps FST 11251-35
Dumont #7 fine forcep FST 11274-20
Fine scissor FST 14028-10
Saline solution (sterile 0.9% sodium chloride) Hospira Inc NDC 0409-0138-22
Surgical microscope Leica M80
Tish needle holder/forcep Micrins MI1540
Trimmer Wahl 9854-500
Black polyamide monofilament suture, 10-0 AROSurgical instruments Corporation TI38402
Black polyamide monofilament suture, 6-0 AROSurgical instruments Corporation SN-1956
Ketamine hydrochloride injection Hospira Inc NDC 0409-2053
L-aspartic acid Sigma-Aldrich 56-84-8 Staining component
Lead nitrate EMS 17900 Staining component
Sodium cacodylate trihydrate  Sigma-Aldrich  6131-99-3  Buffer
Non-woven songes McKesson Corp. 94442000
Micro-adson forcep FST 11018-12
Millex-GP filter, 0.22 um, PES 33mm, non-sterile EMD Millipore SLGP033NS