The Virochip is a pan-viral microarray designed to simultaneously detect all known viruses as well as novel viruses on the basis of conserved sequence homology. Here we demonstrate how to run a Virochip assay to analyze clinical samples for the presence of both known and unknown viruses.
The diagnosis of viral causes of many infectious diseases is difficult due to the inherent sequence diversity of viruses as well as the ongoing emergence of novel viral pathogens, such as SARS coronavirus and 2009 pandemic H1N1 influenza virus, that are not detectable by traditional methods. To address these challenges, we have previously developed and validated a pan-viral microarray platform called the Virochip with the capacity to detect all known viruses as well as novel variants on the basis of conserved sequence homology1. Using the Virochip, we have identified the full spectrum of viruses associated with respiratory infections, including cases of unexplained critical illness in hospitalized patients, with a sensitivity equivalent to or superior to conventional clinical testing2-5. The Virochip has also been used to identify novel viruses, including the SARS coronavirus6,7, a novel rhinovirus clade5, XMRV (a retrovirus linked to prostate cancer)8, avian bornavirus (the cause of a wasting disease in parrots)9, and a novel cardiovirus in children with respiratory and diarrheal illness10. The current version of the Virochip has been ported to an Agilent microarray platform and consists of ~36,000 probes derived from over ~1,500 viruses in GenBank as of December of 2009. Here we demonstrate the steps involved in processing a Virochip assay from start to finish (~24 hour turnaround time), including sample nucleic acid extraction, PCR amplification using random primers, fluorescent dye incorporation, and microarray hybridization, scanning, and analysis.
The steps of the Virochip assay include (1) nucleic acid extraction from clinical samples, (2) reverse transcription of extracted RNA and 2nd-strand cDNA synthesis, (3) PCR amplification of randomly primed cDNA, (3) Cy3 fluorescent dye incorporation, (4) hybridization of labeled material to the Virochip microarray, and (5) scanning and analysis (Figure 1). The protocol shown below will demonstrate the use of the Virochip assay on a nasal swab sample from a child with an influenza-like illness.
Primer Sequences
Primer A 5′-GTTTCCCAGTCACGATA-(N9)-3′
Primer B 5′-GTTTCCCAGTCACGATA-3′
1. Nucleic Acid Extraction
2. Reverse Transcription and 2nd-strand CDNA Synthesis (“Round A”)
3. PCR Amplification of Randomly Primed CDNA (“Round B”)
4. Cy3 Fluorescent Dye Incorporation
5. Hybridization to Virochip Microarray
6. Virochip Scanning and Analysis
7. Representative Results:
When the protocol is done correctly, a smear should be seen on agarose gel electrophoresis after the Rd B step (Figure 2A). The Virochip microarray on the Agilent platform will be difficult to analyze visually (Figure 2B), but if a virus is present it should be readily identified by visual inspection, cluster analysis, and / or E-Predict (Figure 1C). Samples can be spiked with measured quantities of nucleic acid from a known virus (e.g. tobacco mosaic virus; MS2 bacteriophage) to serve as a positive control for the assay.
Figure 1. Schematic of Virochip microarray processing and analysis. Extracted nucleic acid from clinical samples are randomly amplified, labeled with fluorescent dyes, and hybridized to the Virochip microarray. Microarrays are scanned at 2 μm resolution and analyzed using a variety of computational tools, including E-Predict.
Figure 2. Steps in the Virochip assay. After amplification by random PCR, a smear of 200 – 1000 bp can be visualized by gel electrophoresis (A). (B) Three Virochip microarrays out of the 8 arrays / glass slide are shown, with a small region of one microarray blown-up in the inset on the bottom right corner. (C) Automated microarray viral analysis using E-Predict revealing the presence of influenza A virus in the clinical sample. The high similarity score (s=0.55) corresponds to a p-value that is close to zero, thus making this an extremely significant prediction.
The Virochip protocol as described here is complex and requires a meticulous and skilled research technician. Correct reagent concentrations and conditions for PCR, labeling, and hybridization are critical. The Virochip protocol can be easily modified to accommodate analysis of diseased tissues by use of a tissue extraction method such as TRIzol (Invitrogen) for nucleic acid extraction. Probes can be added or deleted as necessary to obtain the desired spectrum and breadth of coverage; for instance, probes for detection of nonviral targets such as bacteria and fungi can be designed and added “on-the-fly”. Some applications of the Virochip assay currently under development include broad-spectrum viral diagnostics in the clinical laboratory, outbreak investigation, purity screening of drugs and vaccines, and novel viral pathogen discovery.
The authors have nothing to disclose.
We thank David Wang, Anatoly Urisman, Amy Kistler, Kael Fischer, Patrick Tang, and Alexander Greninger for the initial development and optimization of the Virochip protocol. This work is supported by an NIH K08 grant and Abbott Discovery Award (to CC) and the Howard Hughes Medical Institute (to JLD).
Name of reagent / material | Name of reagent / material |
---|---|
PrimerA | 5′-GTTTCCCAGTCACGATA-(N9)-3′ |
Primer B | 5′-GTTTCCCAGTCACGATA-3′ |
RT Master Mix (5 μL) | 2 μL 5X RT buffer |
1 μL 12.5 mM dNTP (Invitrogen) | |
1 μL water | |
0.5 μL 0.1M DTT | |
0.5 μL SSIII RT (Invitrogen) | |
Sequenase Mix (5 μL) | 1 μL 5X Sequenase buffer |
3.8 μL water | |
0.15 μL Sequenase (USB Corporation) | |
Rd B PCR Master Mix (45 μL) | 5 μL 10X PCR buffer |
1 μL 12.5 mM dNTP (Invitrogen) | |
1 μL 100 pmol / μL primer B | |
1 μL KlenTaq LA (Sigma) | |
37 μL water | |
Rd C PCR Master Mix (45 μL) | 5 uL 10X PCR buffer |
1 μL 12.5 mM dNTP (Invitrogen) | |
1 μL 100 pmol / μL primer B | |
1 μL KlenTaq LA (Sigma) | |
37 μL water | |
Hybridization buffer (25 μL) | 1 μL 25X fragmentation buffer (Agilent) |
5 μL 5X blocking buffer (Agilent) | |
9.5 μL (or amount to normalize) of Cy3-labeled sample | |
Add water to total volume of 25 μL | |
Agilent Virochip microarray | license pending; available from Chiu laboratory, UCSF |