27G1/2" needles |
BD biosciences |
305109 |
|
30G1/2" needles |
BD biosciences |
305106 |
|
5 mL polystyrene round-bottom tube 12 x 75 mm style |
Corning |
352054 |
|
BD 1 mL Tuberculin Syringe Without Needle |
BD biosciences |
309659 |
|
BD FACS array bioanalyzer |
BD Biosciences |
|
For purity check of eluted CD34+ cells |
BD FACS array software |
BD Biosciences |
|
Software to analysis acquired CD34+ cell on FACS array |
BD FACS lysing solution |
BD Biosciences |
349202 |
To lyse red blood cells |
BD LSR II |
BD Biosciences |
|
Instrument for acquisiton of flow cytometry samples |
BD Vacutainer Plastic Blood Collection Tube |
BD biosciences |
BD 367874 |
To collect Cord blood |
Bovine Serum Albumin |
Sigma-aldrich |
A9576 |
|
CD34 MicroBead Kit, human |
Miltenyi Biotec |
130-046-702 |
For isoation of CD34+ HSPC |
CD34-PE, human |
Miltenyi Biotec |
130-081-002 |
Antibody used for purity check of eluted CD34+ cells |
Cell counting slides |
Bio-rad |
1450015 |
|
ChargeSwitch gDNA Mini Tissue Kit |
Thermofisher scientific |
CS11204 |
For extraction of genomic DNA from ear piece |
Cotton-tipped applicators |
McKesson |
24-106-2S |
|
DMSO (Dimethyl sulfoxide) |
Sigma-aldrich |
D2650-5X5ML |
|
Extension set Microbore Slide Clamp(s) Fixed Male Luer Lock. L: 60 in L: 152 cm PV: 0.55 mL Fluid Path Sterile |
BD biosciences |
30914 |
Attached to dispensing pippet and to load with HSPC and HEP suspesion |
FACS Diva version 6 |
BD Biosciences |
|
Flow cytometer software required for acqusition of sample |
Fetal Bovine Serum (FBS) |
Gibco |
10438026 |
|
FLOWJO analysis software v10.2 |
FLOWJO, LLC |
|
Flow cytometry analysis software |
Ganciclovir |
APP Pharmaceuticals, Inc. |
315110 |
Prescripition drug |
Greiner MiniCollect EDTA Tubes |
Greiner bio-one |
450475 |
|
Hepatocytes thawing medium |
Triangle Research Labs |
MCHT50 |
|
Horizon Open Ligating Clip Appliers |
Teleflex |
537061 |
To hold the ligating clips |
Human hepatocyte |
Triangle Research Labs |
HUCP1 |
Cryopreserved human hepatocytes, induction qualified |
Iris Scissors, Straight |
Ted Pella, Inc. |
13295 |
|
Lancet |
MEDIpoint |
Goldenrod 5 mm |
|
LS columns |
Miltenyi Biotec |
130-042-401 |
Used to entrap CD34+ microbeads (positive selection) |
Lymphocyte Separation Medium (LSM) |
MP Biomedicals |
50494 |
For isoation of lymphocytes from peripheral blood |
MACS MultiStand |
Miltenyi Biotec |
130-042-303 |
Holds Qudro MACS seperator and LS columns |
McPherson-Vannas Micro Dissecting Spring Scissors |
Roboz Surgical Instrument Co. |
RS-5605 |
Used to make an incision on skin to expose spleen |
Micro Dissecting Forceps |
Roboz Surgical Instrument Co. |
RS-5157 |
To hold and pull out spleen from peritoneal cavity |
Mouse CD45-FITC |
BD Biosciences |
553080 |
Mouse-specific |
PBS (Phosphate Buffered Saline) |
Hyclone |
SH30256.02 |
|
Qudro MACS separator |
Miltenyi Biotec |
130-090-976 |
holds four LS columns |
RPMI 1640 medium |
Gibco |
11875093 |
|
StepOne Plus Real Time PCR |
Applied Biosystems |
|
Instrument used to genotype |
Stepper Series Repetitive Dispensing Pipette 1ml |
DYMAX CORP |
T15469 |
Used to dispense HSPC and HEP supension in controlled manner |
TaqMan Gene Expression Master Mix |
Thermofisher scientific |
4369016 |
|
TC20 automated cell counter |
Bio-rad |
1450102 |
|
TK-NOG mice |
|
|
Provided by the Central Institute for Experimental Animals (CIEA, Japan; Drs. Mamoru Ito and Hiroshi Suemizu) |
Treosulfan |
Medac GmbH |
|
Provided by Dr. Joachim Baumgart (medac GmbH) |
Trypan Blue |
Bio-rad |
1450022 |
|
Vannas-type Micro Scissors, Straight, 80mm L |
Ted Pella, Inc. |
1346 |
Used to make an incision on skin to expose spleen |
Weck hemoclip traditional titanium ligating clips |
Esutures |
523700 |
To ligate the spleen post-injection |