This video describes the optokinetic response assay in zebrafish. The video measures the reflexive eye movements based on the visual moving stimulus and determines the visual acuity in zebrafish.
Protocol
1.Optokinetic response (OKR) Build the custom OKR recording device using a 14.5 cm diameter rotating drum, a stereo microscope with adjustable light intensity settings (300-8,000 lux) and a computer (Figure 1A). Attach a camera to the microscope that will provide a live feed onto an adjacent monitor and allow for image capture and recording. Control the rotating drum using a microcontroller linked to a computer which will accommodate various speed and direction selectio…
Representative Results
Figure 1. OKR recording. A) The OKR device consists of a 14.5 cm diameter rotating drum and microscope with adjustable light intensity settings (300-8,000 lux). A camera provides a live feed on an adjacent monitor. The rotating drum has various speed settings in both clockwise and counterclockwise directions and interchangeable spatial frequency gratings are inserted and removed as needed. …
Materials
Super Low Light Black White Video Security Camera
Super Circuits
PC164CEX-2
Any low light camera may be used
Arduino Duemilanove microcontroller
Adafruit Industries
The Arduino Uno is also compatible with the speed control software.